background image

TOUCH SCREEN PAPERLESS RECORDER

 

            

www.accsyselectronics.com

 

 

Page 1  

 

 

 

USER MANUAL 

M

U

L

T

I

 

C

O

L

O

R

 

TOUCH SCREEN PAPERLESS RECORDER 

MODEL : ARC2020  

 

 

ACCSYS ELECTRONICS

 

140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD,  

GERUGAMBAKKAM, CHENNAI - 600122 

Tel: 044 60505599 / 60505511 

E-mail : [email protected] 

 

Содержание ARC2020

Страница 1: ...nics com Page 1 USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL ARC2020 ACCSYS ELECTRONICS 140 6B GOLDEN INDUSTRIAL ESTATE JAWAHARLAL NEHRU ROAD GERUGAMBAKKAM CHENNAI 600122 Tel 044 6050...

Страница 2: ...ng INSTALLATION Installation Location Install the control panel in a location that meets the following criteria 1 Little or no mechanical vibration 2 No corrosive gases 3 Minimal temperature fluctuati...

Страница 3: ...o 50 ohm Open and short circuit detection Type Range C Accuracy C 100 ohm Pt 385 200 to 400 C 0 2 C Recording Recording Rates User programmable from 1 sample per second to 1 sample every 10 hours Data...

Страница 4: ...her Capacity Memory Internal memory 2 4 GB for Higher Data Storage Recording data on storage media Using the Setup menu the user can log the data in internal memory If this memory is full the logged d...

Страница 5: ...11 Compliant Software Web server Based Software Safety and Environmental Operating Range 0 C to 60 C 10 to 90 RH non condensing Dimension Bezel dimension 195 H x 300 W x 5mm above panel Unit dimension...

Страница 6: ...TOUCH SCREEN PAPERLESS RECORDER www accsyselectronics com Page 6...

Страница 7: ...nics com Page 7 OPERATING PARAMETER SETTING Switch ON the device the following display will show the channel readings It will take a few seconds CONFIGURATION SETTING Click CONFIG in the display Enter...

Страница 8: ...DER www accsyselectronics com Page 8 After entering the password the setting screen will be displayed as shown below TIME DATE SETTINGS In Setting SET Real Time Clock Set the real time date details Cl...

Страница 9: ...w accsyselectronics com Page 9 LOG TIME SETTINGS In Setting SET Log Time Set the Log Time Of The Logger Click Ok to save the settings PASSWORD SETTINGS In Setting Click SET Password this feature is us...

Страница 10: ...rm range from the specified values Low 999 High 9999 RANGE Set the range with respect to the Sensor type specification REF PAGE NO 3 OFFSET Set the offset range from 999 to 999 Default set 0 DECIMAL S...

Страница 11: ...front panel of the Logger In Setting Click COPY Memory this feature is used to copy the Logger memory in to the Pen Drive If USB 2 0 drive is not inserted in the drive an error screen PEN DRIVE PROBL...

Страница 12: ...an Ink jet printer through the PRINTER PORT provided in the back panel of Logger In Setting Click PRINT Memory the entire memory will be printed GRAPH After completing all the Settings Click HOME ico...

Страница 13: ...ERMINAL DETAILS ID NUMBER In Setting ID NUMBER SETTING for Multi Logger Software DATA LOGGING OFF Logging Off The Data Logger Click HOME icon in the Setting screen In Setting DATA LOGGING OFF Input Te...

Страница 14: ...n go For step 2 If no check for the power input connections check whether the unit is getting proper supply at proper terminals Connecting the supply to the wrong terminals may damage the unit permane...