APPENDIX
379
8.2
APPENDIX A2 - PROTECTION FUNCTIONS
Standard Protective & control elements
SW Pack optional configuration
Protection function Work in Progress
21
Distance relay
24
Overflux (V/Hz)
25
Synchrocheck
26
Pt100 thermal probes
27 Undervoltage
27V1
Positive sequence undervoltage
27H-59H
100% stator earth-fault with 3
rd
harmonic
32P
Directional active overpower
32Q
Directional reactive overpower
37 (L - H)
Undercurrent (Side L - Side H)
37P
Directional active underpower
37Q
Directional reactive underpower
40(M/G)
Loss of excitation
46(L - H)
Negative sequence overcurrent (Side L - Side H)
46(M/G)
Negative sequence overcurrent
I2/I1 (L - H)
Negative/positive sequence current ratio (Side L - Side H)
47
Phase reversal
49(L -H)
Thermal image (Side L - Side H)
49(M/G)
Thermal image
50/27
Inadvertent energigization
50/51 (L - H)
Phase overcurrent (Side L - Side H)
50N/51N/87NHIZ .1*
Residual overcurrent/Restricted earth fault
50N/51N/87NHIZ .2*
Residual overcurrent/Restricted earth fault
50N/51N (L - H)
Calculated residual overcurrent (Side L - Side H)
51LR(48)/14
Locked rotor
51V
Phase overcurrent voltage restrain
55
Minimum power factor
59 Overvoltage
59N
Residual overvoltage
59V2
Negative sequence overvoltage
64F
Rotor earth fault
64REF
Low impedance restricted earth fault
66
Maximum number of starting
67(Volt. Cons.)
Phase directional overcurrent
67N
Ground directional overcurrent
67N(Comp)
Ground directional overcurrent with calculated
residual current
78
Out of step
DPHI
Vector jump
81O/81U
Overfrequency and underfrequency
81R
Frequency rate of change
87G-87M/87T
Double slope biased differential for generator/motor/transformer
2nd -REST (L -H)
Second harminic restrain (Side L - Side H)
BF (L - H)
Circuit breaker failure (Side L - Side H)
74VT
VT supervision
74CT (L- H)
CT supervision (Side L - Side H)
74TCS(L H)
Trip circuit supervision (Side L - Side H)
86
Lock-out
ArcFlash
ArcFlash
U
L1
,
U
L2
,
U
L3
I
L1-H
,
I
L2-H
,
I
L3-H
I
L1-L
,
I
L2-L
,
I
L3-L
U
E
U
E
U
EC
U
E
U
EC
I
ECH
I
ECH
I
ECL
74CT
81U
50/51
81O
59
27V1
27
40
51V
46
49
47
37P/Q
37
21
87G
87T
59V2
74TCS
BF
I
E-1
26
*
*
52
G
64REF
U
EC
I
ECH
I
ECL
50N/51N(Comp)
I
E-2
50N.2/51N.2
87NHIZ
50N.1/51N.1
59N
67N
67N(Comp)
74VT
74CT
50/51
I
ECH
I
ECL
I
L1-L
,
I
L2-L
,
I
L3-L
I
L1-H
,
I
L2-H
,
I
L3-H
74VT
81U
81O
59
27V1
27
46
49
55
37P/Q
37
32P
87M
59V2
74TCS
26
52
M
40
51LR
50/51
66
74CT
74CT
BF
U
L1
,
U
L2
,
U
L3
U
E
U
E
U
EC
59N
*
87NHIZ
I
E2
I
ECH
I
ECL
50N/51N(Comp)
U
E
U
EC
67N
U
E
U
EC
I
ECH
I
ECL
67N(Comp)
50N.2/51N.2
50/51
12
12
24
24
25
25
50/27
67
67
64F
78
64F
78
81R
81R
XMR-
D
XMR-
D
86
86
XMR-D EQUIPMENT MANUAL
Ed. 2.9 - 02/2021