5 - 28
5. DISPLAY AND OPERATION SECTIONS
(1) Servo motor speed setting (a)
Enter a new value into the "Motor speed" input field and press the enter key.
(2) Acceleration/deceleration time constant setting (b)
Enter a new value into the "Accel. / decal. time constant" input field and press the enter key.
(3) Moving distance setting (c)
Enter a new value into the "Move distance" input field and press the enter key.
(4) Servo motor start (d)
Click the "Forward CCW" button to rotate the servo motor in the forward rotation direction.
Click the "Reverse CW" button to rotate the servo motor in the reverse rotation direction.
(5) Temporary stop of servo motor (e)
Click the "Pause" button to stop the servo motor temporarily.
Click the "Forward CCW" button or "Reverse CW" button during the temporary stop to restart the rotations
for the remaining move distance.
(6) Servo motor stop (f, g))
Click the "Stop" button or "Forced stop" button to stop the servo motor rotation.
(7) Servo motor Forced stop (g)
Click the "Forced stop" button to stop the servo motor rotation immediately. When the "Forced stop" button
is enabled, the "Forward CCW" and "Reverse CW" buttons cannot be used. Click the "Cancel stop" button
to make the "Forward CCW" and "Reverse CW" buttons enabled.
a
b
c
d
e
f
g
h
i
j