SKYROS Corporation VideoNet 8.4 User guide
214
Attention!
It is important to understand that by adding
Event from detector
by camera
event into the schedule, you necessitate the system only to
establish the fact of the event occurrence.
?
When configuring
Event from detector by camera
event, it is necessary to remember
the following. If this event is configured to detect motion or to control left objects in a
specified
zone
, then additional presets
zones
configuring (for example, such as changing
of a zone
number, merging several zones into one or deleting zones, refer to
3.2
chapter) can lead to
zone numbers
changing or setting the
numbers
free. In this
case:
• if the event is configured to a zone number, which became unusable, the event will
have the exclamation mark
in the task tree, and the
zone
field will have the
following text
“error number”
.
• if the event is configured to a zone number, which was reassigned to another zone,
the event will have this new zone number and all specified parameters unchanged.
Select this option, if you want the system to log all detected events by
this camera into the
Event Log
.
Add message
to Event Log
If sabotage detector is selected as a detector, you can configure event properties
on the
Alarm reset
tab.
On the
Alarm reset
tab you can configure output of an
alarm message
about
sabotage to the status panel. Also you can configure necessity to register alarm
reset confirmation by system operator in the Event Log. Operator should confirm
message receiving by pressing corresponding button on the status panel. Having
selected this check-box, you can control system operator’s work, by checking
number of missed or received by operator alarm messages in the Event Log
(refer to
4.1.6
section).
Option
Alarm duration
Unlimited duration
Output alarm
message to the
screen
Log alarm reset
confirmation
Description
Specify time interval, after which alarm must be resetted.
Select this option, if you don’t want to limit alarm duration by any time
interval.
Select this option, if you want the system to output
alarm message
to the screen. With this option selected an alarm message will appear
on the status panel.
Select this option, if you want all the facts of message receiving
confirmation by an operator to be added to the Event Log. This
enables you to control operator’s attentiveness and to reconstruct
an accident scene.