background image

WALL MOUNT

MULLION MOUNT

1.375

7.3125

1.750

4X Mount at holes
With supplied 
screws and hole 
expansion anchors

P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-923P       Rev H       08-21       Page 7

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

Rubber
Gasket

Metal
Bracket

Keypad

1.  Secure metal bracket to box or wall.
2.  Secure keypad to metal bracket using supplied security screw.

Note:  Keypad may not conceal 
single gang box.

Содержание EntryCheck 923P

Страница 1: ...ignal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access occurs The 923P EntryCheck is powered from a 12 or 24V AC or DC source The non volatile EEPROM memory retains entry codes and programming when power is removed An ...

Страница 2: ...ELLOW PROGRAM INDICATOR KEYPAD FRONT PROX Antenna QuickStart Programming Examples You must first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 923P EntryCheck is in programming mode Use the option codes to program each function After the new data entry is complete for each function the green indicator will light briefly if the programming ha...

Страница 3: ...orarily disabling the keypad route two wires from the switch or timer to the keypad Connect the inhibit switch timer s normally open contacts to the keypad s SENSE gray E8 and COM black wires terminal Request to Exit Input wiring shown on fig 4 If a request to exit pushbutton is going to be used route two wires from the keypad box to a normally open pushbutton mounted on the secure side of the doo...

Страница 4: ...Input Inhibit Keypad Lockout Output Disabled Keypad Active Output Disabled Beeper Sounds When Key Pressed Yes Beeper Sounds During Relay 1 No Beeper Sounds During Relay 2 No Beeper Sounds During Output 3 No Beeper Sounds During Output 4 No Keypad Lockout Count 3 Tries Before Lockout Anti Passback Time No Anti Passback Auto Relock On BASIC PROGRAMMING When the 923P EntryCheck is in Programming Mode...

Страница 5: ...ess 97 0 0 0 0 0 0 0 0 0 0 0 0 Note The green indicator will light while the memory is being erased This may take up to 15 seconds SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Erasing Multiple Users Sequential Press 09 1st User Number of users 1st User Starting user number t...

Страница 6: ... when activated default 2 Light always ON Solid state Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whether or not the keypad beeps during Anti Tamper switch activation Press 45 Sound Sound 1 for Yes 0 for No Changing the Beeper S...

Страница 7: ... 08 21 Page 7 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 Rubber Gasket Metal Bracket Keypad 1 Secure metal bracket to box or wall 2 Secure keypad to metal bracket using supplied security screw Note Keypad may not conceal single gang box ...

Страница 8: ...o Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 User Employee First Name Employee Last Name 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 P INST INSTRUCTIONS ACCESS CONTROLS INST 923P Rev H 08 21 Page 8 ...