C-Link Protocol Commands
Commands
Thermo Fisher Scientific
Model 146
i
Instruction Manual
B-5
Command
Description
Page
gas solenoid
Reports/sets solenoid used when gas selected
B-29
gas span
Selects gas span level 0, 1, 2, 3, 4, or 5
B-30
gas span conc
Reports/sets target concentration for specified gas and span
level
B-30
gas span flow
Reports/sets target total flow for specified gas and span
level
B-31
gas tank conc
Reports/sets concentration of cylinder connected as specified
gas
B-31
gflow
Reports flow through gas flow controller
B-8
he (help)
Simulates pressing help pushbutton
B-25
host name
Reports/sets host name string for Ethernet port
B-41
instr name
Reports instrument name
B-42
instrument id
Reports/sets instrument id
B-42
intensity
Reports photometer detector intensity in Hz
B-9
intern temp
Reports current internal instrument temperature
B-15
isc (iscreen)
Retrieves framebuffer data used for the display
B-26
l1
Reports/sets custom level 1 setting of ozonator lamp drive
B-32
l1 conc
Reports/sets custom level 1 concentration for photometer
control of ozonator lamp drive
B-32
l2
Reports/sets custom level 2 setting of ozonator lamp drive
B-32
l2 conc
Reports/sets custom level 2 concentration for photometer
control of ozonator lamp drive
B-32
l3
Reports/sets custom level 3 setting of ozonator lamp drive
B-32
l3 conc
Reports/sets custom level 3 concentration for photometer
control of ozonator lamp drive
B-32
l4
Reports/sets custom level 4 setting of ozonator lamp drive
B-32
l4 conc
Reports/sets custom level 4 concentration for photometer
control of ozonator lamp drive
B-32
l5
Reports/sets custom level 5 setting of ozonator lamp drive
B-32
l5 conc
Reports/sets custom level 5 concentration for photometer
control of ozonator lamp drive
B-32
lamp
Reports/sets photometer lamp drive setting
B-23
lamp setting
Reports photometer lamp drive setting
B-24
lamp temp
Reports photometer lamp temperature
B-15
lamp voltage bench
Reports photometer bench lamp voltage in volts
B-15
lamp voltage o3
Reports ozonator lamp voltage in volts
B-15
Содержание 146i
Страница 1: ...Model 146i Instruction Manual Dynamic Gas Calibrator Part Number 102482 00 30Jan2008 ...
Страница 4: ......
Страница 16: ...Contents xii Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 148: ......
Страница 188: ...Troubleshooting Service Locations 6 26 Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 258: ...System Description I O Components 8 16 Model 146i Instruction Manual Thermo Fisher Scientific ...
Страница 272: ...9 14 Model 146i Instruction Manual Thermo Fisher Scientific Figure 9 4 Rack Mount Option Assembly ...
Страница 273: ...Thermo Fisher Scientific Model 146i Instruction Manual 9 15 Figure 9 5 Bench Mounting ...
Страница 274: ...9 16 Model 146i Instruction Manual Thermo Fisher Scientific Figure 9 6 EIA Rack Mounting ...
Страница 275: ...Thermo Fisher Scientific Model 146i Instruction Manual 9 17 Figure 9 7 Retrofit Rack Mounting ...
Страница 276: ...Optional Equipment Mounting Options 9 18 Model 146i Instruction Manual Thermo Fisher Scientific ...