10.2  Door Relay, Door Open Detection, Alarm, Facility code Settings

Door relay time setting

To disable door open detection.
 (Factory default setting)

 6   0   # 

To enable door open detection

 6     2     # 

Keypad Lockout

Alarm Output

To remove the alarm

To reset the Door Forced  Open warning

Normal status: No keypad lockout
 or alarm

 7   0   # (Factory default setting)

 7   1   # 

 7   2   # 

 Read valid card

 or 

Master Code #

To add and delete users in card and PIN mode (   3   1   #   )

.7.

.8.

To exit from the programming mode

To change the master code

To add a 

PIN

 user 

*     

Master code     

888888 is the default factory master code

To enter the programming mode

*     

No te that to un dertake the followi ng pr ogrammi ng the ma ster us er mus t be logged in

The master code is any 6 digits

The ID number is any number between 1 ~ 2500. 
The PIN is any four digits between 0000 ~ 9999 
with the exception of 1234 which is reserved. 
Users can be added continuously without exiting
programming mode

W1/W3-B Quick Reference Programming Guide

To add a 

card

 user 

Cards can be added continuously without 
exiting from programming mode

To delete a 

PIN

 or a 

card

 user 

Users can be deleted continuously without 
exiting from programming mode

1    Read Card    #

Present the card 

To Unlock the door

Waterproof

 

Keypad/Reader/Controller

To Add a 

card

 and 

Pin

 user

(The PIN is any four digits between 
0000  ~  9999  with  the  exception  of 
1234 which is reserved.)

To  change  a 

PIN 

in  card  and  PIN 

mode  (Method  1)  Note  that  this  is 
done  outside  programming  mode

 

so  the  user  can  undertake  this 
themselves

To  change  a 

PIN 

in  card  and  PIN 

mode  (Method  2)  Note  that  this  is 
done  outside  programming  mode

 

so  the  user  can  undertake  this 
themselves

To delete a 

Card and

 

PIN 

user just 

delete the card

*  Read Card  Old PIN #   New PIN #   New PIN #

*  ID number#  Old PIN #  New PIN #  New PIN #

2  User ID   #

To add a card user in card only mode         (  3    0   #   )

To Add and Delete a 

card

 user

The operating is the same as adding and deleting 
a card user in 3   2   #

To delete All users

To add and delete card users by Manager cards

To  delete

  ALL  users. 

Note  that 

this  is  a 

dangerous

  option  so  use 

with care

To add card user by Manager Add

 

Card

To  delete  card  User  by

 

Manager

 

Delete Card

2   0000   #

Manager add card   Read card  Manager add card  
Cards can be added continuously.

Manager delete card    Read Card   Manager delete card   
Cards can be deleted continuously.

Enter the PIN  then press #

For a 

card

 user

Read card

For a 

card and PIN

 user

Read card then enter PIN #

Door relay time setting

4   0~99   #
The door relay time is between 0~99 seconds,
 the factory default setting is 5 seconds.

Door Open Detection 

Door Open Too Long (DOTL) warning

. When used with an optional magnetic contact 

or built-in magnetic contact of the lock, if the door is opened normally, but not closed 
after 1 minute, the inside buzzer will beep automatically to remind people to close 
the door and continue for 1 minute before switching off automatically.

Door Forced Open warning. 

When used with an optional magnetic contact or built-in 

magnetic contact of the lock, if the door is forced open, or if the door is opened after 
20  seconds  of  the  electro-mechanical  lock  not  closed  properly,  the  inside  buzzer 
and alarm output will both operate. The Alarm Output time is adjustable between 0-3 
minutes with the default being 1 minute.

Alarm output time

To set the alarm output time (0~3
minutes) Factory default is 1 minute 

9   0

3   #

Keypad  Lockout  &  Alarm  Output  options

.  If  there  are  10  invalid  cards  or  10 

incorrect  PIN  numbers  in  a  10  minute  period  either  the  keypad  will  lockout  for  10 
minutes or the alarm will operate for 10 minutes, depending on the option selected 
below.

To reset the Door Open Too Long warning

To se t the facility co de

Close the door 

or 

 Read vali d card

 or  

Master Code #

To set the facility code of W1/W3-
B
(This operation might be required 
w h e n  W 1 / W 3 - B  i s  a c t i n g  a s 
wiegand reader and connecting to 

8   Facility code   #   Repeat Facility code  #
Facility  Code  can  be  any  number  between 
1~255   (Default: 0)

11 Interconnecting Two Devices 

11.1 W1/W3-B operating as a Wiegand Output Reader

In this mode the W1/W3-B supports a Wiegand 26 bit output so the Wiegand data lines 
can be connected to any controller which supports a Wiegand 26 bit input. See figure 1.

D0

D1

ALARM-

OPEN

D_IN

W1/W3-B

GND

AC&DC

AC&DC

NC

COM

NO

Controller

V+

V+

GND

GND

D0

D1

Power

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

Pink

(With Wiegand 26 inPut)

Transmission Format:

 1: Keypad Transmission 

The Reader will transmit the PIN data when it receives the last key (#) press after 
PIN code.

Format:

 Facility Code + PIN Code 

(Facility code is any digits between 0~255, factory default is 0; Pin code is any 1~4 
digits between 0~9999)

Example:

 Facility code: 1

                  PIN code: 5678
Press 5678 #, then the output format will be: 00105678

 2: Proximity Card Transmission 

The Reader will transmit the card data when it reads the Card.

Format:

 Card Number (the last 8 digits of Card Number)

Remarks: 

No matter the card or pin is valid or invalid, the data will be transmitted

11.2  W1/W3-B operating as a Controller

In  this  mode  the  W1/W3-B  supports  a  Wiegand  26  bit  input  so  an  external  Wiegand 
device  with  a  26  bit  output  can  be  connected  to  the  Wiegand  input  terminals  on  the 
W1/W3-B.  Either  an  ID  card  reader  (125KHZ)  or  an  IC  card  reader  (13.56MHZ)  can 
be connected to the W1/W3-B. Cards are required to be added at the external reader, 
except where an external EM reader is used, in this case cards can be added at either 
reader or controller. See figure 2.

D0

D0

D1

D1

ALARM-

OPEN

D_IN

 DC

/3A

12 V

W1/W3-B

Door detecting switch

-

-

+

+

-

+

Special Power Supply

Alarm

GND

AC&DC

AC&DC

NC

COM

NO

NC

COM NO +12V GND

V+

GND

OPEN

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

Pink

Exit button

Wiegand reader

Fail-Secure lock

Fail-Secure lock

1    User ID number      #     PIN    # 

Add the card as for a card user 

Press 

 *

  to 

exit from the

 

programming mode

Then allocate the card a PIN as

 

follows:

*    Read Card    1234 #   PIN #   PIN #