To install the luminaire follow the installation
instructions
ο
n page 3.
o
These luminaires are used indoors
(
ta 40 C
)
where emergency light is needed. Each
luminaire must be permanently connected to
mains power supply
.
In normal operation the
power
and
charge
indicators are on to indicate
that the batteries are charging. In case of a
mains power supply failure the
power
and
the
charge
indicators turns off and the
l u m i n a i r e w i l l l i g h t t h e s p o t l a m p s
automatically in emergency mode. When the
mains power supply is restored the device
turns to normal operation.
INSTALLATION
OPERATION
When the device is powered from the mains
and the battery(ies)
is (are) connected, the
‘power’ and ‘charge’ indicators are ON. The
‘charge’ indicator indicates the battery charging
operation.
If
it does
not li
gh
t, probably, the
batter
ies are
disconnected. If
it does
not li
gh
t
and the batter
ies
are
connected, then contact
the technician. The
power
indicator confirms
the
proper connection to the
mains
. The
TEST
butto
n, has a dual use. If pressed
instantlly
while the device is
connected to the mains
, the
GENERAL
When
the luminaire is in emergency mode
, with
corresponding press
ing
s of the button,
we ca
n
choose
the illumination of 100%, 50%, 33%
or
turned off
,
in order to increase the autonomy
duration
. This option is canceled when the
network is restored.
DIMMING OPTION
device simulates the
power interruption
,
by
lighting
the
lamps for
3
''. In th
at
way
,
we can
control the driver circuit of
the lamps
and
the
lamps as indicated in paragraph
3
in
the text
below.
Page
1
from
3
GRL-22
``POWER LIGHT`` SERIES NON-MAINTAINED EMERGENCY LUMINAIRE
923022100_09_007
ABS/PC, PC
TECHNICAL CHARACTERISTICS
(
for LED MODULE Specs. see page 2)
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Pb)
CHARGING TIME
INDICATIONS
-
CONTROLS
BATTERY PROTECTION
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
EMERGENCY ILLUMINATION
LIGHT SOURCE
<24h
Power indicator, battery charge indicator, TEST button
From overcharge and deep discharge
IP42
o
5 to 40 C
Up to 95%
3 years
(1
year for the battery
)
White LEDs
EN 60598-1, EN 60598-2-22
, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
302 x 103 x 230 mm
220-240V AC/50-60Hz
600 min
12V/7Ah
710lm
16VA
3400gr.
Thank you for your trust in our products
Olympia Electronics - European manufacturer