6 - 7
6. GENERAL GAIN ADJUSTMENT
(5) At alarm occurrence
During the one-touch tuning
Alarm display
If some alarm occurs during the one-touch tuning, the one-touch tuning is canceled, and
the alarm display is called.
(6) At warning occurrence
During the one-touch tuning
Warning
reset
Alarm display (warning)
Completion display
One-touch tuning complete
(a) If some warning occurs during the one-touch tuning, the alarm display is called, and
the warning is displayed. However, one-touch tuning continues to be performed.
(b) When the warning is reset, the alarm display is shifted to the one-touch tuning.
Waning
occurrence