4 - 20
4. PARAMETERS
(4) When multiplying A-phase/B-phase output pulses by the value of the electronic gear
Set parameter No. PC13 to " 3 ".
The value resulted from multiplying the number of pulses per servo motor revolution by the value of the
electronic gear becomes the output pulse.
(a) Set the electric gear numerator in the A-phase/B-phase output pulses to parameter No. PA15.
(b) Set the electric gear denominator in the A-phase/B-phase output pulses to parameter No. PA16. Setting
0 to parameter No. PA16 is recognized as 1.
(Example) When using the LE-S1
-□,
LE-S2
-□,
LE-S3
-□,
LE-S
4-□
servo motor series
When parameter No. PA15 is set to "5600" and PA16 to "4096", the A/B-phase pulses
actually outputted are as follows.
A-phase/B-phase output pulses =
Resolution per servo motor revolution ·
parameter No.15
parameter No.16
·
1
4
= 131072 ·
5600
4096
·
1
4
= 44800 [pulse]
Servo motor
Encoder
A-phase/B-phase
output pulses
Feedback pulses
M
ENR2
ENR
Electronic gear
(parameters No. PA15, PA16)
POINT
Resolution per servo motor revolution depends on the servo motor as follows.
LE-S1
-□,
LE-S2
-□,
LE-S3
-□,
LE-S4
-□
servo motor: 131072pulse/rev