4 - 30
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PB34 VRF2B Gain changing vibration suppression control resonance frequency
setting [Applied]
Set the resonance frequency for vibration suppression control when
the gain changing is valid. This parameter is made valid when
parameter No. PB02 is set to " 2" and parameter No. PB26 is set
to " 1".
When using the vibration suppression control gain changing, always
execute the changing after the servo motor has stopped.
100.0
0.1
to
100.0
Hz
PB35
For manufacturer setting
0
PB36
Do not change this value by any means.
0
PB37
100
PB38 NH3 Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
Set parameter No. PB39 (notch shape selection 3) to " 1" to
make this parameter valid.
4500
30
to
4500
Hz
PB39 NHQ3 Notch shape selection 3
Used to select the machine resonance suppression filter 3.
Notch depth selection
Depth
Gain
0
Deep
1
2
3
Shallow
to
Notch width selection
Width
0
2
Standard
1
3
2
4
3
5
Wide
to
Machine resonance suppression filter 3 selection
0: Invalid
1: Valid
Setting
Setting
40dB
14dB
8dB
4dB
000h
Refer to
name and
function
column.
PB40
For manufacturer setting
111h
PB41
Do not change this value by any means.
20
PB42
000h
PB43
000h
PB44
000h
PB45
000h
PB46
000h
PB47
000h
PB48
000h
PB49
000h
PB50
000h