C-Link Protocol Commands
Commands
Thermo Fisher Scientific
Model 146
i
Instruction Manual
B-3
Command
Description
Page
alarm bench lamp
temp min
Reports/sets photometer bench lamp temperature alarm
minimum value
B-10
alarm bench temp
max
Reports/sets photometer bench temperature alarm maximum
value
B-11
alarm bench temp
min
Reports/sets photometer bench temperature alarm minimum
value
B-11
alarm conc o3 max
Reports/sets photometer O
3
concentration alarm maximum
value
B-11
alarm conc o3
min
Reports/sets photometer O
3
concentration alarm minimum
value
B-11
alarm intensity max
Reports/sets photometer intensity alarm maximum value
B-11
alarm intensity min
Reports/sets photometer intensity alarm minimum value
B-11
alarm internal temp
max
Reports/sets ambient temperature alarm maximum value
B-12
alarm internal temp
min
Reports/sets ambient temperature alarm minimum value
B-12
alarm o3 lamp temp
max
Reports/sets ozonator lamp temperature alarm maximum
value
B-12
alarm o3 lamp temp
min
Reports/sets ozonator lamp temperature alarm minimum
value
B-12
alarm pressure max
Reports/sets photometer pressure alarm maximum value
B-13
alarm pressure min
Reports/sets photometer pressure alarm minimum value
B-13
alarm trig conc o3
Reports/sets O
3
concentration low alarm trigger value
B-13
analog iout range
Reports/sets analog current output range per channel
B-43
analog vin
Retrieves analog voltage input data per channel
B-43
analog vout range
Reports/sets analog voltage output range per channel
B-44
avg time
Reports/sets averaging time
B-8
baud
Reports/sets baud rate
B-40
cal o3 bkg
Sets/auto-calibrates O
3
background
B-23
cal o3 coef
Sets/auto-calibrates O
3
coefficient
B-23
clr lrecs
Clears away only long records that have been saved
B-16
clr records
Clears away all logging records that have been saved
B-16
clr srecs
Clears away only short records that have been saved
B-16
contrast
Reports/sets current front-panel screen contrast
B-37
copy lrec to sp
Copies current lrec selection into the scratch pad
B-21
copy sp to lrec
Copies current selections in scratch pad into lrec list
B-21
copy sp to srec
Copies current selections in scratch pad into srec list
B-21
Содержание 146i
Страница 1: ...Model 146i Instruction Manual Dynamic Gas Calibrator Part Number 102482 00 30Jan2008 ...
Страница 4: ......
Страница 16: ...Contents xii Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 148: ......
Страница 188: ...Troubleshooting Service Locations 6 26 Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 258: ...System Description I O Components 8 16 Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 272: ...9 14 Model 146i Instruction Manual Thermo Fisher Scientific Figure 9 4 Rack Mount Option Assembly ...
Страница 273: ...Thermo Fisher Scientific Model 146i Instruction Manual 9 15 Figure 9 5 Bench Mounting ...
Страница 274: ...9 16 Model 146i Instruction Manual Thermo Fisher Scientific Figure 9 6 EIA Rack Mounting ...
Страница 275: ...Thermo Fisher Scientific Model 146i Instruction Manual 9 17 Figure 9 7 Retrofit Rack Mounting ...
Страница 276: ...Optional Equipment Mounting Options 9 18 Model 146i Instruction Manual Thermo Fisher Scientific ...