13 - 15
13. POSITIONING MODE
(b) Rough match
The following timing charts show the relationships between the signal and the position command
generated in the driver. This timing can be changed using parameter No. PE12 (rough match output
range). CPO turns ON in the servo-on status. CPO does not turn ON during automatic operation.
3ms or less
ON
OFF
ON
OFF
Forward rotation start
(ST1) or reverse
rotation start (ST2)
Position
command
Rough match (CPO)
0r/min
Forward
rotation
When parameter No. PE12 is set to "0"
ON
OFF
ON
OFF
Rough match output range
0r/min
3ms or less
Forward rotation start
(ST1) or reverse
rotation start (ST2)
Position
command
Rough match (CPO)
Forward
rotation
When parameter No. PE12 is set to more than "0"