13 - 8
13. POSITIONING MODE
Device
Symbol
Connector
pin No.
Functions/Applications
I/O
division
Positioning
mode
CP
CL
Forward
rotation start
ST1
CN1-6
1. For automatic operation mode
Turning ST1 ON executes the program operation selected in DI0
to DI2.
2. For JOG operation in manual operation mode
Keeping ST1 ON performs rotation in the forward rotation
direction. Forward rotation indicates the address increasing
direction.
DI-1
Reverse
rotation start
ST2
CN1-7
Keeping ST2 ON in JOG operation in manual operation mode
performs rotation in the reverse rotation direction. Reverse rotation
indicates the address decreasing direction.
ST2 is invalid in other operation modes.
DI-1
Gain changing
CDP
The values of the load to motor inertia moment ratio and the gains
are changed to the value set in parameter No. PB29 to PB34 by
turning CDP on.
DI-1
Point table
No.
/Program No.
selection 1
DI0
CN1-5
<In point table method>
The point table No. and the home position return mode are selected
by DI0 to DI2.
<In program method>
The program No. is selected by DI0 to DI2.
DI-1
(Note) Device
Selection description
Point table No.
/Program No.
selection 2
DI1
CN1-23
DI2 DI1 DI0
Point table method
Program method
DI-1
0
0
0
Home position return mode
Program No. 1
0
0
1
Point table No. 1
Program No. 2
0
1
0
Point table No. 2
Program No. 3
0
1
1
Point table No. 3
Program No. 4
1
0
0
Point table No. 4
Program No. 5
Point table No.
/Program No.
selection 3
DI2
1
0
1
Point table No. 5
Program No. 6
DI-1
1
1
0
Point table No. 6
Program No. 7
1
1
1
Point table No. 7
Program No. 8
Note. 0: off
1: on
Program
input 1
PI1
Turn PI1 on to resume the step stopped by the SYNC (1) command
in the program.
DI-1