12-15
Command
Contents
MOD?
Tape transport mode read
Command format
MOD? /[ ]
Returned format
MOD:<1><2>
<1>: 0 = STOP, 1 = FWD, 2 = E-E, 3 = REC, 4 = FWD-PAUSE, 5 = REC-PAUSE, 6 = FF,
7 = RSV, 8 = REW, 9 = RSV, A = EJECT
<2>: S = During STOP transition
P = During PAUSE transition
0 = The end of transition
F = During FWD Transition (Only sync mode)
Related command: MOD
MON?
Monitor channel setting read
Command format
MON? /[ ]
Returned format
MON:<1><2>
<1>: Channel expansion unit ID number
<2>: Channel code
0 = Recorder
0 = CH 1
1 = Unit ID 1 (SIR-1000/1000i)
1 = CH 2
2 = Unit ID 2 (SIR-1000/1000i)
2 = CH 3
3 = Unit ID 3 (SIR-1000/1000i)
3 = CH 4
4 = Unit ID 4 (SIR-1000/1000i)
4 = CH 5
5 = Unit ID 5 (SIR-1000/1000i)
5 = CH 6
6 = Unit ID 6 (SIR-1000/1000i)
6 = CH 7
7 = Unit ID 7 (SIR-1000/1000i)
7 = CH 8
8 = CH 9
9 = CH 10
A = CH 11
B = CH 12
C = CH 13
D = CH 14
E = CH 15
F = CH 16
Related command: MON
OFA?
Auto offset setting status
Command format
OFA? <1>/[ ]
<1>: Channel expansion unit ID number (0 = Recorder)
Returned format
OFA:<1>
<1>: 0 = Auto offset setting finished, 1 = Auto offset setting underway
Related command: OFA
OFS?
DC offset value read
Command format
OFS? <1><2>/[ ]
<1>: 0 = Recorder setting value, 1 = Tape data
<2>: Channel expansion unit ID number (0 = Recorder)
Returned format
OFS:<1><2>...<32>
<1><2>: CH 1 DC offset (2-digit hexadecimal 2’s complement display)
<3><4>: CH 2 DC offset (2-digit hexadecimal 2’s complement display)
<31><32>: CH 16 DC offset (2-digit hexadecimal 2’s complement display)
Related command: OFS
.
.
.