background image

P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-923P       Rev H       08-21       Page 6

Beep Sounds During Auxiliary Relay                    Default: No

Selects whether or not the keypad beeps during Auxiliary Relay 
activation.

Press: 42 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3                             Default: No

Selects whether or not the keypad beeps during Output #3 
activation.

Press: 43 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4                             Default: No

Selects whether or not the keypad beeps during Output #4 
activation.

Press: 44 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Keypad Lockout Count                             Default: 3 Attempts

Sets the number or incorrect entry code attempts allowed 
before the keypad “locks out” for 60 seconds.

Press: 50 # Attempts

 

 #  

Attempts=Number of attempts before lockout (2-7)

Anti-Pass Back Time

            Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is 
used.

Press: 51 # Minutes

 

 #  

Minutes=Time in minutes (2-4), 0=No Anti-passback

Beep Sounds During Main Relay                            Default:  No

Selects whether or not the keypad beeps during Main Relay 
activation.

Press: 41 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time                       Default:  02 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 24 # 

Seconds

 

 #  

Seconds=Output time in seconds (0-60), 99=Toggle Mode

Beep Sounds on Keystrokes                                   Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Selects mode for Keypad LED Backlight      Default: 30 Seconds

Selects whether or not the keypad back light stays OFF, lights for 30 
seconds when activated or stays ON.

Press: 52 # Output

 

 #  

 0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON 

Solid-state Output #3 On-time                      Default:  02 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 23 # 

Seconds

 

 #  

Seconds=Output time in seconds (0-60), 99=Toggle Mode

Beep Sounds Anti-Tamper Activation                    Default: No

Selects whether or not the keypad beeps during Anti-Tamper 
switch activation.

Press: 45 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

 Changing the

 

Beeper Sound Level

The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.

Door Ajar Timer                                         Default:  60 Seconds

Sets the amount of time the door may be held open after an 
authorized access.  The DOOR AJAR output will activate after the 
time expires.

Press: 25 # 

Seconds

 

 #  

Seconds=Held open time in seconds (1-60)

RESETTING KEYPAD

Master Reset

CAUTION:  Performing a master reset will clear the 
entire memory of the 923P and return all programmable 
options to the factory default values.  ALL ENTRY 
CODES WILL BE ERASED. NOTE:  The Master Code will 
NOT be reset.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys 
down until the red indicator starts flashing

STEP 4

Release the keys.  The red and yellow indicators will 
remain lit until the process is complete, then the 
yellow indicator will go out.

Resetting the Master Code

STEP 1

Remove the 923P from the wall and disconnect 
power from the keypad.

STEP 2 

Locate & Remove jumper at JP2.  Reference page 2.  

STEP 3

Re-apply power.  You will get a single beep and 
the yellow LED will flash momentarily.

STEP 4

Replace jumper on JP2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

Содержание EntryCheck 923P

Страница 1: ...ignal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access occurs The 923P EntryCheck is powered from a 12 or 24V AC or DC source The non volatile EEPROM memory retains entry codes and programming when power is removed An ...

Страница 2: ...ELLOW PROGRAM INDICATOR KEYPAD FRONT PROX Antenna QuickStart Programming Examples You must first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 923P EntryCheck is in programming mode Use the option codes to program each function After the new data entry is complete for each function the green indicator will light briefly if the programming ha...

Страница 3: ...orarily disabling the keypad route two wires from the switch or timer to the keypad Connect the inhibit switch timer s normally open contacts to the keypad s SENSE gray E8 and COM black wires terminal Request to Exit Input wiring shown on fig 4 If a request to exit pushbutton is going to be used route two wires from the keypad box to a normally open pushbutton mounted on the secure side of the doo...

Страница 4: ...Input Inhibit Keypad Lockout Output Disabled Keypad Active Output Disabled Beeper Sounds When Key Pressed Yes Beeper Sounds During Relay 1 No Beeper Sounds During Relay 2 No Beeper Sounds During Output 3 No Beeper Sounds During Output 4 No Keypad Lockout Count 3 Tries Before Lockout Anti Passback Time No Anti Passback Auto Relock On BASIC PROGRAMMING When the 923P EntryCheck is in Programming Mode...

Страница 5: ...ess 97 0 0 0 0 0 0 0 0 0 0 0 0 Note The green indicator will light while the memory is being erased This may take up to 15 seconds SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Erasing Multiple Users Sequential Press 09 1st User Number of users 1st User Starting user number t...

Страница 6: ... when activated default 2 Light always ON Solid state Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whether or not the keypad beeps during Anti Tamper switch activation Press 45 Sound Sound 1 for Yes 0 for No Changing the Beeper S...

Страница 7: ... 08 21 Page 7 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Rubber Gasket Metal Bracket Keypad 1 Secure metal bracket to box or wall 2 Secure keypad to metal bracket using supplied security screw Note Keypad may not conceal single gang box ...

Страница 8: ...o Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 User Employee First Name Employee Last Name 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 P INST INSTRUCTIONS ACCESS CONTROLS INST 923P Rev H 08 21 Page 8 ...