INTRODUCTION
Function
ANSI Code
IEC61850
Logical Node
XMR-A
4I+1V/1A
XMR-V
4V
XMR-P
4I+4V
XMR-D
4I+4V
(4I+64F)
XMR-T 8I+1V
XMR-T PRO
11I+1V
Under Impedence
21
PDIS - F21Sn
Over Flux(V/Hz)
24
PVPH - F24 Sn
L
SynchroCheck
25
RSYN - F25 State
GGIO - F25 Management
Thermal with Pt100 Probes
26
PTTR - F26 Sm
Under Voltage
27
PTUV - F27 Sn
Positive Sequence Undervoltage
27V1
PTUV - F27V1
100%Stator earth fault with 3
rd
harmonic
27H - 59H
Directional active overpower
32P
PDOP - F32Pn
Directional reactive overpower
32Q
PDOP - F32Qn
Under Current
37
PTUC - F37H1 - F37L1
L, H, T
Directional active underpower
37P
PDUP - F37Pn
Directional reactive underpower
37Q
PDUP - F37Qn
Loss of Field
40(M/G)
PDUP - F40Sn
Negative sequence overcurrent transformer
46LT
PTOC - F46Hn - F46Ln
L, H, T
Negative sequence overcurrent Motor/Generator
46M, 46G
PTOC - F46GSA - F46GS1
Negative /positive sequence current ratio
I2/I1
PTOC - FI21L- FI21H
L, H, T
Phase reversal
47
PTOV - F47 Us1
Thermal Image Transformer
49LT
PTTR - F49H1- F49L1
L, H, T
Thermal Image Motor/Generator
49MG
PTTR - F49MS1
Unintentional energisation at standstill protection
50/27
GGIO- SPV
Phase overcurrent side H and side L
50/51
PTOC - F51Lp - F51Hp
L, H, T
Maximum Residual Overcurrent
50N/51N
PTOC - F5N1p - F5N2p
L, H, T
Maximum Residual Overcurrent(2)
50N/51N(2)
PTOC - F5N1p - F5N2p
Calculated Residual Overcurrent
50N/51N(Comp)
PTOC - F5NLp - F5NHp
Locked Rotor
51LR(48)/14
PMSS - F51Rn
Voltage restraint overcurrent
51V
PTOC - F51Vn
Minimum Power Factor
55
PUPF - F55Sn
Overvoltage
59
PTOV - F59Sn
Residual Overvoltage
59N
PTOV - F59Np
Negative sequence overvoltage
59V2
PTOV - F59V2
Rotor Earth Fault
64F
PTOC - F64Fn
Low impedance restricted earth fault
64REF
PHIZ - F64F1
1, 2
Maximum number of startings (Restart inhibition)
66
PMRI - F66S1
Phase Directional Overcurrent
(Voltmetric Permission)
67
PTOC - F67Sq
RDIR - F67Sq
Ground directional overcurrent
67N
PTOC - F67Nw
RDIR - F67Nw
PTOV - F67Nw
PTOC - F67N6 Intermittent
PTOC - F67N7 Evolutionary
Ground directional overcurrent with calculated
residual current
67N(Comp)
PTOC - F67NCq
RDIR - F67NCq
PTOV - F67NCq
Out of Step Protection
78
PPAM - F78A - F78B
Automatic Recloser
79
RREC - F79
Vector Jump
DPHI
GGIO- SPV
Over frequency
81O
PTOF - F81Oq
Under frequency
81U
PTUF - F81Uq
Frequency rate Change
81R
PFRC - F81Rq
Lock-out
86
Double slope biased differential for Generator/
Motor/Transformer
87M-G-T
PHAR - F87Hw
Breaker Failure
BF
RBRF
L, H, T
CT Supervision
74CT
GGIO- SPV
L, H
VT Supervision
74VT
GGIO- SPV
Trip Circuit Supervision
74TCS
SCBR - 74TCSH - 74TCSL
Remote TRIP
2
nd
h-REST
PHAR - FI2S1L - FI2S1H
ARC FLASH
Multiple Profiles (A, B)
Multiple Profiles (A, B, C, D)
Optional with requested HW Expansion
Threshold key n (1,2) - m (1,2,3,4,5,6) - p (1,2,3) - q (1,2,3,4) - w (1,2,3,4,5)
Optional with requested SW Package
Standard
Work in Progress
XMR-D EQUIPMENT MANUAL