5 - 19
5. DISPLAY AND OPERATION SECTIONS
5.7.2 Operation example
POINT
When the set value of a specified parameter is changed and entered, the entered
set value is displayed. The set value can be cancelled by pressing the "MODE"
button for 2[s] or longer immediately after entering the value. Then, the previous
set value is displayed.
(1) Parameter of 3 or less digits
The following example shows the operation procedure performed after power-on to change the control
mode (parameter No. PA01) to the internal speed control mode. Press "MODE" to switch to the basic
setting parameter screen.
Press UP or DOWN to change the number.
The set value of the specified parameter number flickers.
Press SET twice.
Press UP twice.
During flickering, the set value can be changed.
Use UP or DOWN.
( 2: Internal speed control mode)
Press SET to enter.
The parameter number is displayed.
To shift to the next parameter, press the "UP" or the "DOWN" button.
When changing parameter No. PA01 setting, change its set value, then switch power off once and switch it