4 - 4
4. PARAMETERS
4.1.2 Parameter write inhibit
Parameter
Initial
value
Setting
range
Unit
Control mode
No.
Symbol
Name
Position
Internal
speed
Internal
torque
PA19
*BLK
Parameter write inhibit
00Eh
Refer to
the text.
POINT
This parameter is made valid when power is switched off, then on after setting.
In the factory setting, this driver allows to change all the setting parameters. With the setting of parameter No.
PA19, writing can be disabled to prevent accidental changes.
The following table indicates the parameters which are enabled for reference and writing by the setting of
parameter No. PA19. Operation can be performed for the parameters marked .
Parameter No. PA19
setting
Setting
operation
Basic setting
parameters
No. PA
Gain/Filter
parameters
No. PB
Extension setting
parameters
No. PC
I/O setting
parameters
No. PD
Positioning
setting
parameters
No. PE
000h
Reference
Writing
00Ah
Reference
Parameter No.
PA19 only
Writing
Parameter No.
PA19 only
00Bh
Reference
Writing
00Ch
Reference
Writing
00Eh
(initial value)
Reference
Writing
10Bh
Reference
Writing
Parameter No.
PA19 only
10Ch
Reference
Writing
Parameter No.
PA19 only
10Eh
Reference
Writing
Parameter No.
PA19 only