4 - 22
4. PARAMETERS
No. Symbol
Name
Initial value Unit
Control mode
Position
Internal
speed
Internal
torque
PB34 VRF2B
Gain changing vibration suppression control resonance frequency
setting
[Applied]
100.0
Hz
PB35
For manufacturer setting
0
PB36
0
PB37
100
PB38 NH3 Machine resonance suppression filter 3
4500
Hz
PB39 NHQ3 Notch shape selection 3
000h
PB40
For manufacturer setting
111h
PB41
20
PB42
000h
PB43
000h
PB44
000h
PB45
000h
PB46
000h
PB47
000h
PB48
000h
PB49
000h
PB50
000h