06.03
10.3 System data
10-286
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
The control has been started up with default values. Axis A1 is declared as a
linear axis.
S
MD 30300: IS_ROT_AX[A1] = 0 (no rotary axis)
S
MD32000: MAX_AX_VELO [A1] = 1000 [mm/min] (max. axis velocity).
Axis A1 is now declared as a rotary axis containing the following machine data:
S
MD 30300: IS_ROT_AX = 1 (rotary axis)
S
MD32000: MAX_AX_VELO [A1] = 1000 [mm/min] (max. axis velocity).
With the next NCK reset, the control system recognizes that axis A1 is defined
as a rotary axis and rescales MD32000: MAX_AX_VELO to [rev./min] with refer-
ence to a rotary axis.
S
MD 30300: IS_ROT_AX = 1 (rotary axis)
S
MD32000: MAX_AX_VELO [A1]= 2.778 [rev./min].
Note
If a scaling machine data item is altered, then the control outputs alarm
“4070 Scaling data changed”.
The following procedure is recommended when modifying scaling machine data
manually:
1. Set all scaling machine data
2. Carry out NCK reset
3. Set all dependent machine data after the NC has powered up.
10.3.4
Loading default machine data
The default machine data can be loaded in different ways.
Via the SINUMERIK 840Di standard user interface 840Di start-up:
Menu command Window > Diagnosis > NC/PLC
S
Button: “Delete NCK Data”
S
Button: “NCK RESET”
Notice
With deleting the NCK data, all user data are lost.
To avoid data loss, a series machine start-up file should be created before the
NCK data are deleted. How to create a series machine start-up file is described
in Section 14.2, page 14-451.
Modifying
manually
840Di start-up
10 NC Start-Up with HMI Advanced
Содержание SINUMERIK 840Di
Страница 1: ...Manual 06 2003 Edition SINUMERIK 840Di ...
Страница 2: ......
Страница 522: ...06 03 A 522 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition A Abbreviations Notes ...
Страница 548: ...06 03 Index 548 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition Index ...
Страница 550: ......