8 - 28
8. TROUBLESHOOTING
Alarm No.: A.96
Name: Home position setting error
The servo motor stops.
Warning contents
Incorrectly finished after home position return operation.
Detailed
display
Detailed
Name
Cause
Checking method
Result
Action
96.1
In-position
not reached
1) Droop pulses remaining
are greater than the in-
position range setting.
Check the number of
droop pulses after
home position return.
In-position range or
more
Remove the cause of
droop pulse occurrence.
Alarm No.: A.96
Name: Home position setting error
The servo motor stops.
Description
Incorrectly finished after home position return operation.
Detailed
display
Detailed
Name
Cause
Checking method
Result
Action
96.2
Speed
command
not
converged
1) The speed command does
not become "0" after home
position return.
Check the speed
command value after
home position return.
Speed Command
outputting
Set the speed command
to "0".
Speed Command
not outputting
Check 2).
2) The creep speed is too
fast.
Check the creep
speed.
The creep speed is
too fast.
Reduce the creep speed.
Alarm No.: A.97
Name: Program operation disabled
The servo motor does not stop.
Warning contents
The program operation was performed during program operation disabled status.
Detailed
display
Detailed
Name
Cause
Checking method
Result
Action
97.1
Program
operation
disabled
1) The program was started
without switching OFF/ON
the power of the driver.
Check if the power of
the driver is switched
OFF/ON.
The power of the
driver is not
switched OFF/ON.
Switch OFF/ON the power
of the driver.