06.03
10.6 Digital and analog I/O devices
10-386
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
ET200
2 output bytes
ADI4
2 output bytes.
Note
Although only four output bytes are used, five must be declared. The 1st output
byte is always assigned to the MCI board extension module even if it is not
installed:
–
MD10360: FASTIO_DIG_NUM_OUTPUTS = 5
The following input bytes are used by the NC:
ET200
Both input bytes of the input module (slot 6)
–
MD10366: HW_ASSIGN_DIG_FASTIN[0] = H05000080 (128
D
)
–
MD10366: HW_ASSIGN_DIG_FASTIN[1] = H05000081 (129
D
)
The 4th of the 4 input bytes of the signal module (slot 7)
–
MD10366: HW_ASSIGN_DIG_FASTIN[2] = H05000085 (133
D
)
ADI4
The high byte of the input word (slot 21)
–
MD10366: HW_ASSIGN_DIG_FASTIN[3] = H0500014B (331
D
)
The following output bytes are used by the NC:
ET200
The 1st output byte of the output modules (slots 4 and 5)
–
MD10368: HW_ASSIGN_DIG_FASTOUT[0] = H05000080 (128
D
)
–
MD10368: HW_ASSIGN_DIG_FASTOUT[1] = H05000082 (130
D
)
ADI4
Both output bytes of the output word (slot 22)
–
MD10366: HW_ASSIGN_DIG_FASTOUT[2] = H0500014A (330
D
)
–
MD10366: HW_ASSIGN_DIG_FASTOUT[3] = H0500014B (331
D
)
Number of
output bytes
Hardware
assignment:
input bytes
Hardware
assignment:
output bytes
10 NC Start-Up with HMI Advanced
Содержание SINUMERIK 840Di
Страница 1: ...Manual 06 2003 Edition SINUMERIK 840Di ...
Страница 2: ......
Страница 522: ...06 03 A 522 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition A Abbreviations Notes ...
Страница 548: ...06 03 Index 548 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition Index ...
Страница 550: ......