4 - 6
4. PARAMETERS
Note 3. To set the maximum value for the each method, it is necessary to change the setting.
Please refer
「
13. POSITIONING MODE
」
.
Note 4. The setup software (MR Configurator2
TM
) is necessary to control by the program method.
Please prepare separately.
・
Setup software Japanese version (MR Configurator2
TM
) / LEC-MRC2E
・
USB cable for setup software (3m) / LEC-MR-J3USB
4.1.4 Selection of regenerative option
Parameter
Initial
value
Setting
range
Unit
Control mode
No.
Symbol
Name
Position
Internal
speed
Internal
torque
PA02
*REG Regenerative option
000h
Refer to
the text.
POINT
This parameter is made valid when power is switched off, then on after setting.
Incorrect setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the driver, parameter error
(37.2) occurs.
Set this parameter when using the regenerative option.
Selection of regenerative option
00: Regenerative option is not used
For servo amplifier of 100W, regenerative resistor is not used.
For servo amplifier of 200 to 400W, built-in regenerative resistor is used.
02: MR-RB032
03: MR-RB12
0
Parameter No. PA02
Selection of regenerative option
00:Regenerative option is not used
・
For driver of 100W, regenerative resistor is not used.
・
For driver of 200W to 400W, regenerative resistor is not used.
02:LEC-MR-RB-032
03:LEC-MR-RB-12