4 - 55
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PD15 *DO1 Output signal device selection 1 (CN1-9)
Any output signal can be assigned to the CN1-9pin. ALM is assigned
as the initial value.
Note that the device that can be assigned varies depending on the
control mode.
Select the output device of the CN1-9 pin.
0 0
The devices that can be assigned in each control mode are indicated
by abbreviation in the following table. If any other device is set, it is
invalid.
0003h Refer to
the
name
and
function
field.
○
○
○
Setting
Control modes (Note 1)
P
S
T
CP/CL
00
Always OFF Always OFF Always OFF Always OFF
01
For manufacturer setting (Note 2)
02
RD
RD
RD
RD
03
ALM
ALM
ALM
ALM
04
INP
SA
Always OFF
INP
05
MBR
MBR
MBR
MBR
06
For manufacturer setting (Note 2)
07
TLC
TLC
VLC
TLC
08
WNG
WNG
WNG
WNG
09
For manufacturer setting (Note 2)
0A
Always OFF
SA
Always OFF Always OFF
0B
Always OFF Always OFF
VLC
Always OFF
0C
ZSP
ZSP
ZSP
ZSP
0D
MTTR
MTTR
MTTR
MTTR
0E
For manufacturer setting (Note 2)
0F
CDPS
Always OFF Always OFF
CDPS
10
~
1F
For manufacturer setting (Note 2)
20
Always OFF Always OFF Always OFF CP0
(Note3)
21
Always OFF Always OFF Always OFF
ZP
22
Always OFF Always OFF Always OFF
POT
23
Always OFF Always OFF Always OFF
PUS
24
Always OFF Always OFF Always OFF
MEND
25
Always OFF Always OFF Always OFF PT0
(Note3)
26
Always OFF Always OFF Always OFF PT1
(Note3)
27
Always OFF Always OFF Always OFF PT2
(Note3)
28
Always OFF Always OFF Always OFF
OUT1(Note4)
29
Always OFF Always OFF Always OFF
SOUT(Note4)
2A
~
3F
For manufacturer setting (Note 2)
Note 1. P: Position control mode
S: Internal speed control mode
T: Internal torque control mode
CP:Positioning mode (Point table method)
CL:Positioning mode (Program method)
2. For manufacturer setting. Never set this value.
3. For the program method, it is always OFF.
4