Installation Instructions

 

ELEKTROMAT 
ST 60.15-50,00

 

Model: 10003340 00005

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 25.11.2021

 

 

 

Summary of Contents for 10003340 00005

Page 1: ...f Installation Instructions ELEKTROMAT ST 60 15 50 00 Model 10003340 00005 en Status 25 11 2021 ...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de ...

Page 3: ...n 13 7 Completing commissioning inspection 14 8 Disposal 16 9 Declaration of incorporation Declaration of conformity 17 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required action Schematic representations are based on product examples Deviations from delivered products are possible ...

Page 4: ... experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The safe operation of the product can only be ensured if it is used as specified Follow the installation instructions Observe all specifications especially warnings when installing the product in the ove...

Page 5: ... Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if the drive unit is subjected to impermissible forces Inadmissible forces examples collision with a forklift dropping the drive unit tearing or pulling on the motor lead to damage to the drive unit The...

Page 6: ...factor cos φ 0 59 Safety circuit 24 V Degree of protection IP 54 Temperature range 20 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 26 26 min 1 Cycles per hour 9 3 0 1 h 1 Max load 60000 N Braking torque 130 Nm Braking voltage 103 V DC Rectifier type B1 230 103 1 Specification in according to EN 60335 2 103 2 When using a temperat...

Page 7: ...7 If the magnetic brake will be continuously supplied the drive can be fitted into areas down to a 20 C ambient temperature ...

Page 8: ...even for maximum holding or locking torque observe technical data Connection elements Use self locking connection elements with a minimum strength of 800 N mm2 8 8 Use a screw that precisely fits the hole Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC04301_Z002 ...

Page 9: ...9 Mounting 4 boreholes are provided for mounting BAGAD04301_Z002 ...

Page 10: ...evice with sufficient load carrying capacity for installation tasks Adequate space around the adjusting screw must be ensured for the safe activation of the slipping clutch The output shaft must not be shortened BAGAE03301_Z001 Tighten all connection elements M16 with a torque of 175 Nm Install all further connection elements according to the specifications of the door manufacturer BAGAE004302_Z00...

Page 11: ...g of the slipping clutch The slipping clutch acts as an overload protection The factory setting for the tightening torque is 24Nm ST 60 or 30Nm ST 80 Rotation to the right will increase the transmittable torque Rotation to the left will decouple the drive unit from the door BAGAE4303_Z002 SW 17 ...

Page 12: ...ergised Observe the applicable regulations and standards Make the electrical connection according to standard Use suitable tools Performing electrical installation Remove the cover Connect the motor cables and brake cables BAHAA19_Z001 BAHAB08_Z001 Completing the electrical installation Mount the cable entries and or cable glands ...

Page 13: ...13 5 Motor connection G1 Half wave rectifier M1 Motor Y1 Magnetic brake 6 Limit switch connection F10 Thermal contact ...

Page 14: ...cted Protect the output shaft permanently against corrosion Mounting Check that all connection elements consoles torque mounts screws locking rings etc are secure and in proper condition Electrical wiring Check the connection cables and cabling for damage or crushing Check that the screw connections and plug connections are fitted properly with a good electric contact ...

Page 15: ...st be observed In an environment that can affect the coefficient of friction of the brake pad atmosphere with oil solvents detergents etc class of protection IP65i must be adopted Note Engage a qualified engineer to check the drive unit annually Apply shorter inspection intervals for doors that are operated frequently Observe the applicable regulations and standards ...

Page 16: ...ose of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough postage to the package and mark it as old devices Notice Environmental damage The gearbox contains oil Ensure proper disposal according to local legal regulations ...

Page 17: ... complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 1 5 13...