06.03
16.3 Travel to fixed stop with high-resolution torque reduction (SW 2.2 and higher)
16-515
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
16.3.6
Data description (MD)
13070
DRIVE_FUNCTION_MASK
MD number
Bit-coded screen for selecting the functional scope expected by the NCK with PROFIBUS
drives
Default settings: 0
min. input limit: 0
max. input limit: FFFF FFFF
Changes effective after power ON
Protection level: 2/7
Unit: –
Data type: DWORD
valid from SW: 2.1
Meaning:
Meaning of set bits:
Bit 0: Deactivation of the 611U-specific drive alarm mapping
Bit 1: Deactivation of the 611U-specific drive type detection
Bit 2: Deactivation of the 611U-specific parameter accesses encoder drivers
Bit 3: Deactivation of the 611U-specific parameter accesses output drivers
Bit 4: Activation third-party drive: DSC bits (CTW1.12/STW1.12)
Bit 5: Deactivation of the 611U-specific drive parks (CTW2.7/STW2.7)
Bit 6: Deactivation of the 611U-specific travel to fixed stop (CTW2.8/STW2.8)
Bit 7: Deactivation of the 611U-specific motor changeover internal (STW2.9–11)
Bit 8: Deactivation of the 611U-specific ramp block (CTW1.13)
Bit 9: Deactivation of the 611U-specific function generator functions (CTW1.8/STW1.13)
Bit 14: Selection of non-cyclic DP communication: 0=DPT; 1=DPV1
Bit 15: Deactivation of consistency check for PROFIBUS message frame configuration
CTW:
Control word (PDA word in the PROFIDrive message frame to DP slave)
STW:
Status word (PDA word in the PROFIDrive message frame from DP slave)
PDA:
Process data
MD irrelevant with ......
–––
37620
PROFIBUS_TORQUE_RED_RESOL
MD number
torque reduction resolution on PROFIBUS (LSB weighting)
Default settings: 1
min. input limit: 0.01
max. input limit: 10
Changes effective after NEWCONF
Protection level: 2 / 7
Unit: %
Data type: DOUBLE
valid from SW: 2.2
Meaning:
For the drives connected via PROFIBUS, the MD defines the resolution of the torque re-
duction transferred in the cyclic SIMODRIVE standard message frames 102 to 107 (control
word: TorRed). The torque reduction is e.g. required as part of the function “Travel to fixed
stop” (FXST).
At automatic adjustment, the machine data must be set so that it is consistent with the
meaning of drive parameter P0881: “Torque reduction evaluation”; or with manual adjust-
ment with the drive-end interpretation of the control word: TorRed.
The default value of 1% corresponds to the resolution that was valid prior to SW 2.2.
16.3.7
Alarms
Detailed information on the individual alarms can be found in:
References:
/DA/
Diagnostics Guide
For systems with HMI Advanced you can refer to the online help.
J
General machine
data
Axis-specific
machine data
16 840Di Specific Data and Functions
Содержание SINUMERIK 840Di
Страница 1: ...Manual 06 2003 Edition SINUMERIK 840Di ...
Страница 2: ......
Страница 522: ...06 03 A 522 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition A Abbreviations Notes ...
Страница 548: ...06 03 Index 548 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition Index ...
Страница 550: ......