13 - 94
13. POSITIONING MODE
13.10 Single-step feed usage in the test operation mode
This section provides the usage of single-step feed using set up software(MR Configurator2
TM
).
POINT
The single-step feed is supported by driver with software version B0 or later,
and set up software(MR Configurator2
TM
) with software Ver.1.52E or later.
The servo motor will not operate if the forced stop (EM1), forward rotation
stroke end (LSP) and reverse rotation stroke end (LSN) are off. Make
automatic ON setting to turn on these devices or turn on between DOCOM.
(Refer to section 4.4.2.)
Operation is performed in accordance with the preset point table No./program No.
Click "Single-step Feed" on the menu.
Clicking displays the confirmation window for switching to the test operation mode.
Click the "OK" button to display the setting screen of the single-step feed.
<In point table operation> <In program operation>
1) Point table No. setting
Enter the point table No. into the "Point table No." input field and press the enter key.
2) Program No. setting
Enter the program No. into the "Program No." input field and press the enter key.
1)
2)
3)
3)
4)
4)
5)
6)
5)
6)
7)
7)