4 - 58
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PD25
For manufacturer setting
0000h
PD26
Do not change this value by any means.
0000h
4.4.3 Using forward/reverse rotation stroke end to change the stopping pattern
The stopping pattern is factory-set to make a sudden stop when the forward/reverse rotation stroke end is
made valid. A slow stop can be made by changing parameter No. PD20 setting.
Parameter No. PD20 setting
Stopping method
0
(initial value)
Sudden stop
Position control mode
: The servo motor stops by clearing the droop
pulses.
Internal speed control mode
: The servo motor stops when the deceleration time
constant is zero.
1
Slow stop
Position control mode
: The servo motor decelerates to a stop in
accordance with parameter No. PB03 setting.
Internal speed control mode
: The servo motor decelerates to a stop in
accordance with parameter No. PC02 setting.