5 - 12
5. DISPLAY AND OPERATION SECTIONS
5.5 Alarm mode
The current alarm, the past alarm history, the number of tough drive, the number of drive recorder record times,
and the parameter error No. are displayed. The lower 2 digits on the display indicate the alarm number that has
occurred or the parameter number in error.
Name
Display
Description
Current alarm
Indicates no occurrence of an alarm.
2[s] intervals
Indicates the occurrence of alarm 33 (overvoltage: detail 1).
Flickers at occurrence of the alarm.
Alarm No. and detail No. are displayed alternately in 2[s] intervals.
Alarm history
SET
Indicates the last alarm.
If the last alarm is 50 (overload: detail 1), alarm No. 50 (with detail No.) is
displayed while holding down the "SET" button.
Indicates in hexadecimal for the second to the sixteenth alarm in the past
as shown on the left. The alarm No. (with detail No.) is displayed while
holding down the "SET" button.
The number of tough drive
Indicates the number of tough drive from 0 to 99. The number of tough
drive can be cleared by setting parameter No. PC11 (alarm history clear)
to " 1".
The number of drive
recorder record times
SET
Indicates the number of drive recorder record times. The number of times
is displayed while holding down the "SET" button.