11 - 20
11. OPTIONS AND AUXILIARY EQUIPMENT
(c) Cable clamp fitting (AERSBAN - SET (Mitsubishi Electric Corporation))
Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown below.
Install the earth plate near the driver for the encoder cable. Peel part of the cable sheath to expose the
external conductor, and press that part against the earth plate with the cable clamp. If the cable is thin,
clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Cable clamp
(A, B)
Cable
Earth plate
External conductor
40
cutter
cable
Strip the cable sheath of
the clamped area.
Outline drawing
installation hole
Earth plate
Clamp section diagram
(Note)M4 screw
11
3
6
C
A
6
22
17.5
35
35
2- 5 hole
L or less
10
30
B
0.3
7
24
0
.3
0
24
0
0
.2
Note. Screw hole for grounding. Connect it to the earth plate of the control box.
Type
A
B
C
Accessory fittings
Clamp fitting
L
AERSBAN-DSET
100
86
30
clamp A: 2pcs.
A
70
AERSBAN-ESET
70
56
clamp B: 1pc.
B
45