13 - 11
13. POSITIONING MODE
Device
Symbol
Connector
pin No.
Functions/Applications
I/O
division
Positioning
mode
CP
CL
During tough
drive
MTTR
If the instantaneous power failure tough drive function selection is
enabled, MTTR turns on when the instantaneous tough drive
activates.
If parameter No.PD20 is set to " 1 ", MTTR also turns on when
the overload tough drive activates.
DO-1
Position range
POT
POT turns ON when the actual current position falls within the range
set in the parameter.
It is OFF when a home position return is not yet completed or while
the base circuit is shut off.
DO-1
Point table No.
output 1
PT0
As soon as travel completion (MEND) turns ON, the point table No. is
output in 3-bit code.
DO-1
(Note) Device
Description
PT2
PT1 PT0
Point table No.
output 2
PT1
0
0
1
Point table No. 1
DO-1
0
1
0
Point table No. 2
0
1
1
Point table No. 3
1
0
0
Point table No. 4
Point table No.
output 3
PT2
1
0
1
Point table No. 5
DO-1
1
1
0
Point table No. 6
1
1
1
Point table No. 7
Program
output 1
OUT1
OUT1 turns on when the OUTON (1) command in the program is
given. OUT1 turns off when the OUTOF command is given.
By setting parameter No. PE14, the time to turn it off can be set.
DO-1
SYNC
synchronous
output
SOUT
Waiting for input of program SYNC (1).
DO-1