PA13 Selection of command input pulse form (refer to section 4.1.11)
Select the input form of the pulse train input signal. Command pulses may be input in any of three different
forms, for which positive or negative logic can be chosen.
Arrow
or
in the table indicates the timing of importing a pulse train. A- and B-phase pulse trains
are imported after being multiplied by 4.
Forward rotation
pulse train
Reverse rotation
pulse train
Selection of command input pulse form
Parameter No. PA13
Setting
00
01
Pulse train input filter selection
Pulse train form
Forward rotation command Reverse rotation command
Signed pulse
train
A-phase pulse
train
B-phase pulse
train
Forward rotation
pulse train
Reverse rotation
pulse train
Signed pulse
train
A-phase pulse
train
B-phase pulse
train
02
10
12
11
Posi
ti
v
e
l
o
gi
c
NP
PP
PP
L
H
NP
PP
NP
NP
PP
L
H
PP
NP
PP
NP
Setting
Command pulse frequency
0
1Mpps or less
1
500kpps or less
2
200kpps or less
Neg
at
iv
e
l
o
gi
c
POINT
The noise immunity can be enhanced by setting parameter No. PA13 to "1 "
when the frequency of the command input pulse is 500kpps or less and "2 "
when 200kpps or less.