5 - 9
5. DISPLAY AND OPERATION SECTIONS
Name
Symbol
Unit
Description
Display
range
Current position in
10
STM
m unit (Note 1)
PSL
10
STM
m The current position is displayed based on the machine home position
being regarded as "0".
Negative values are indicated by the lit decimal points in the upper two
digits.
-999 to 999
Current position in 1000
10
STM
m unit (Note 1)
PSH
1000
10
STM
m
-999 to 999
Command position in
10
STM
m unit (Note 1)
CPL
10
STM
m
The internal command position is displayed.
Negative values are indicated by the lit decimal points in the upper two
digits.
-999 to 999
Command position in
1000
10
STM
m unit
(Note 1)
CPH
1000
10
STM
m
-999 to 999
Command remaining
distance in 10
STM
m unit
(Note 1)
rnL
10
STM
m The remaining distance to the command position specified by the
selected point table is displayed.
The value in excess of 999999 can be counted. However, the counter
shows only the lower or higher three digits since the driver display is
three digits.
0 to 999
Command remaining
distance in 1000
10
STM
m unit (Note 1)
rnH
1000
10
STM
m
0 to 999
Point table No. (Note 1)
Pno
The point table No./Program No. which is being performed is displayed.
During automatic operation or temporary stop
: Displays the No. being performed.
During stop : Displays the selected No.
During manual operation : Displays 0.
0 to 7
Program No. (Note 1)
0 to 8
Step No. (Note 2)
Sno
The step No. of the program which is being performed is displayed.
0: During stop
1 to 120: Step No. of the program which is being performed.
0 to 120
Note 1. It can be displayed in the positioning mode (point table method and program method).
2. It can be displayed in the positioning mode (program method).