User manual
.9.
.10.
1
2
3
4
5
6
7
8
9
0
#
For a
PIN
user
To unlock the door
10.2 Door Relay, Door Open Detection, Alarm, Facility code Settings
Door relay time setting
To disable door open detection.
(Factory default setting)
6 0 #
To enable door open detection
6 2 #
Keypad Lockout
Alarm Output
To remove the alarm
To reset the Door Forced Open warning
Normal status: No keypad lockout
or alarm
7 0 # (Factory default setting)
7 1 #
7 2 #
Read valid card
or
Master Code #
To add and delete users in card and PIN mode ( 3 1 # )
.7.
.8.
To exit from the programming mode
To change the master code
To add a
PIN
user
*
Master code
#
888888 is the default factory master code
To enter the programming mode
*
No te that to un dertake the followi ng pr ogrammi ng the ma ster us er mus t be logged in
The master code is any 6 digits
The ID number is any number between 1 ~ 2500.
The PIN is any four digits between 0000 ~ 9999
with the exception of 1234 which is reserved.
Users can be added continuously without exiting
programming mode
W1/W3-B Quick Reference Programming Guide
To add a
card
user
Cards can be added continuously without
exiting from programming mode
To delete a
PIN
or a
card
user
Users can be deleted continuously without
exiting from programming mode
1 Read Card #
Present the card
To Unlock the door
Waterproof
Keypad/Reader/Controller
To Add a
card
and
Pin
user
(The PIN is any four digits between
0000 ~ 9999 with the exception of
1234 which is reserved.)
To change a
PIN
in card and PIN
mode (Method 1) Note that this is
done outside programming mode
so the user can undertake this
themselves
To change a
PIN
in card and PIN
mode (Method 2) Note that this is
done outside programming mode
so the user can undertake this
themselves
To delete a
Card and
PIN
user just
delete the card
* Read Card Old PIN # New PIN # New PIN #
* ID number# Old PIN # New PIN # New PIN #
2 User ID #
To add a card user in card only mode ( 3 0 # )
To Add and Delete a
card
user
The operating is the same as adding and deleting
a card user in 3 2 #
To delete All users
To add and delete card users by Manager cards
To delete
ALL users.
Note that
this is a
dangerous
option so use
with care
To add card user by Manager Add
Card
To delete card User by
Manager
Delete Card
2 0000 #
Manager add card Read card Manager add card
Cards can be added continuously.
Manager delete card Read Card Manager delete card
Cards can be deleted continuously.
Enter the PIN then press #
For a
card
user
Read card
For a
card and PIN
user
Read card then enter PIN #
Door relay time setting
4 0~99 #
The door relay time is between 0~99 seconds,
the factory default setting is 5 seconds.
Door Open Detection
Door Open Too Long (DOTL) warning
. When used with an optional magnetic contact
or built-in magnetic contact of the lock, if the door is opened normally, but not closed
after 1 minute, the inside buzzer will beep automatically to remind people to close
the door and continue for 1 minute before switching off automatically.
Door Forced Open warning.
When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is forced open, or if the door is opened after
20 seconds of the electro-mechanical lock not closed properly, the inside buzzer
and alarm output will both operate. The Alarm Output time is adjustable between 0-3
minutes with the default being 1 minute.
Alarm output time
To set the alarm output time (0~3
minutes) Factory default is 1 minute
9 0
~
3 #
Keypad Lockout & Alarm Output options
. If there are 10 invalid cards or 10
incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10
minutes or the alarm will operate for 10 minutes, depending on the option selected
below.
To reset the Door Open Too Long warning
To se t the facility co de
Close the door
or
Read vali d card
or
Master Code #
To set the facility code of W1/W3-
B
(This operation might be required
w h e n W 1 / W 3 - B i s a c t i n g a s
wiegand reader and connecting to
8 Facility code # Repeat Facility code #
Facility Code can be any number between
1~255 (Default: 0)
11 Interconnecting Two Devices
11.1 W1/W3-B operating as a Wiegand Output Reader
In this mode the W1/W3-B supports a Wiegand 26 bit output so the Wiegand data lines
can be connected to any controller which supports a Wiegand 26 bit input. See figure 1.
D0
D1
ALARM-
OPEN
D_IN
W1/W3-B
GND
AC&DC
AC&DC
NC
COM
NO
Controller
V+
V+
GND
GND
D0
D1
Power
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
(With Wiegand 26 inPut)
Transmission Format:
◆
1: Keypad Transmission
The Reader will transmit the PIN data when it receives the last key (#) press after
PIN code.
Format:
Facility Code + PIN Code
(Facility code is any digits between 0~255, factory default is 0; Pin code is any 1~4
digits between 0~9999)
Example:
Facility code: 1
PIN code: 5678
Press 5678 #, then the output format will be: 00105678
◆
2: Proximity Card Transmission
The Reader will transmit the card data when it reads the Card.
Format:
Card Number (the last 8 digits of Card Number)
Remarks:
No matter the card or pin is valid or invalid, the data will be transmitted
11.2 W1/W3-B operating as a Controller
In this mode the W1/W3-B supports a Wiegand 26 bit input so an external Wiegand
device with a 26 bit output can be connected to the Wiegand input terminals on the
W1/W3-B. Either an ID card reader (125KHZ) or an IC card reader (13.56MHZ) can
be connected to the W1/W3-B. Cards are required to be added at the external reader,
except where an external EM reader is used, in this case cards can be added at either
reader or controller. See figure 2.
D0
D0
D1
D1
ALARM-
OPEN
D_IN
DC
/3A
12 V
W1/W3-B
Door detecting switch
-
-
+
+
-
+
Special Power Supply
Alarm
GND
AC&DC
AC&DC
NC
COM
NO
NC
COM NO +12V GND
V+
GND
OPEN
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Exit button
Wiegand reader
Fail-Secure lock
Fail-Secure lock
1 User ID number # PIN #
Add the card as for a card user
Press
*
to
exit from the
programming mode
Then allocate the card a PIN as
follows:
* Read Card 1234 # PIN # PIN #
W1-B
W3-B