3-23
CANNON
XLR 32F
DC IN
AC FUSE
T4A
DC BREAKER
RAL / HLD
9.6 / 19.2
TRG S/M
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
SELECTOR
AC IN
STAND BY
OPTION SLOT 1
OUTPUT
1
2
3
4
5
6
7
8
220V
240V
8 7 6 5 4 3 2 1
!
PTRG OFF/ON
!
Power Supply Block
1
STAND BY switch
Used to turn power for the main functions of the recorder on and off.
Note
The battery pack charging function is valid regardless of the STAND BY switch
position, if the AC power is connected.
2
AC IN connector
Used to supply external AC power to the recorder. Connect the supplied AC power cord.
!
CAUTION
Be sure to supply voltage within the specified range.
3
AC voltage selector switch
Used to switch the AC voltage between 100/120 V (allowable range 90 to 132 V) and
220/240 V (allowable 198 to 250 V), according to the local AC voltage.
!
CAUTION
•
Be sure to set the voltage selector switch to the voltage range you intend to use.
•
The AC power cord has a safety earth. Be sure to connect the power cord to an earthed
socket.
4
AC fuse
This fuse is used to protect the AC power system.
!
CAUTION
For continued protection against risk of fire, replace only with fuse of the specified type
and current ratings.
Be sure to disconnect the AC power cord when replacing the fuse.
5
DC IN connector
Used to supply external DC power to the recorder. Connect the supplied DC power cord.
!
CAUTION
Be sure to supply voltage (DC 11 to 30 V) within the specified range.
2
1
3
4
7
5
6