4 - 36
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PC05 SC0 Internal speed command 0
Used to set speed 0 of internal speed commands.
0
0 to
instan-
taneous
permi-
ssible
speed
r/min
Internal speed limit 0
Used to set speed 0 of internal speed limits.
PC06 SC1 Internal speed command 1
Used to set speed 1 of internal speed commands.
100
0 to
instan-
taneous
permi-
ssible
speed
r/min
Internal speed limit 1
Used to set speed 1 of internal speed limits.
PC07 SC2 Internal speed command 2
Used to set speed 2 of internal speed commands.
500
0 to
instan-
taneous
permi-
ssible
speed
r/min
Internal speed limit 2
Used to set speed 2 of internal speed limits.
PC08 SC3 Internal speed command 3
Used to set speed 3 of internal speed commands.
1000
0 to
instan-
taneous
permi-
ssible
speed
r/min
Internal speed limit 3
Used to set speed 3 of internal speed limits.
PC09 MBR Electromagnetic brake sequence output
Used to set the delay time (Tb) from the electromagnetic brake
interlock (MBR) turns off to the base drive circuit is shut-off.
100
0
to
1000
ms
PC10 ZSP Zero speed
Used to set the output range of the zero speed detection (ZSP).
Zero speed detection (ZSP) has hysteresis width of 20r/min (refer to
section 3.5 (1) (b))
50
0
to
10000
r/min
PC11 *BPS Alarm history clear
Used to clear the alarm history.
Alarm history clear
0: Invalid
1: Valid
When alarm hist ory clear is made valid, the alarm
history and the number of tough drive are cleared at
next power-on.
After the alarm history and the number of tough drive
are cleared, the setting is automatically made invalid
(reset to 0).
0
Presence or absence of drive recorder selection
0: Valid (drive recorder execution)
1: Invalid (drive recorder stop)
MR Configurator is necessary referring to the drive
recorder. (Refer to Section 4.3.4.)
000h Refer to
the name
and
function
field.
PC12
TC
Internal torque command
Set the internal torque command during the internal torque control.
0.0
0.0
to
100.0
%
MR Configurator 2
TM
is necessary referring to the drive
recorder.(Refer to Section 4.3.4.)