06.03
10.6 Digital and analog I/O devices
10-384
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
R
Computational time of position controller and/or signal module
Dx
User data exchange between DP master and DP slaves
MSG
Acyclic services (e.g. DP/V1, token transfer)
RES
Reserve: “active break” until the equidistant cycle has elapsed
1
Set the system variables, e.g. $A_OUT[8] in the parts program or
synchronized action
2
Transmit the output signal to the signal module on
PROFIBUS DP
3
Connect the signal to the output of the module.
10.6.6
Configuration example
In the following configuration example the following input/outputs are available
to the NC:
ET200
–
24 digital inputs
–
16 digital outputs
ADI4
–
8 digital inputs
–
16 digital outputs
Note
The I/O addresses of the modules are assigned automatically by “HW Con-
fig”. (Manual adjustment is possible.)
Each I/O address refers to an input/output byte.
PROFIBUS(2): DP master system (2)
840Di (configuration) –– 840Di_ET200_ADI4
(0) 840Di
(0) UR
X2
PLC315-2DP M/S 2AF03
DP Master
2
4
CP 342–5
(5) IM 153
(6) ADI4
Fig. 10-35 Example configuration: SINUMERIK 840Di with ET200 and ADI4
10 NC Start-Up with HMI Advanced