06.03
9.1 SIMODRIVE 611 universal/E, POSMO CD/CA and SI
9-269
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
9.1.6
Setting the routing information
Setting the routing information:
–
MPI address of the PLC
–
PROFIBUS subnetwork ID.
The easiest method to do so is the expert mode after resetting the routing infor-
mation.
Notice
To use the PLC as a router between MPI and PROFIBUS DP, the MPI network-
ing of the PLC must be parameterized in the S7 project.For network rules, see
Subsection 7.3.2, page 7-212.
Button: “Reset routing information...”
Radio button: Expert mode
MPI No: 2 (see Note)
PROFIBUS: <Subnetwork ID> (see below)
OK or Go online.
Notice
With SINUMERIK 840Di, the routing of the MPI interface to the PROFIBUS DP
is provided the PLC. Therefore, the MPI address of the PLC must be specified
as the “MPI No”.
With SINUMERIK 840Di, the PLC always has the MPI address 2.
Enter the 8-digit PROFIBUS S7 subnetwork ID of DP master (S7 project) in the
12-digit input screen form of the SimoCom U dialog as follows:
Example:
S7 project: 8-digit S7 subnetwork ID:
0010
0005
–
SimoCom U: 12-digit S7 subnetwork ID:
10
00
05
00
00
00
If you do not have the PROFIBUS S7 subnetwork ID, you can call it using the
SIMATIC Manager STEP7
To do so, proceed as follows:
S
Open the appropriate S7 project in the SIMATIC Manager S7.
S
Select the appropriate station (in the example project: SIMATIC 300)
SimoCom U dialog:
End
Entering the
PROFIBUS S7
subnetwork ID
Determining
PROFIBUS S7
subnetwork ID
9 Drive Start-Up (Preconditions)
Содержание SINUMERIK 840Di