4-10
4-4 Error Codes
When the recorder malfunctions during self-check, calibration, recording or playback
operation, the error codes shown below appear in the bar meter area. Take the appropriate
actions in accordance with the corresponding explanations.
In addition, when using the recorder in a dusty surrounding, the data could not be played
back (or verified during recording) and also an error code (ET03) is displayed.
In such a case, perform a play back inside a room.
If the error is not remedied after the appropriate action has been taken or if the displayed
error code is not listed in this manual, contact service engineer.
Note
When the power cannot be turned ON even if the standby switch is set to ON or when the
key is inoperative, set the standby switch to OFF, disconnect the power cord, then connect
the power cord again.
How to care
Consult with service engineer
Replace the battery with new one
Operate in the allowable environmental temperature
Supply DC voltage within allowable range
Input proper commands
Confirm connection of the remote control unit
Stop the recorder and put the mode again
Confirm connection of the extension cable
Confirm the power to the expansion unit
Consult with service engineer
Consult with service engineer
Disconnect the power cord then connect it back
Consult with service engineer
Consult with service engineer
Confirm setting of the channel mode and tape speed
Confirm existence of the SBS-10A/S board
when playing back the tape in digital mode
Consult with service engineer
Consult with service engineer
Be sure not to put the same SCX ID number
Confirm connection of the extension cable
Confirm the power to the expansion unit
Consult with service engineer
Location
Power Supply
System controller/
digital signal
processor
Power Supply
Analog system
Error Code
EP03
EP11
EP30
EP31
Ed20
Ed30
Ed40
Ed50
Ed60
Ed70
EA20
EA30
EA40
EA50
EA60
EA70
EA80
Abnormality
Power failure
Battery charge error
DC/DC converter overheat
SCX-32 low voltage
RS-232C communication error
Remote control unit communication error
Synchronized operation communication error
Analog communication error
DSP communication error
Power communication error
Recording system CAL error
Playback system CAL error
No playback error
ADA board version error
ADA flash memory error
SCX ID error
ADA board error