06.03
7.3 SIMATIC S7 project
7-239
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
If you double-click on a DP slave 611U in the station window, the dialog box:
“DP slave properties” opens.
We recommend activating the equidistant DP cycle for all DP slaves 611U by
activating the equidistant DP cycle within the selected DP slave 611U and finally
adjusting.
During the adjustment, all:
S
DP slave properties
displayed in the tab: Clock Synchronization
are transferred to all DP slaves of the same type in the configuration, here DP
slave 611U.
Dialog: DP Slave Properties
Tab: Clock synchronization
Optional field: “Synchronize drive to equidistant DP cycle”
Button:
“Adjust”
Factor
General
Equidistant bus cycle activated
Network settings in msec:
Synchronize drive to equidistant DP cycle
Clock synchronization
Configuration
Cyclic portion of equidistant master
Setpoint acceptance [msec]:
Actual-value sensing [msec]:
Basic time [msec]
Master application cycle
[msec]:
4.000
Equidistant DP cycle:
0.367
DP cycle [msec]:
1.000
1.000
1.000
0.125
0.125
0.125
4
1
8
1
0.500
0.125
Help
Cancel
OK
Adjust
DP slave properties
Factor
Factor
Factor
Basic time [msec]
Basic time [msec]
Basic time [msec]
=
=
=
=
x
x
x
x
Fig. 7-9
Enabled equidistant DP cycle
Notice
If there are different types of equidistant DP slaves in a S7 project, e.g. different
SIMODRIVE drives, ADI4, etc., the following steps:
1. Synchronize drive to equidistant DP cycle
2. Adjust
must be performed for each type of DP slave first before you can go on to set
the other parameters.
Activation of the
equidistant
DP cycle
Dialog:
Start
7 PROFIBUS DP Communication
Содержание SINUMERIK 840Di
Страница 1: ...Manual 06 2003 Edition SINUMERIK 840Di ...
Страница 2: ......
Страница 522: ...06 03 A 522 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition A Abbreviations Notes ...
Страница 548: ...06 03 Index 548 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition Index ...
Страница 550: ......