7.3 SIMATIC S7 project
7-216
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
7.3.4
SIMATIC S7 I/O devices
The SIMATIC I/O devices of the series ET200, e.g. ET200M, are integrated into
the S7 project as usual and configured.
Note
To simplify parameterization of the equidistant communication on the PROFI-
BUS DP, you must first insert all the SIMATIC S7 I/Os you require into the con-
figuration before parameterization of the DP drives (e.g. DP slave 611U or
ADI4).
Note
To check whether a module selected from the hardware catalog complies with
the module in the automation system, the following procedure is recom-
mended:
1. Put down the MLFB numbers of all modules used in the automation system.
2. Select the appropriate module from the hardware catalog and compare the
order number (MLFB) with the MLFB number of the module displayed in the
hardware catalog. Both MLFB numbers must be the same.