06.03
15.3 Data backup
15-484
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
7. If you do not wish to save the local backup copies of saved partitions (see
next section) available on the hard disk of the PCU, then choose:
–
Backup WITHOUT Local Images using the key “1”.
Otherwise, choose:
–
Backup WITH Local Images using the key “2”.
A message window appears:
–
You will be prompted to check whether the connection between the PCU
and the external computer is established.
–
The destination path in which the backup copy will be stored on the ex-
ternal computer is displayed.
–
Press “Y” to start the backup process.
The actual backup process is now carried out by Norton Ghost
t
.
The following information is displayed in the message window that opens:
–
The progress of the data transfer is displayed.
–
The paths are displayed.
–
The volume of data to be transferred is displayed.
Size of backup copy with compressing: 4.8GB hard disk –> approx. 330MB
image file.
Time for transfer: approx. 15min.
15 SW Installation/Update and Data Backup
Содержание SINUMERIK 840Di