System Hardware Manual

Issue 1.2 January 2015

Содержание Univerge SV9100

Страница 1: ...System Hardware Manual Issue 1 2 January 2015...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...stem Specifications Section 1 General Information 2 1 Section 2 System Block Diagram 2 1 Section 3 Maximum System Capacities 2 5 3 1 System Configuration SV9100 2 6 Section 4 Power Based Calculator Ch...

Страница 4: ...Music via ACI 2 25 5 6 6 External Paging Audio 2 25 5 6 7 External Tone Ringer Night Chime Output 2 25 5 6 8 SMDR Output 2 26 5 6 9 PC Connection 2 26 5 6 10 Relay Contact 2 26 5 7 Battery Backup 2 26...

Страница 5: ...ng the 9 5 Base CHS2UG Chassis 3 16 1 2 1 Install Grounding on 9 5 Chassis 3 17 1 2 2 Install AC Power Cord 9 5 Gateway or Base Chassis 3 18 1 2 3 Install Additional Blades 9 5 Gateway or Base Chassis...

Страница 6: ...Batteries 19 CHS2UG Chassis 3 53 6 2 Installing the External Batteries 19 CHS2UG Chassis 3 58 6 2 1 Floor Mounting the CHS LARGE BATT BOX 3 58 6 2 2 Battery Installation 3 60 6 2 3 CHS LARGE BATT BOX...

Страница 7: ...alling an Extension or Trunk Blade 4 4 2 2 1 Installing the Blades 4 4 2 2 2 Order of Installing Extension Blades 4 5 2 2 3 Order of Installing Trunk Blades 4 6 2 2 3 1 Installing GCD 4COTA GCD 4DIOPB...

Страница 8: ...M or Music on Hold MOH 4 22 3 1 3 Switch Settings 4 23 3 1 4 LED Indications 4 23 3 1 5 Connectors 4 25 3 2 GPZ IPLE Voice over IP Daughter Board 4 27 3 2 1 Description 4 27 3 2 2 Installation 4 28 3...

Страница 9: ...4 Port 8 Port SLI Daughter Boards 4 44 4 4 1 Description 4 46 4 4 2 Installation 4 47 4 4 3 Connectors 4 48 4 5 GCD LTA Dterm SLT Combination 4 49 4 5 1 Description 4 49 4 5 2 Installation 4 50 4 5 3...

Страница 10: ...rs 4 68 5 4 4 Termination Switch Settings 4 69 5 5 GCD 4DIOPB DID OPX Interface 4 70 5 5 1 Description 4 70 5 5 2 Installation 4 71 5 5 3 LED Indications 4 71 5 5 4 Connectors 4 72 5 6 GCD PRTA PRI In...

Страница 11: ...onnectors 4 89 6 1 4 1 RS 232 Interface 4 89 6 1 4 2 DB9 to 6 pin Modular RS 232 Adapter 4 90 6 1 4 3 RS 232 Serial Cable DTE 4 90 6 1 4 4 RS 232 Serial Cable DCE 4 91 6 1 4 5 USB Interface 4 91 6 1 4...

Страница 12: ...line Terminals Section 1 General Description 5 1 Section 2 DT300 DT400 Series Digital Multiline Terminals 5 14 2 1 DT300 Series Digital MultilineTerminals 5 14 2 1 1 DTL 2E 1 BK TEL 5 14 2 1 2 DTL 6DE...

Страница 13: ...TL 12DG 3 BK TEL 5 33 3 1 8 ITL 12PA 1 BK TEL 5 34 3 1 9 ITL 24D 1 BK TEL ITL 24D 1 WH TEL 5 35 3 1 10 ITL 32D 1 BK TEL ITL 32D 1 WH TEL 5 36 3 1 11 ITL 320C 1 BK TEL 5 37 3 2 DT800 Series IP Multilin...

Страница 14: ...5 57 4 7 1 Installing the Numbered Keypad on a Multiline Terminal 5 59 4 7 2 Configuring the Digital Telephone for the Numbered Keypad 5 61 4 7 3 Configuring the IP Telephone for the Numbered Keypad 5...

Страница 15: ...stalling the 8LKI LD L UNIT 5 83 5 2 4 DCL 60 1 DCZ 60 2 CONSOLE BK WH 5 86 5 2 4 1 Installing the DCL 60 1 DCZ 60 2 CONSOLE 5 87 5 2 5 LCD BL L BK UNIT LCD BL L WH UNIT 5 91 5 2 6 LCD BL Z UNIT BK WH...

Страница 16: ...e and Replace Handset Battery 5 118 Section 8 Bluetooth Hub Adapter 5 119 8 1 Bluetooth Hub Adapter BHA Features 5 119 8 1 1 Installing the BHA L UNIT 5 119 8 1 2 Pairing a Bluetooth Device and Multil...

Страница 17: ...dard Wall Plate 5 137 10 10 Mounting the Base Directly to the Wall 5 140 10 11 Wall Mounting the Charging Unit 5 142 10 12 Attaching and Removing the Belt Clip 5 143 10 13 Installing the Handset Batte...

Страница 18: ...nd Door Box Page Relays 6 17 6 1 External Page Relays 6 17 6 2 Door Box External Page Relay Contacts 6 18 6 2 1 Connecting a Contact Relay Device to a Door Box External Page Relay 6 18 Section 7 Exter...

Страница 19: ...1 11 3 ADA L UNIT 6 33 11 3 1 ADA L UNIT Switch Settings 6 34 11 3 2 Installing the ADA L UNIT 6 35 11 3 3 ADA L UNIT Connection 6 37 11 3 3 1 ADA L UNIT Connection for Recording Only 6 37 11 3 3 2 AD...

Страница 20: ...___________________________________________________________________________ xviii Table of Contents ___________________________________________________________________________________ 12 3 Installing...

Страница 21: ...ns regarding proper disposal procedures The UNIVERGE SV9100 GCD CP10 provides memory backup for approximately three years The Lithium battery should be replaced every two years IMPORTANT SAFEGUARDS FO...

Страница 22: ...ies must be returned to an approved nickel cadmium or sealed lead battery recycler This may be where the batteries were originally sold or a local seller of automotive batteries Contact your local was...

Страница 23: ...ific features should match the supported features of the system For an overview of the supported features refer to the detailed documentation that comes with this system contact your local NEC represe...

Страница 24: ...imposed for illegal disposal of electrical and electronic products via the general municipal waste stream In order to facilitate separate disposal and environmentally sound recycling arrangements hav...

Страница 25: ...existing Time Division Multiplexing TDM based infrastructure such as analog telephones digital telephones DT300 DT400 series analogue networks and digital networks T1 E1 ISDN etc The 9 5 Gateway or B...

Страница 26: ...and for CCIS Remote Unit connections with other SV9100 On the other hand the TDM switching is provided for communications between legacy stations trunks Connection between IP network and legacy netwo...

Страница 27: ...only in an initial supply line trunk interfaces can be easily expanded by adding the daughter blade The maximum number of ports for the line trunk blades is 8 16 ports with daughter blade respectivel...

Страница 28: ...Issue 1 2 UNIVERGE SV9100 1 4 Introduction to SV9100 provides an enhanced user interface A Quick Setup tool provides easy setup system data programming for a basic system configuration in shorter time...

Страница 29: ...Blank Slot Cover Set CHS2UG JOINT BRACKET KIT Upper Joint Bracket for 6 slot Chassis CHS2UG RACK MOUNT KIT Rack Mount for CHS2UGG Chassis CHS2UG WALL MOUNT KIT Wall Mount Set for CHS2UG Chassis CHS2U...

Страница 30: ...tion Interface GCD 4COTA COT 4 port Loop Start Trunks GPZ 4COTE COTDB 4 port Loop Start Trunks on GCD 4COTA GCD 4LCA LC 4 port Single Line Telephone Interface GPZ 4LCA LCDB 4 port Single Line Telephon...

Страница 31: ...RS RVS 4S CA G RS 232C Cable reverse 13 1 ft 4 0m RS PRT 15S CA F RS 232C Cable printer 49 2 ft 15 0m BUS CABLE Bus Cable AC CORD AC Power Cable CHS2U BATT CA INT CHS2UG Battery Cable for Internal Bat...

Страница 32: ...it Backloght LCD for Digital Telephone Table 1 7 Digital Multiline Terminal DT400 Series Equipment List Equipment Name Equipment Description DTZ 2E 3 BK TEL Economy Digital 2 button Telephone No Displ...

Страница 33: ...Value IP 12 button Telephone with Power Failure Adapter ITL 8LD 1 BK TEL ITL 8LD 1 WH TEL Value IP 8 Line Key Display Telephone Value IP Telephone DESI less ITL 320C 1 BK TEL Sophisticated Telephone 8...

Страница 34: ...e DESI DCL 60 25 PKG DESI Sheet for 60DSS 1 Part Sheet 25 Package DESI ITL DTL SIDE 25 PKG DESI Sheet for Clear Side Panel Left and Right Part Sheet 25 Package DESI ITL DTL SIDE LCDV 25 PKG DESI Sheet...

Страница 35: ...ver Kit 8 button LKPANEL 60BTN L BK UNIT LKPANEL 60BTN L WH UNIT Spare Plastic Cover Kit 60 button DTL Value Base 1 unit Digital Base LCDD S L BK UNIT LCDD S L WH UNIT Digital Standard Telephone LCD T...

Страница 36: ...NMETA UNIT Color LK panel 12button for Value GunMetallic 1 set consists 10 of panels LKPANEL 12BTN L L Green M UNIT Color LK panel 12button for Value Lime Green Metallic 1 set consists 10 of panels LK...

Страница 37: ...pair of panels A pair includes 1 left and 1 right panel PANEL BIO VLCD L UNIT BIO side panel for Value LCD 1 set consist of 10 pair of panels A pair includes 1 left and 1 right panel PANEL BIO SLCD L...

Страница 38: ...Adapter for GBA L UNIT BS S HOTEL L BK UNIT Standard Hotel function keypad for Sophi BK with Blank D F panel CG Directory Card Holder CG Directory Card Unit DTL 8R 1 Cordless DECT Cordless Handset and...

Страница 39: ...m Hardware Manual 1 15 16LK Z BK UNIT 16LK Z WH UNIT 16 button Line Key Unit DTZ 8R 1 Cordless DECT Cordless Handset and Base Unit Table 1 11 DT400 DT800 Series Optional Equipment List Continued Equip...

Страница 40: ...Issue 1 2 UNIVERGE SV9100 1 16 Introduction to SV9100...

Страница 41: ...of Abbreviations lists abbreviations used in the diagram Table 2 1 List of Abbreviations Abbreviation Description Contact Center Automatic Call Distribution ADA Ancillary Device Adapter APR Analog Po...

Страница 42: ...l T1 GBA GigaBit Adapter GSWU Power over Ethernet Gigabit Switch IDF Intermediate Distribution Frame IPT IP Trunk P2P CCIS on CPU ISDN Integrated Service Digital Network LAN Local Area Network LC Sing...

Страница 43: ...ade SERIAL Serial Port on CPU SLT Single Line Telephone SMDR Station Message Detail Recording TDSW Time Division Switch on CPU USB Universal Serial Bus on CPU GCD VM00 UMS Blade Server Blade SV9100 on...

Страница 44: ...Issue 1 2 UNIVERGE SV9100 2 4 SV9100 System Specifications Figure 2 1 SV9100 System Block Diagram...

Страница 45: ...um of three additional chassis onto the controlling chassis This provides a maximum of 24 slots and 368 digital terminals To obtain a the maximum port capacity of 512 ports two systems can be linked t...

Страница 46: ...terminals Through IP connection and use of additional 19 chassis the system can be expanded to a maximum of 896 ports The 19 chassis consists of a controlling chassis chassis with CPU blade and the a...

Страница 47: ...re Manual 2 7 Figure 2 3 19 Controlling and Expansion Chassis 6 Slots 18 Slots IP Connection 24 Slots The 9 5 chassis graphics shown in the horizontal position are for illustration purposes only Actua...

Страница 48: ...hassis x4 Comments Number of Slot s for Interface Package 5 Slots 6 Slots 23 Slots Chassis CHS2UG 19 Chassis 1 3 4 Virtual slot in NetLink is limited to maximum of 240 Expansion GPZ BS10 3 jack Expans...

Страница 49: ...rdware 9 5 Chassis 19 Chassis with CPU 19 Chassis without CPU 19 Chassis x4 Comments Number of Slot s for Interface Package 3 Slots 5 Slots 6 Slots 23 Slots Common Control Blades GCD CP10 1 1 0 0 GPZ...

Страница 50: ...A 4 Loop Start Trunk 2 5 6 23 GPZ 4COTE 4 Loop Start Trunk Daughter Board 2 5 6 23 GCD 4DIOPB 4 DID OPX 1 5 6 23 When installed as a DID blade GCD 4ODTA 4 E M 2 5 6 23 GCD PRTA 1 Primary Rate Interfac...

Страница 51: ...00 Voice Mail and Server 1 1 1 1 Maximum of One per system PZ BZ10 for Controlling Chassis 0 1 0 0 PZ BZ11 for Expansion Chassis 0 1 3 Table 2 4 Maximum System Capacities Blades Continued Hardware 9 5...

Страница 52: ...LTA can have a GPZ 2BRIA or the GPZ 4COTE daughter board mounted Table 2 5 Daughter Board Combinations Daughter Board GPZ 2BRIA GPZ 4COTE GPZ 4LCA GPZ 8LCE GPZ 8DLCB Controlling Chassis GCD LTA 8 Dig...

Страница 53: ...ber of Package Installed Refer to Table 2 8 Terminal Power Factor below for the Terminal Adapter power chart Table 2 6 Board Power Factor Board Power Factor Total 7 Item Power Factor GCD CP10 1 GCD VM...

Страница 54: ...2 button w BCH 3 Value 12 button w PSA 2 DT300 DT400 Series Optional DSS Console 2 Power Save Adapter PSA 1 2 Line Key Unit 8 or 16 button 0 Ancillary Device Adapter ADA 2 Analogue Port Adapter w Ring...

Страница 55: ...ITL 24BT 1 TEL Class 2 130mA 6 2W 235mA 5 6W 0 0W 0 0W ITL 8LDE 1 TEL Class 1 68mA 3 3W 122mA 2 9W 68mA 3 3W 122mA 2 9W ITL 6DE 1 TEL Class 1 68mA 3 3W 122mA 2 9W 68mA 3 3W 122mA 2 9W ITL 2E 1 TEL Cl...

Страница 56: ...L is changed to ITZ 8LD 3 TEL or ITZ 24D 3 TEL Table 2 10 IP Terminal Power Chart Continued DT800 IP Terminal IEEE802 3af Class Label Indication Maximum Current with All Options Maximum Current Withou...

Страница 57: ...3 DT400 Series Loop Resistance and Cable Length Table 2 14 DT700 Series Loop Resistance and Cable Length Table 2 15 DT800 Series Loop Resistance and Cable Length Table 2 16 Cable Connection Between th...

Страница 58: ...DTZ 6DE 3 BK TEL 1 969 ft 600m 6 562 ft 2000m DTZ 8LD 3 BK TEL DTZ 8LD 3 WH TEL 1 969 ft 600m 6 562 ft 2000m DTZ 12D 3 BK TEL DTZ 12D 3 WH TEL 1 969 ft 600m 6 562 ft 2000m DTZ 24D 3 BK TEL DTZ 24D 3...

Страница 59: ...0 m ITL 32D 1 BK TEL ITL 32D 1 WH TEL Cat 5 Cat 6 Ethernet 328 1 ft 100m ITL 32OC 1 BK TEL Cat 5 Cat 6 Ethernet 328 1 ft 100m Table 2 15 DT800 Series Loop Resistance and Cable Length Terminal or Adapt...

Страница 60: ...CA Twisted Pair 600ohms including the SLT 3 281 ft 1 000m with 26 AWG 4 920 ft 1 500m with 24 AWG 8 202 ft 2 500m with 22 AWG OPX Twisted Pair 1 500ohms or less including the SLT 13 123 ft 4 000m with...

Страница 61: ...sis can refer to either 9 5 or 19 chassis Output Power Base chassis 130W Expansion chassis 130W total 520W AC Input I Base chassis 1 15A Expansion chassis 1 15A total 4 6A VA 230V Base chassis 276VA E...

Страница 62: ...Humidity 10 90 RH Blades GCD 4LCA with GPZ 4LCAdaughter board GCD 8LCA with GPZ 8LCE daughter board GCD 4COTAwith GPZ 4COTE daughter board GCD PRTA Operating Temperature 0 C 40 C Recommended Long Ter...

Страница 63: ...gth From Multiline Terminal to GCD 8DLCA 23 bits From GCD 8DLCA to Multiline Terminal 23 bits Data Transmission Rates Between GCD 8DLCA and Multiline Terminal 184K bps voice and signaling Scanning Tim...

Страница 64: ...V9100 system Pulse Rate 10 0 5 pps 20 1 0 pps Percent Break 60 1 5 Interdigit Interval 0 pps 20 pps 770 ms 830 ms 5 6 2 Dual Tone Multifrequency DTMF Address Signaling DTMF signaling includes push but...

Страница 65: ...by LAN PC by LAN 5 6 4 Music Source for Music on Hold via Chassis Auxiliary Input 0 6V PPS Signal Level Input Impedance 600 5 6 5 Music Source for Station Background Music via ACI Auxiliary Input 0 6...

Страница 66: ...power failure the system can be backed up using the CHS2UG BATT MTG KIT for a backup time of 10 minutes or one of the CHSG LARGE BATT SETs for a backup time ranging from 45 180 minutes 5 7 2 Memory Ba...

Страница 67: ...kg 0 12 in 3 mm 2 56 in 65 mm 1 22 in 31 mm GCD LTA 6 70 oz 0 19 kg 0 98 in 25 mm 5 71 in 145 mm 7 09 in 180 mm CHS LARGE BATT BOX 352 7 oz 10 kg 23 23 in 590 mm 17 72 in 450 mm 10 43 in 265 mm CHSG L...

Страница 68: ...240 mm 7 68 in 195 mm GCD 4ODTA 8 25 oz 0 234 kg 0 98 in 25 mm 9 45 in 240 mm 7 68 in 195 mm GCD RGA 10 05 oz 0 285 kg 0 98 in 25 mm 5 71 in 145 mm 7 68 in 195 mm GCD VM00 7 76 oz 0 22 kg 0 98 in 25 m...

Страница 69: ...1 3 kg 4 29 in 109 mm 7 6 in 183 mm 10 16 in 258 mm DTL 12PA 1 BK TEL 45 6 oz 1 3 kg 4 41 in 112 mm 7 6 in 183 mm 10 16 in 258 mm DTL 12D 1 BK TEL DTL 12D 1 WH TEL 42 33 oz 1 2 kg 4 39 in 111 7 mm 7...

Страница 70: ...oz 1 4 kg 4 41 in 112 mm 7 05 in 179 mm 10 94 in 278 mm ITL 12DG 3 BK TEL 45 86 oz 1 3 kg 4 41 in 112 mm 7 05 in 179 mm 10 16 in 258 mm ITL 32D 1 BK TEL ITL 32D 1 WH TEL 45 6 oz 1 3 kg 4 41 in 112 mm...

Страница 71: ...137 mm 8 82 in 224 mm DCZ 60 2 BK CONSOLE DCZ 60 2 WH CONSOLE 27 50 oz 0 78 kg 3 15 in 80 mm 8 27 in 210 mm 9 84 in 250mm DP D 1A Doorphone 7 05 oz 0 2 kg 5 12 in 130 mm 3 89 in 98 mm 1 12 in 28 5 mm...

Страница 72: ...77 mm 3 03 in 77 mm 2 40 in 61 mm 0 88 oz 0 025 kg 2 25 in 57 15 mm 1 5 in 38 1 mm 1 03 in 26 16 mm G566 Wireless Handset Charger AC Adapter 4 34 oz 0 123 kg 5 63 in 143 mm 1 97 in 50 mm 0 79 in 20 m...

Страница 73: ...line trunk blade Single Line Telephone Interface Digital multiline terminal Interface Central Office Trunk ISDN PRI Interface etc In skin Application Blades In skin UMS In Skin Router etc It also hous...

Страница 74: ...t View Figure 3 2 CHS2UG Chassis Rear View Do not remove or install blades with the power on Universal Slot for Legacy Line Trunk blades and Application blades six slots When used as controlling chass...

Страница 75: ...e 1 1 2 Installing Expansion Blades in the 19 Chassis Optional When adding additional chassis to the system to expand the capacity a GPZ BS10 must be installed in the Controlling Chassis and a GPZ BS1...

Страница 76: ...1 is installed in the Expansion bay of the Expansion Chassis which does not have a CPU The Expansion cable connects the Controlling Chassis and its GPZ BS10 interface to the second third and fourth GP...

Страница 77: ...Locate the door positioned on the left end expansion bay of the Controlling Chassis refer to Figure 3 7 GPZ BS10 Expansion Bay in Controlling Chassis on page 3 6 Table 3 1 GPZ BS10 GPZ BS11 Connector...

Страница 78: ...t side of the chassis pull cover outward to expose the expansion bay 4 Pull the cover toward you to remove Cover must be removed prior to installation of GPZ BS10 blade Figure 3 7 GPZ BS10 Expansion B...

Страница 79: ...S10 blade into the chassis until resistance back plane is felt 7 Gently push until the blade seats and install the supplied retaining screw 8 Align the door tabs with hinges and reattach the cover ref...

Страница 80: ...er 1 1 2 3 Install the GPZ BS11 Expansion Blade in the CHS2UG Expansion Chassis Figure 3 11 GPZ BS10 Blade Installed Figure 3 12 GPZ BS10 Installed Cover Closed Figure 3 13 f Components For the Expans...

Страница 81: ...left side of the chassis pull cover outward to expose the expansion bay refer to Figure 3 15 Open Expansion Chassis Cover on page 3 9 4 Pull the cover toward you to remove Cover must be removed to ins...

Страница 82: ...the guides located within the expansion bay 6 Slide the GPZ BS11 blade into the chassis until resistance back plane is felt 7 Gently push until the blade seats and install the supplied retaining screw...

Страница 83: ...ver 9 Close the GPZ BS11 blade cover 1 1 2 4 Connect the Controlling and Expansion Chassis Figure 3 18 GPZ BS11 Blade Installed Figure 3 19 GPZ BS11 Installed Cover Closed Installment of the GPZ BS10...

Страница 84: ...ch Expansion Chassis CN2 connector on the GPZ BS11 blade see Figure 3 21 System Expansion Cabling on page 3 13 Attach the opposite end to the CN2 CN3 or CN4 connector on the GPZ BS10 of the Controllin...

Страница 85: ...he back of the chassis Each chassis CHS2UG in the system must be grounded separately using the procedure listed below 1 Ensure each Chassis is powered down and unplugged 2 Ground each chassis by conne...

Страница 86: ...is Each chassis CHS2UG in the system must be grounded separately using the procedure listed below 1 Ensure all Controlling and Expansion Chassis are powered down and unplugged 2 Ground each chassis by...

Страница 87: ...er Cords on 19 Chassis 1 Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis Figure 3 23 19 Chassis Grounding Lug Multiple Chassis FG Lugs Elect...

Страница 88: ...apter 4 2 6 Powering Up the SV9100 on page 4 9 1 2 Installing the 9 5 Base CHS2UG Chassis The CHS2UG chassis have three universal blade slots for station trunk and optional blades Before proceeding wi...

Страница 89: ...all Grounding on 9 5 Chassis 1 Ensure the 9 5 chassis is powered off and the AC power cord is unplugged 2 Ground the chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis...

Страница 90: ...en the GCD CP10 blade is installed in slot 1 of the 9 5 Base Chassis it is called the controlling chassis The 9 5 Base chassis provides up to 16 trunk ports or 32 extension ports An Expansion Chassis...

Страница 91: ...low for required spacing before drilling 2 Mark and drill the six holes required for a wall installation 3 Align screw holes in wall mount brackets with drilled holes 4 Using six screws secure the two...

Страница 92: ...Issue 1 2 UNIVERGE SV9100 3 20 Installing the SV9100 Chassis Figure 3 29 Install Wall Mount Brackets with Screws...

Страница 93: ...IVERGE SV9100 Issue 1 2 System Hardware Manual 3 21 5 Using four screws secure the metal fittings on the Left and Right sides of the 19 chassis Figure 3 30 Securing Metal Fittings to Chassis with Scre...

Страница 94: ...the metal fitting with the upper wall mount bracket The lower metal fitting rests against the lower wall mount bracket Secure the metal fitting and upper wall mount bracket with a single screw Figure...

Страница 95: ...re the metal fitting to the lower wall mount bracket Refer to figure below for screw location 8 Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single sc...

Страница 96: ...Issue 1 2 UNIVERGE SV9100 3 24 Installing the SV9100 Chassis Figure 3 33 Attach Cable Support Bracket to Lower Wall Mount Bracket...

Страница 97: ...aragraph 2 1 Installation and Safety Precautions on page 4 3 for installation of blades 2 2 Wall Mounting the 9 5 Chassis When wall mounting the chassis ensure the wall can support the weight of the c...

Страница 98: ...clearance between the wall and the CHS2UG CHS2UG E chassis is approximately 1 7 in 43mm due to height of the wall mounting bracket p The chassis must be mounted horizontally with the slot front side o...

Страница 99: ...rill four holes marked A B C and D 3 Mount Anchor bolts locally procured in holes A and B drilled in step 2 Because the bracket upper will be hooked onto the head of the anchor bolts allow the head to...

Страница 100: ...Issue 1 2 UNIVERGE SV9100 3 28 Installing the SV9100 Chassis Figure 3 36 Anchor Bolt from Wall 9 5 Chassis...

Страница 101: ...2 System Hardware Manual 3 29 2 2 2 1 Wall Mounting the CHS2UG without the CHS2UG B Small Batt Box 1 Align the bracket halves refer to Figure 3 37 Wall Mounting Brackets Option 2 Figure 3 37 Wall Mou...

Страница 102: ...sis CHS2UG Install 2 M4 x 14 screws M4 x 14 screws are provided with the WALL MOUNT BRACKET 3 Align holes G and H on the MV bracket lower with holes on the 9 5 inch Basic Chassis CHS2UG Install 2 M4 x...

Страница 103: ...aragraph 1 3 Installing the 9 5 Chassis on page 3 18 for complete details on grounding the system 6 Refer to 2 1 Installation and Safety Precautions on page 4 3 for installation of blades 2 2 2 2 Wall...

Страница 104: ...9100 3 32 Installing the SV9100 Chassis Mounting Brackets Option 2 2 Turn the brackets upside down and remove four screws refer to Figure 3 42 Brackets Small Batt Box on page 3 33 Figure 3 41 Wall Mou...

Страница 105: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 3 33 Figure 3 42 Brackets Small Batt Box...

Страница 106: ...Issue 1 2 UNIVERGE SV9100 3 34 Installing the SV9100 Chassis 3 Align the holes marked as R and F Figure 3 43 Reposition Brackets Small Batt Box...

Страница 107: ...35 4 Install the four screws previously removed 5 Align the brackets with the holes on the sides of the 9 5 inch Basic Chassis CHS2UG Install 2 M4 x 14 screws Figure 3 44 Install Screws Small Batt Bo...

Страница 108: ...he system 8 Refer for installation of the power cord to Chapter 6 paragraph 2 1 Installation and Safety Precautions on page 4 3 for installation of blades SECTION 3 FLOOR MOUNTING THE CHASSIS 3 1 Floo...

Страница 109: ...bolts locally procured 2 Mark and drill the four holes required to install the CHS BASE UNIT 3 Using anchor bolts secure the CHS BASE UNIT to the floor Refer to figure below for screw location Figure...

Страница 110: ...2 UNIVERGE SV9100 3 38 Installing the SV9100 Chassis 4 Install the five rubber feet to the bottom of the chassis 5 Position the chassis on top of the CHS BASE UNIT Figure 3 49 Install Rubber Feet 19...

Страница 111: ...for complete details on grounding the system 8 Refer to 1 1 5 Install AC Power Cords on 19 Chassis on page 3 15 to continue installation of the chassis or Chapter 6 paragraph 2 1 Installation and Safe...

Страница 112: ...both ends of the 19 chassis and the CHS BASE UNIT Refer to figure below 3 Connect the ground wire to all chassis Refer to 1 1 3 Install Grounding on 19 Chassis on page 3 13 for complete details on gro...

Страница 113: ...CHS2UG Chassis A single or multiple chassis can be stand mounted Controlling and Expansion chassis can be stand mounted using the CHS2UG STAND KIT K and CHS2UG STAND KIT EXT 4 1 1 CHS2UG Chassis Insta...

Страница 114: ...ure the CHS2UG STAND KIT K to the floor refer to figure below Figure 3 54 Secure CHS2UG Chassis to CHS2UG STAND KIT K with Screws To prevent possible damage to the 19 chassis due to falling NEC recomm...

Страница 115: ...nstall AC Power Cords on 19 Chassis on page 3 15 to continue installation of the chassis or Chapter 6 paragraph 2 1 Installation and Safety Precautions on page 4 3 for installation of blades 4 1 2 Mul...

Страница 116: ...stalling the SV9100 Chassis 1 Install the five rubber feet to the bottom of each chassis 2 Each additional chassis requires a CHS2UG STAND KIT EXT to be installed refer to figure below Figure 3 56 Att...

Страница 117: ...ystem Hardware Manual 3 45 3 Metal brackets from the CHS2UG JOINT BRACKET KITs are required to secure the top end of the chassis with screws See figure below Figure 3 57 Install Additional CHS2UG STAN...

Страница 118: ...efer to 1 1 5 Install AC Power Cords on 19 Chassis on page 3 15 to continue installation of the chassis or Chapter 6 paragraph 2 1 Installation and Safety Precautions on page 4 3 for installation of b...

Страница 119: ...bes this procedure 1 Position the 9 5 Base Chassis so that the EXIFU slot is on top 2 Align the Base unit with holes A B C and D on the lower side of the CHS2UG B chassis Attach with the provided M4 x...

Страница 120: ...t brackets can be mounted on the left or right side on tabs d e f g h and i of the stand unit When attaching the stand unit to the 9 5 Base chassis ensure the shape of the stand unit aligns with the s...

Страница 121: ...remaining bracket on tabs j k l m n and o on the opposite side of the stand unit 5 Align the support bracket with holes P and Q on the stand unit brackets and secure using the two M3 x 8 screws provid...

Страница 122: ...on of the power cord or Chapter 6 paragraph 2 1 Installation and Safety Precautions on page 4 3 for installation of blades SECTION 5 RACK MOUNTING THE CHASSIS 5 1 Rack Mounting the 19 CHS2UG Chassis A...

Страница 123: ...er to figure below for the 19 chassis Repeat for additional chassis mounting 4 Carefully slide the chassis into desired location in the rack Make sure the hooks on the mounting bracket are inserted in...

Страница 124: ...ng the screws supplied Repeat for additional chassis mounting 6 Connect the ground wire to all chassis Refer to 1 1 3 Install Grounding on 19 Chassis on page 3 13 for complete details on grounding the...

Страница 125: ...he internal battery and an external battery with CHS LARGE BATT BOX 6 1 Installing the Internal Batteries 19 CHS2UG Chassis An internal battery source using two batteries can be installed using the CH...

Страница 126: ...Issue 1 2 UNIVERGE SV9100 3 54 Installing the SV9100 Chassis 4 Remove access panel containing the fan Refer to figures below Figure 3 69 Removing Access Panel Figure 3 70 Access Panel Removed...

Страница 127: ...plied screw install cable guide in chassis 7 Install two 2 3 AH 12V batteries locally procured into the CHS2UG BATT MTG KIT Figure 3 71 Secure Cable in Support Bracket Figure 3 72 Installing Cable Sup...

Страница 128: ...he SV9100 Chassis 8 Using the supplied screws secure the brackets to the CHS2UG BATT MTG KIT refer to figure above 9 Connect the provided battery cables to the batteries Figure 3 73 Installing Two Bat...

Страница 129: ...al 3 57 10 Connect CHS2UG BATT CABLE INT to battery connector 11 Install CHS2UG BATT MTG KIT into CHS2UG chassis and tighten the retaining screws Figure 3 75 Connecting CHS2UG BATT CABLE INT Figure 3...

Страница 130: ...during a power failure CHS LARGE BATT BOX Backup time Three Hours for 30 Terminals 6 2 1 Floor Mounting the CHS LARGE BATT BOX Figure 3 77 Installing the Access Panel Table 3 2 CHSG LARGE BATT BOX Cap...

Страница 131: ...all the CHS BASE UNIT m Because of injury from falling equipment wall mounting the CHSG LARGE BATT BOX is not recommended m Mounting the CHSG LARGE BATT BOX directly on the floor is not recommended m...

Страница 132: ...GE BATT BOX on top of the CHS BASE UNIT 5 Secure the CHS LARGE BATT BOX to the CHS BASE UNIT using the CHS2UG JOINT BRACKET KIT Refer to figure below 6 2 2 Battery Installation 1 Loosen screw on front...

Страница 133: ...rom front of Battery Tray Suppressor 4 Slide Battery Tray Suppressor outward to remove 5 Slide Battery Tray s out of CHS LARGE BATT BOX 6 Loosen two screws and remove the Battery Tray Cover Figure 3 8...

Страница 134: ...nnection guide below for connection of battery cable to battery terminals Repeat for additional battery connection 9 Install batteries into Battery Tray Refer to figure below Figure 3 83 Removing Batt...

Страница 135: ...over and tighten the two screws 13 Slide the Battery Trays into the CHS LARGE BATT BOX 14 Install the Battery Tray Suppressor while pulling the Battery Connection Cable s through the cutouts provided...

Страница 136: ...eft until seated and tighten the screw 6 2 3 CHS LARGE BATT BOX to CHS2UG Connection 1 Power down the CHS2UG chassis 2 Disconnect AC power cable from rear of chassis 3 Remove fan access panel from rea...

Страница 137: ...Connection Cable to Battery Connector on rear of Basic and Expansion chassis 5 Connect other end of cable to Battery Connector on rear of CHS LARGE BATT BOX chassis Figure 3 89 Connecting External Ba...

Страница 138: ...nel tab into the rear of the CHS2UG chassis running the Battery Connection Cable through the cutout Secure panel with the retaining screw 7 Connect grounding and AC power cables Figure 3 91 Dual CHSG...

Страница 139: ...dware Manual 3 67 8 Apply power to chassis refer to Chapter 4 2 6 Powering Up the SV9100 on page 4 9 6 2 4 CHS LARGE BATT BOX Fuse Replacement 1 Loosen screw on front of CHS LARGE BATT BOX Figure 3 93...

Страница 140: ...or 3 Slide Battery Tray Suppressor outward to remove 4 Disconnect the Battery Connection Cables from the Fuse Unit 5 Loosen two screws and pull Fuse Unit out of the CHS LARGE BATT BOX 6 Refer to Figur...

Страница 141: ...Slide the Fuse Unit into the and tighten the two screws refer to Figure 3 95 Disconnecting Battery Cables on page 3 68 8 Plug the Battery Connection Cables into the Fuse Unit Figure 3 96 CHSG LARGE B...

Страница 142: ...s during a power failure The short term battery box will power the system for approximately 10 minutes 6 3 1 CHSGW SMALL BATT BOX Installation 1 Power down the CHS2UG chassis 2 Disconnect AC power cab...

Страница 143: ...1 2 System Hardware Manual 3 71 4 Remove the battery connector cap on the Base chassis and connect the battery connection cable Figure 3 99 Installing Battery Cable Assembly Figure 3 100 Installing Ba...

Страница 144: ...V9100 Chassis 5 Remove the two M3 x 8 screws from the Small Battery Box then remove the battery cover 6 Place the two batteries into the Small Battery Box refer to Figure 3 102 Installing Batteries on...

Страница 145: ...ry Box tabs and connect to connectors A and B 8 Insert tabs c and d of the battery cover into slots C and D of the Small Battery Box Secure the cover using two M3 x 8 screws refer to Figure 3 104 Inst...

Страница 146: ...2 UNIVERGE SV9100 3 74 Installing the SV9100 Chassis 9 Pull the battery lock of the Small Battery Box forward to unlock it Figure 3 104 Installing Battery Cover Figure 3 105 Unlocking the Small Batte...

Страница 147: ...Align the Small Battery Box with the grooves at the top and bottom of the Base chassis and slide into position 11 Push the battery lock in then connect the battery cable Figure 3 106 Installing Small...

Страница 148: ...s 3 Unplug battery cables a and b from connectors A and B of the Small Battery Box m Only replace fuses of the same rating m Fuses may be hot use caution when replacing them Replacing fuses without fi...

Страница 149: ...e CHS2U GW chassis during a power failure The long term battery box powers the system for approximately three hours 6 4 1 CHS LARGE BATT BOX Installation To install the batteries in the CHS LARGE BATT...

Страница 150: ...e two prong battery terminal leads refer to Figure 3 110 9 5 Chassis Rear View 4 Connect one end of Battery Connection Cable to Battery Connector on rear of 9 5 chassis 5 Connect other end of cable to...

Страница 151: ...apter 3 section 6 2 4 CHS LARGE BATT BOX Fuse Replacement on page 3 67 SECTION 7 POWER SUPPLY SECTION 8 REMOVE AND INSTALL COOLING FAN If required the cooling fan installed in the CHS2UG chassis can b...

Страница 152: ...hassis To reduce the possibility of electrical shock or damage to equipment NEC recommends powering off the chassis and disconnecting the AC cable from the power source before removing the chassis cov...

Страница 153: ...nstalling replacement fan 8 1 2 Install Cooling Fan 1 Align replacement fan with holes and secure with two screws 2 Install cabling into retention clips 3 Insert access panel hinges into slots on rear...

Страница 154: ...Issue 1 2 UNIVERGE SV9100 3 82 Installing the SV9100 Chassis...

Страница 155: ...HS2U has six slots In the Controlling Chassis the GCD CP10 must be installed in the first slot slot 1 In the CHS2U GW the GCD CP10 must be installed in the first slot slot 1 Slot Locations in the CHS2...

Страница 156: ...Issue 1 2 UNIVERGE SV9100 4 2 Installing the SV9100 Blades Figure 4 1 Chassis CPU and Expansion Slot Locations 19 Controlling Chassis CPU Slot 19 Expansion Chassis GPZ BS11 Slot 9 5 Chassis...

Страница 157: ...und the Controlling and Expansion chassis before installing or removing the blades The Expansion Chassis must be installed with the system power OFF Do not touch the blade components Carry the blade i...

Страница 158: ...Blades To install an extension trunk blade with the system running 1 Insert the blade within the guide rail and push the blade securely into position Tighten the thumb screws on either side of the bla...

Страница 159: ...er board to increase the available ports or go to a higher capacity blade e g GCD 16DLCA may require that the slot be deleted in programming and the blade reinstalled In the following example to add a...

Страница 160: ...must first be undefined in Program 10 03 before the console is connected 2 2 3 Order of Installing Trunk Blades 2 2 3 1 Installing GCD 4COTA GCD 4DIOPB GCD 4ODTB or GCD 2BRIA blades The order in which...

Страница 161: ...ades are installed in the following order the numbering plan below applies Table 4 3 Trunk Blade Installation Order Example Order of Installation Blade Slot Number Blade Line Circuits 1 4 GCD 4COTA wi...

Страница 162: ...e EXCEPT the ones listed below can be removed while the system is powered up To remove any of the blades listed below the system must first be powered down GCD CP10 GPZ BS10 and GPZ BS11 GPZ IPLE To r...

Страница 163: ...and hold the Load button 3 Turn the power switch back on to power the system back up With a multi chassis system turn on the Expansion Chassis power supply then the Controlling Chassis power supply 4...

Страница 164: ...stem This section describes the process of resetting a system that is running Observe the important information listed in below To reset the system 2 6 3 1 Initial Programming The system can be progra...

Страница 165: ...ESIU Blades to be programmed 3 Set the terminal type or option as needed If the system has DSS Consoles Program 30 02 must be used to define DSS extension assignments As the system recognizes the ext...

Страница 166: ...n only hold one customer database each database is saved to a directory called DATA this directory is overwritten if a second database is saved to the same card Each database to be saved will require...

Страница 167: ...the software to the USB Memory Note that a USB Memory can only hold one customer database Each database to be saved requires its own separate USB Drive Use Program 90 04 with the database to be restor...

Страница 168: ...ntil the Status LEDs on the GCD CP10 have the following indications approximately two minutes LED 2 Flashing Red LED 3 Flashing Red LED 4 Flashing Red LED 5 Steady Red 8 Turn the system power off and...

Страница 169: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 15 SECTION 3 COMMON CONTROL BLADES The blades described in this section control the common functions of the chassis...

Страница 170: ...Issue 1 2 UNIVERGE SV9100 4 16 Installing the SV9100 Blades 3 1 GCD CP10 SV9100 Central Processing Unit Figure 4 3 GCD CP10 Blade Layout...

Страница 171: ...CP10 memory The system software can be upgraded as new software becomes available One GCD CP10 blade must be installed in the Controlling Chassis The GCD CP10 functions are Music on Hold tone Circuit...

Страница 172: ...ts maximum 512 virtual extensions Connection for GPZ IPLE Daughter Board Supports TAPI 2 x One Green Status LED Four Red Status LEDs Five diagnostic LEDs which indicate the status of various system fu...

Страница 173: ...r 1GB should be used USB device power consumption is less than 200mA 1W One Gbit Ethernet Port for VoIP function One CompactFlash Card Slot Background Music EXSP Control Port Status LED Two Audio Inpu...

Страница 174: ...is 1 Install the battery on the GCD CP10 The polarity symbol must be on top as illustrated in Figure 4 5 GCD CP10 Battery Installation Figure 4 5 GCD CP10 Battery Installation The chassis power must b...

Страница 175: ...ng the backup battery SRAM data and system clock are initialized Make a backup of the SRAM in advance and configure the system clock after battery replacement Replace the battery every 6 years Contact...

Страница 176: ...supply is OFF then slide the SD card label side up into the slot until it clicks To remove Carefully push on the SD card until it clicks and release Card can be removed from the slot 3 1 2 3 Backgrou...

Страница 177: ...Memory Status Operation Switch S5 Load Switch With a system restart or a system reset while holding the SW1 switch When USB Memory is not installed Cold Start occurs When USB Memory is installed USB...

Страница 178: ...Off Off Off On Steady When USB Memory is Installing System operating normally Off Off Off Off Blinking Boot is starting Off On Off Off Off Initializing the disk or formatting Blinking Blinking Off Ac...

Страница 179: ...n Off Off On Steady When USB Memory is Installing Error Major alarm occured Blinking Blinking Off Off On Steady When USB Memory is Installing Error Minor alarm occured On Off Off Off Off System starti...

Страница 180: ...5 Cable Connector Pin Outs USB Cable Connector J13 Type A Female USB 1 1 2 0 Standard Pin No Signal 1 Vcc 2 D 3 D 4 GND Ethernet Cable Connector J4 RJ 45 10Base T 100Base TX 1000Base T Port Pin No Con...

Страница 181: ...ackets via the IP network and PCM highway The daughter board is installed on the GCD CP10 The IP telephones are connected directly to the IP bus When IP telephones RJ 45 Cable Connector J10 External S...

Страница 182: ...nstalled This daughter board is installed on the GCD CP10 3 2 2 Installation To install a GPZ IPLE on the GCD CP10 1 With the system power off remove the GCD CP10 2 Install the IPLA Daughter board ont...

Страница 183: ...dicator On Red 100Base T link up LINK 1000 D101 1000Base T link speed indicator On Red 1000Base T link up ACT D100 Link activity or data transmission and reception On Green LED lights when link up com...

Страница 184: ...the SV9100 Blades 3 2 5 Connectors The figure below shows a typical connection layout Figure 4 8 Connecting a IPLA Daughter Board to a Network PC illustrates how to connect a VoIP Daughter Board to a...

Страница 185: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 31 Figure 4 8 Connecting a IPLA Daughter Board to a Network PC...

Страница 186: ...N 4 STATION BLADES 4 1 GCD 8DLCA GCD 16DLCA Digital Station Interface 4 1 1 Description These blades provide 8 GCD 8DLCA OR 16 GCD 16DLCA digital extension circuits used for digital telephones DSS con...

Страница 187: ...ard is to be attached do so now Refer to 4 2 2 Installation on page 4 38 2 Each CNx01 connector CN101 CN201 CN301 CN401 is used to connect up to four digital extensions 4 1 3 LED Indications LEDs for...

Страница 188: ...e 4 32 for the location of the connectors on the ESIU blades Flash 1s On The assignment of the unit is refused When you exceed the system capacity When the main software version is not matched Flash 1...

Страница 189: ...61 Cable Connector GCD 8DLCA CN101 ports 1 4 CN201 ports 5 8 GCD 16DLCA CN101 ports 1 4 CN201 ports 5 8 CN301 ports 9 12 CN401 ports 13 16 Pin No Connection 1 T4 Tip for port 4 2 T3 Tip for port 3 3 T...

Страница 190: ...2 GPZ 8DLCB Digital Station Daughter Board 4 2 1 Description The GPZ 8DLCB daughter board provides eight digital extensions This daughter board is installed on the GCD 8DLCA and expands the port capac...

Страница 191: ...able 4 16 GPZ 8DLCB Maximum Upgrade Capacities provides the maximum capacities for the ESIU blades when they are upgraded Table 4 16 GPZ 8DLCB Maximum Upgrade Capacities 19 Chassis with CPU 19 Chassis...

Страница 192: ...CN101 CN201 CN301 CN401 is used to connect up to four digital extensions 4 2 3 GPZ 8DLCB Daughter Board Cable Connection The GPZ 8DLCB blade has connections for CN301 and CN401 Refer to for connector...

Страница 193: ...18 GPZ 8DLCB CN401 Connection RJ 61 Cable Connector CN401 ports 13 16 Pin No Connection 1 T4 Tip for port 16 2 T3 Tip for port 15 3 T2 Tip for port 14 4 R1 Ring for port 13 5 T1 Tip for port 13 6 R2...

Страница 194: ...CA 4 Port 8 Port Single Line Interface 4 3 1 Description The GCD 4LCA GCD 8LCA 4 8SLIU blade provides four 4SLIU analog extension ports or eight 8SLIU analog extension ports used for on premise analog...

Страница 195: ...Connector for GPZ 4LCA GPZ 8LCE Daughter Boards Ring Generator 75Vrms 16Hz 20Hz 25Hz selectable by CM82 04 02 Caller ID Sending Ability Message Wait Lamping Ability 110V DC Cable length 600ohms inclu...

Страница 196: ...fax machine or analog modem make sure to set Program 15 03 03 to 1 special terminal to avoid communication problems The SLIU and SLIDB are categorized as TNV2 With this designation off premise wiring...

Страница 197: ...43 Off On Unit Busy A Channel is busy use another from CH1 CHx Off All channels are idle Flash 100ms On Off Downloading firmware Table 4 20 GCD 4LCA GCD 8LCA LED Indications Continued LED Indication O...

Страница 198: ...wing the location of the connectors and the pin number locations on the SLIU blades 4 4 GPZ 4LCA GPZ 8LCE 4 Port 8 Port SLI Daughter Boards Table 4 21 GCD 4LCA GCD 8LCA RJ 61 Cable Connector Pin Outs...

Страница 199: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 45 Figure 4 12 Installing the GPZ 4LCA Daughter Board...

Страница 200: ...4LCA and GCD 8LCA Blades One extension status LED Two status LEDs Ring Generator 75Vrms 16Hz 20Hz 25Hz selectable by CM82 04 02 Caller ID Sending Ability Message Wait Lamping Ability 110Vdc Constant c...

Страница 201: ...aughter Board on page 4 45 2 Position the SLIDB CN1 connector over the CN4 connector on the SLIU blade Press the boards together ensuring the plastic spacers lock in place Refer to Figure 4 12 Install...

Страница 202: ...ghter Board on page 4 45 for illustrations showing the location of the connectors on the SLIDB blades Table 4 23 GPZ 4LCA GPZ 8LCE RJ 61 Cable Connector Pin Outs RJ 61 Cable Connector 48SLIDB CN2 port...

Страница 203: ...nation 4 5 1 Description The Digital Station SLT Combination blade provides eight Digital Station ports and two analog ports This blade allows for either a GPZ 4COTE analog trunk daughter board or PZ...

Страница 204: ...ing a fax machine or analog modem make sure to set Program 15 03 03 to 1 special terminal to avoid communication problems The SLIU and SLIDB are categorized as TNV2 With this designation off premise w...

Страница 205: ...le 4 24 GCD LTA LED Indications LED Indication Operation Status Remarks Live LED Green Busy LED Red On On System Initializing Flash 1s On The assignment of the unit is refused When you exceed the syst...

Страница 206: ...le 4 25 GCD LTA RJ61 Cable Connector Pin Outs RJ61 Cable Connector Digital CN101 ports 1 4 Digital CN102 ports 5 8 Pin No Connection 1 T4 T8 Tip for port 4 or 8 2 T3 T7 Tip for port 3 or 7 3 T2 T6 Tip...

Страница 207: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 53 SECTION 5 TRUNK BLADES 5 1 GCD 4COTA 4 Loop Start Interface Figure 4 14 GCD 4COTA Blade...

Страница 208: ...power failure circuits CN3 however are not polarity sensitive Table 4 26 GCD 4COTA Maximum Upgrade Capacities provides the maximum capacities for the 4COIU blades when they are upgraded Table 4 26 GCD...

Страница 209: ...n and LED and Operational status Refer to Figure 4 14 GCD 4COTA Blade on page 4 53 for the location of the LEDs on the blades Table 4 27 GCD 4COTA LED Indications LED Indication Operation Status Remar...

Страница 210: ...e connectors on the 4COIU blades Table 4 28 GCD 4COTA RJ 61 Cable Connector Pin Outs RJ 61 Cable Connector CN2 Trunks The CN2 connector is polarity sensitive tip to tip ring to ring Pin No Connection...

Страница 211: ...4COTE 4 Loop Start Interface Daughter Board 5 2 1 Description The GPZ 4COTE blade provides GPZ 4COTE Four analog loop start trunk circuits Four Caller ID Circuits Connector for COIU Blade Connector fo...

Страница 212: ...vides the maximum capacities for the ESIU blades when they are upgraded Table 4 29 GPZ 4COTE Maximum Upgrade Capacities 19 Chassis with CPU 19 Chassis without CPU 19 Chassis x4 Networked Chassis 5 6 2...

Страница 213: ...he GPZ 4COTE blade refer to Figure 4 15 Installing the GPZ 4COTE Daughter Board on page 4 57 5 2 3 Connectors Table 4 30 GPZ 4COTE RJ 61 Cable Connector Pin Outs on page 4 59 shows the pin outs for th...

Страница 214: ...g to CD LTB GCD LTA Blade The CN2 connector is polarity sensitive tip to tip ring to ring Pin No Connection 1 Circuit 4 Tip 2 Circuit 3 Tip 3 Circuit 2 Tip 4 Circuit 1 Ring 5 Circuit 1 Tip 6 Circuit 2...

Страница 215: ...l 4 61 5 3 GCD 2BRIA 2 Basic Rate Interface 5 3 1 Description This unit is an interface unit that accommodates an ISDN Basic Rate circuit The BRI blade provides Two GCD 2BRIA 2 Channel Circuits 2B D c...

Страница 216: ...sed This program will prevent new calls from being established on the blade but it will not terminate any existing calls With the maximum number of blades installed the following can be provided The 2...

Страница 217: ...de With normal operation the status LED flashes fast If trouble was found during the self diagnostics routine the status LED flashes slow Once connected the PKG LED will not be indicated for the statu...

Страница 218: ...ocation of the connectors on the GCD 2BRIA blade 5 3 5 Termination Switch Settings When the card is installed it may be necessary to change the termination switch settings These are found on the rear...

Страница 219: ...f the bus At the other end of the bus either the last socket contains terminators or the attached device provides the terminators The purpose of these terminators is not only to simulate an infinite l...

Страница 220: ...Issue 1 2 UNIVERGE SV9100 4 66 Installing the SV9100 Blades 5 4 PZ 2BRIA 2 Basic Rate Interface Daughter Board Figure 4 17 Installing the PZ 2BRIA Daughter Board...

Страница 221: ...rom the UNIVERGE SV9100s systems System programming must be used to block new calls on the blade This program will prevent new calls from being established on the blade but it will not terminate any e...

Страница 222: ...J 45 cable connector for S Bus and T Bus connections Refer to Figure 4 17 Installing the PZ 2BRIA Daughter Board on page 4 66 for an illustration showing the location of the connectors on the PZ 2BRIA...

Страница 223: ...e assumed to be at one end of the bus At the other end of the bus either the last socket contains terminators or the attached device provides the terminators The purpose of these terminators is not on...

Страница 224: ...line telephone interface functions such as Off Premise Extension The function type is assigned in programming for each port The circuit types however should be grouped together For example with three...

Страница 225: ...D 4DIOPB Blade on page 4 70 for the location of the LEDs on the blade Table 4 36 GCD 4DIOPB Maximum Upgrade Capacities 19 Chassis with CPU 19 Chassis without CPU 19 Chassis x4 Networked Chassis 5 6 23...

Страница 226: ...ned note that the blade consumes four 4DIOPU trunks or eight 8DIOPU trunks and extension ports when installed If OPX is not defined then only trunks ports are consumed Table 4 38 GCD 4DIOPB RJ 61 Cabl...

Страница 227: ...face PRI applications This blade has a single 30 channel 64Kb per second digital signal circuit configured for PRI Each blade connects to the network via an NTI Network Termination Each PRI blade prov...

Страница 228: ...32 ports in the system even if not all the ports are used otherwise the blade does not function The GCD PRTA requires one universal slot Table 4 39 GCD PRTA Maximum Upgrade Capacities provides the max...

Страница 229: ...plug to RJ 45 48C plug straight through or CAT5 cable to connect the T1 to the CSU Refer to Table 4 43 GCD PRTA RJ48C Connector Pin outs on page 4 79 With PRI Networking a cross over cable must be us...

Страница 230: ...information Table 4 40 GCD PRTA LED Indications LED Indication Operation Status Remarks Live LED Green Busy LED Red On ON System Initialising Flash 1s On The assignment of the unit is refused When you...

Страница 231: ...blink red green red green a Red LED will light AIS Alarm Indication Signal Blue Alarm Following an alarm blink red green red green a Red LED slowly flashes On and Off twice OOF Out Of Frame Red Alarm...

Страница 232: ...lustration showing the location of the connectors on the PRIU blade Note The order of priority is set up to alarm in the order LOS AIS OOF RAI Table 4 42 GCD PRTA RJ 45 Cable Connector Pin Outs RJ 45...

Страница 233: ...in outs Network Interface Pinout for the 8 Pin RJ48C Connector Terminal Interface Pinout for the 8 Pin RJ48C Connector Pin No Connection For connection to T1 network Use AT T Type ABAM cable or equiva...

Страница 234: ...blade This blade supports system connections to either 2 wire four lead tip ring or 4 wire eight lead tip ring tip 1 ring 1 E M signalling tie lines determined in Program 10 13 System programming is...

Страница 235: ...e Capacities 19 Chassis with CPU 19 Chassis without CPU 19 Chassis x4 Networked Chassis 5 6 23 50 Limitation depends on the connecting Router Multiplexer or Exchange If the UNIVERGE SV9100 is connecte...

Страница 236: ...Refer to Figure 4 22 GCD 4ODTB Blade on page 4 80 for an illustration showing the location of the connectors on the ODT blade Table 4 45 GCD 4ODTB LED Indications LED Indication Operation Status Remar...

Страница 237: ...Not Used 7 E Control signal from trunk 8 Not Used RJ 61 Cable Connector 4 Wire E M CN100 CN400 Pin No Connection Description 1 Not Used 2 M Control signal to trunk 3 R Voice signal to trunk 4 R1 Voice...

Страница 238: ...9100 Blades 5 7 5 Connections Figure 4 23 Voice Signal Connection for Type I And V on page 4 84 and Figure 4 24 Control Signal Connection on page 4 85 show the signaling methods for circuit types Figu...

Страница 239: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 85 Figure 4 24 Control Signal Connection...

Страница 240: ...and application software supporting a maximum of 16 ports A digital signal processor voice processing section handles the following functions p DTMF detection p DTMF generation p General tone detectio...

Страница 241: ...the CD VM00 refer to Figure 4 26 Install the CR 2032 Battery 3 To Install the SO DIMM memory on the CD VM00 blade insert the end with the brass connectors into the CN14 1 slot first 4 Push the other...

Страница 242: ...act Flash Drive 6 1 3 LED Indications 6 1 3 1 Active LED Green The Active LED is controlled by the DSP and indicates the board operational status o Off Power off o On Reset o Slow Flash Board is runni...

Страница 243: ...cation problem 6 1 3 4 CompactFlash Card Activity LED Red The CompactFlash Card Activity LED is controlled by the IDE controller and indicates read write activity on the CompactFlash card 6 1 4 Connec...

Страница 244: ...SV9100 4 90 Installing the SV9100 Blades 6 1 4 2 DB9 to 6 pin Modular RS 232 Adapter 6 1 4 3 RS 232 Serial Cable DTE Figure 4 29 GCD VM00 DB9 to 6 Pin Modular RS 232 Adapter Figure 4 30 GCD VM00 RS 23...

Страница 245: ...s a VGA display interface through a standard DB 15 connector 6 1 4 7 10 Base T 100 Base TX Ethernet Interface The APSU card provides a 10 Base T 100 Base TX Ethernet interface through an RJ 45 connect...

Страница 246: ...100 Blades The RJ 45 connector pin out is shown in Figure 4 32 Ethernet Connector Pin Out Figure 4 32 Ethernet Connector Pin Out View Pin No Signal Note 1 Tx PIN1 PIN8 2 Tx 10 Base T 100 Base TX port...

Страница 247: ...Application Packages Univerge Multimedia Conference Bridge and Interactive Voice Response Application This blade can be assigned as a CNF package to support Multimedia Conference Bridge or IVR package...

Страница 248: ...he IP Address of the CD PVAA Refer to Program 10 55 04 to configure the Subnet Mask of the CD PVAA Refer to Program 10 55 05 to configure the Gateway of the CD PVAA The CD PVAA blade is hot swappable...

Страница 249: ...d CompactFlash Card Activity LED is controlled by the IDE controller and indicates read write activity on the CompactFlash card 6 2 5 Connectors Ethernet Connector This connector is a single 10 100 Mb...

Страница 250: ...Base TX This blade is compatible in LAN applications using 10Mbps 100Mbps and 1000Mbs All ports automatically identify and switch 10 Base T 100 Base TX 1000 Base TX and Full Half Duplex Each GCD RGA b...

Страница 251: ...ding 1 1 NAT Port Forwarding Port Range Forwarding IP Based Access Restriction Access Policy p Services Management FTP SSH Telnet SMTP HTTP Custom Service p 4 Port Gigabit Ethernet Switch Switch Manag...

Страница 252: ...niversal slot the GCD RGA blade is installed in 3 Plug the GCD RGA blade into any universal slot 4 Refer to the UNIVERGE SV9100 RGA Multimedia Conference Solution Installation and Configuration Guide...

Страница 253: ...ange twice per second p Third party application running flash green five times per second Busy App LED Red Green The Busy App LED is controlled by the main processor and indicates the port status The...

Страница 254: ...erfaces The LAN ports are used for the local area network connections The WAN port is used for connecting to other networks or ISP refer to Table 4 48 GCD RGA Ethernet Connector Pin Outs Table 4 48 GC...

Страница 255: ...ll the user management and stacking is based on this setup This blade provides 8 Gigabit Ethernet 10 100 1000 Ports Per Port Status LED Indicating Link Speed and Activity 802 3af PoE on All Ports Prov...

Страница 256: ...et of three blades would appear to the UI as a 24 port switch instead of three 8 port switches The stacking will work by assigning a Master Management Card which provides all the GUI information for a...

Страница 257: ...e system until it receives an acknowledge message from the Main board The Main board receiving this broadcast message will acknowledge by sending port identification information to the Add on board 6...

Страница 258: ...units to form a 20 port switch is restricted to reside in a single system location The grouping is not allowed where the GSWU units are placed as part of the NetLink feature in the Univerge SV9100 sy...

Страница 259: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 105 NOTES...

Страница 260: ...Issue 1 2 UNIVERGE SV9100 4 106 Installing the SV9100 Blades...

Страница 261: ...features o 2 button terminal is non display o 6 button terminal equipped with LCD and full featured keypad o 12 button terminal is non display o Available in black DT 330 Value DTL 8LD DTL 12D DTL 24D...

Страница 262: ...pad o Available in black DT 430 Value DTZ 8LD DTZ 12D DTZ 24D o 8 button DESI Less LCD telephone o Also available are 12 24 32 button LCD telephones o Provides access to more sophisticated system feat...

Страница 263: ...s o Optional 60 button DSS Console provides 60 programmable keys and provides users a Busy Lamp Field BLF and 1 button access to extensions trunks and system features ITL 12PA o Power Save Adapter pro...

Страница 264: ...ated system features allowing room for growth o All DT 830s come with a standard backlit LCD display full duplex speakerphone capability module support for expansion and feature add on capability o Av...

Страница 265: ...T300 DT700 Terminal Adapter Unit ADA L APR L ILPA PSA L BCH L BHA L GBA L IP Terminals ITL 2E 1 BK TEL ITL 6DE 1 BK TEL ITL 8LDE 1 BK TEL ITL 8LD 1 BK WH TEL ITL 12D 1 BK WH TEL ITL 12CG 3 BK TEL 1 2...

Страница 266: ...ibility DT300 DT700 Continued Terminal Adapter Unit ADA L APR L ILPA PSA L BCH L BHA L GBA L Table 5 3 Terminal and Adapter Compatibility DT400 DT800 Terminal Adapter Unit ADA L APR L ILPAQ BHA Z BCA...

Страница 267: ...2E 1 BK TEL ITL 6DE 1 BK TEL ITL 8LDE 1 BK TEL ITL 8LD 1 BK WH TEL ITL 12D 1 BK WH TEL ITL 12CG 3 BK TEL ITL 12DG 3 BK TEL ITL 12PA 1 BK TEL ITL 24D 1 BK WH TEL ITL 32D 1 BK WH TEL ITL 320C 1 BK TEL D...

Страница 268: ...TZ 12D 3 BK WH TEL DTZ 24D 3 BK WH TEL DTZ 8LD 3 BK WH TEL IP Terminals DT800 ITZ 8LD 3 BK TEL ITZ 12D 3 BK WH TEL ITZ 24D 3 BK WH TEL ITZ 12CG 3 BK WH TEL ITZ 12DG 3 BK WH TEL ITZ 8LDG 3 BK WH TEL Op...

Страница 269: ...1 BK WH TEL DTL 12BT 1 BK TEL DTL 12PA 1 BK TEL DTL 24D 1 BK WH TEL DTL 32D 1 BK WH TEL Option Not Available Optional Available Table 5 7 Terminal and Ten Key Kit Compatibility DT400 DT800 Terminal Te...

Страница 270: ...8LD 3 BK TEL ITZ 12D 3 BK WH TEL ITZ 24D 3 BK WH TEL ITZ 12CG 3 BK WH TEL ITZ 12DG 3 BK WH TEL ITZ 8LDG 3 BK WH TEL Option Not Available Optional Available The Sticker Braille Z kit consists of stick...

Страница 271: ...K TEL ITL 6DE 1 BK TEL ITL 8LDE 1 BK TEL ITL 8LD 1 BK WH TEL ITL 12D 1 BK WH TEL ITL 12CG 3 BK TEL ITL 12DG 3 BK TEL ITL 12PA 1 BK TEL ITL 24D 1 BK WH TEL ITL 32D 1 BK WH TEL ITL 320C 1 BK TEL Digital...

Страница 272: ...minal and Optional Equipment Compatibility DT400 DT800 Terminal Equipment WM LQ 1 PANEL L Digital Terminals DT400 DTZ 2E 3 BK TEL DTZ 6DE 3 BK TEL DTZ 12D 3 BK WH TEL DTZ 24D 3 BK WH TEL DTZ 8LD 3 BK...

Страница 273: ...WH CONSOLE Q2 Option Not Available 4 Optional Available Q1 The WM L is required if the ADA L UNIT or APR L UNIT is installed on the telephone Q 2 DCZ 60 2 DSS Wall Mount Table 5 9 Terminal and Option...

Страница 274: ...LCD panels dial pads feature key kits handset cradles face plates and colored side panels can easily be snapped on and off to upgrade and customize as the customer desires 2 1 DT300 Series Digital Mul...

Страница 275: ...ine Terminal has six line keys with display and is available in black only The terminal features Non modular design Four step adjustable base Half duplex speaker phone Six line keys Red Green Four sof...

Страница 276: ...lack and white The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four soft keys Help Exit DESI less line key displays eight lines per p...

Страница 277: ...line keys and is available in black only The terminal features Keyset like Handset Eight Line Buttons Function Button Dial Button Display All Keyset Functions with Main Unit Cradle Charges Handset Ba...

Страница 278: ...d is available in both black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four soft keys Help Exit Three color LED 168 X...

Страница 279: ...able in black only The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four soft keys Help Exit Three color LED 168 X 58 dot matrix backl...

Страница 280: ...d is available in both black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four soft keys Help Exit Three color LED 168 X...

Страница 281: ...t and is available in both black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four soft keys Help Exit Three color LED 1...

Страница 282: ...Multiline Terminals 2 2 1 DTZ 2E 3 BK TEL This digital economy non display multiline terminal has two programmable line keys and is available in black only The terminal features Non modular design Fou...

Страница 283: ...my multiline terminal has six line keys with display and is available in black only The terminal features Non modular design Four step adjustable base Half duplex speaker phone Six line keys Red Green...

Страница 284: ...is available in both black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone 12 line keys Red Green Four Softkeys Help Exit Three color LED 168 X 58 do...

Страница 285: ...both black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone 24 line keys Red Green Four Softkeys Help Exit Three color LED 168 X 58 dot matrix LCD wit...

Страница 286: ...d white The terminal features Modular design Four step adjustable base Full duplex speaker phone Eight line keys Red Green Four Softkeys Help Exit DESI Less line key displays eight lines per page four...

Страница 287: ...adles face plates and colored side panels can easily be snapped on and off to upgrade and customize as the customer desires 3 1 DT700 IP MultilineTerminals 3 1 1 ITL 2E 1 BK TEL This IP economy non di...

Страница 288: ...display and is available in black only The terminal features Non modular design Four step adjustable base Remote login and maintenance Full duplex speaker phone Three color LED for message waiting 16...

Страница 289: ...nal features Non Modular design Four step adjustable base Full duplex speaker phone DESI less line key displays eight lines Function key changes from HOME to DESI Less screen Three colour LED for mess...

Страница 290: ...ur step adjustable base Full duplex speaker phone DESI less line key displays eight lines per page four pages of eight lines available using scroll key Protection button lock Seven color LED for incom...

Страница 291: ...s Modular design Four step adjustable base Full duplex speaker phone Protection button Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with cursor keys Menu Softkey operation provi...

Страница 292: ...SB 2 0 5V 500mA supply Modular design Four step adjustable base Full duplex speaker phone Protection button Seven colour LED for message waiting Menu Softkey operation provided on the LCD Backlit Numb...

Страница 293: ...upply Modular design Four step adjustable base Full duplex speaker phone Protection button Seven colour LED for message waiting Menu Softkey operation provided on the LCD Backlit Numbered Keypad for e...

Страница 294: ...atures Modular design Four step adjustable base Full duplex speaker phone Protection button Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with cursor keys Menu Softkey operation...

Страница 295: ...s Modular design Four step adjustable base Full duplex speaker phone Protection button Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with cursor keys Menu Softkey operation provi...

Страница 296: ...th black and white The terminal features Modular design Four step adjustable base Full duplex speaker phone Protection button Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with c...

Страница 297: ...l features Modular design Four step adjustable base Full duplex speaker phone Protection button Seven color LED for incoming calls Large touch color LCD Menu Softkey operation provided on the LCD Back...

Страница 298: ...both black and white The terminal features Modular design Four step adjustable base Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with cursor keys Backlit Numbered Keypad for ea...

Страница 299: ...terminal features Modular design Four step adjustable base Seven color LED for incoming calls Color LCD Backlit Numbered Keypad for easy viewing 10 Base T 100 Base TX 1000 BASE T network interface 12...

Страница 300: ...and white The terminal features Modular design Four step adjustable base Seven color LED for incoming calls Monochrome LCD Backlit Numbered Keypad for easy viewing 10 Base T 100 Base TX 1000 BASE T n...

Страница 301: ...eatures Modular design Four step adjustable base Seven color LED for incoming calls 224 X 96 full dot gray scale LCD with cursor keys Backlit Numbered Keypad for easy viewing 10 Base T 100 Base TX net...

Страница 302: ...r design Four step adjustable base Seven color LED for incoming calls Two 224 X 96 full dot gray scale LCDs with cursor keys DESI Less line key displays eight lines per page four pages of eight lines...

Страница 303: ...1 1 1 Handset Connection DT300 1 Install the modular plug attached to the curl cord of the handset into the handset connector at the back of terminal Push until it snaps into place 2 Lead the Handset...

Страница 304: ...ne cord to the multiline terminal using the steps shown below 4 1 2 1 Line Cord Connection DT300 1 Install the modular plug of the Line Cord into the Line Connector at the back of terminal Push until...

Страница 305: ...legs Refer to Figure 5 34 Line Cord Groove Back of Terminal DT300 4 1 2 2 Line Cord Connection DT400 4 Install the modular plug of the Line Cord into the Line Connector at the back of terminal Push u...

Страница 306: ...he groove Refer to Figure 5 36 Line Cord Groove DT400 6 Turn the terminal over and place it so the Line Cord can be passed through the groove between the tilt legs Refer to Figure 5 34 Line Cord Groov...

Страница 307: ...AC 3R AC Adapter input Jack in the terminal base unit and plug the wall plug of the AC Adapter in a standard 230 Vac wall outlet In Line Power PoE Power over Ethernet In Line Power sometimes called P...

Страница 308: ...00 series Multiline Terminals Refer to Figure 5 37 IP Terminal Connector Locations 1 Connect the LAN Network 10Base T 100Base TX cable to the LAN connector 2 The IP terminal has a switching HUB to con...

Страница 309: ...CD on the Multiline Terminal DT Series display Multiline Terminals have an adjustable Liquid Crystal Display LCD The LCD can be adjusted by pulling up or pushing down as desired Figure 5 38 Typical Ne...

Страница 310: ...Turn multiline terminal upside down Only one 12LK L KIT can be attached to the DTL ITL multiline terminal 2 Pry the right side panel from the multiline terminal 3 From the lower left or right corner p...

Страница 311: ...d remove the DESI sheet 5 Press the right end of the Line Key placeholder and lift to remove refer to Figure 5 43 Removing the Line Key Placeholder on page 5 52 Figure 5 41 Removing the Line Key Panel...

Страница 312: ...nstalling DT Series Digital and IP Multiline Terminals 6 Install the 12LK L KIT and press down until click is heard Figure 5 43 Removing the Line Key Placeholder Figure 5 44 Installing the 12LK L KIT...

Страница 313: ...t 8 Install the supplied Line Key Panel refer to Figure 5 46 Installing the Line Key Panel 9 Install the side panel 10 Connect the line cord LAN cable and the AC DC adapter to the DTL ITL multiline te...

Страница 314: ...below for the type of line key module installed 4 Save to memory by pressing line key 2 8 14 or 20 The display changes back to the Service Class R W mode and the MW LED will be lit Red 5 Press Exit t...

Страница 315: ...ed 9 Press Soft Key 4 for OK to complete Table 5 11 Keypad Kit Type Keypad Kit Entry Description Kit1 Type A Japan with cursor key Kit2 Type A US with cursor key Kit3 Type B US with cursor key Kit4 Ki...

Страница 316: ...the directory card Attach the directory card to the directory card holder as illustrated in Figure 5 47 Attaching Directory Card to Directory Card Holder Note that the open end slides into the direct...

Страница 317: ...ed on a multiline terminal replacing the Standard Numbered Keypad Standard Numbered Keypad The standard keypad in black or white is commonly delivered with the UNIVERGE SV9100 terminal refer to Figure...

Страница 318: ...iline Terminals BS Retro L KIT The optional Retro keypad in black or white is compatible with the Dterm Series i telephone allowing the terminal to be used with the IPK II IPC 500 and IPS multiline te...

Страница 319: ...to remove the existing button See Figure 5 52 Removing Numbered Keypad from DT300 DT700 Series Terminal Figure 5 51 Remove Plastic Panels Figure 5 52 Removing Numbered Keypad from DT300 DT700 Series...

Страница 320: ...on the keypad to snap it into place See Figure 5 53 Install New Numbered Keypad into DT300 DT700 Series Terminal 4 Insert the DESI printer sheet and plastic panels on the multiline terminal Refer to...

Страница 321: ...ss R W mode and the MW LED will be lit Red 5 Press Exit to return the telephone to the idle condition 4 7 3 Configuring the IP Telephone for the Numbered Keypad 1 Enter the terminal s program mode by...

Страница 322: ...ct the type of line key kit being used by pressing the Up Down key By default the correct line key kit for the keypad kit selected above will be highlighted Table 5 14 Keypad Kit Type Keypad Kit Entry...

Страница 323: ...Series Multiline terminals can be adjusted by moving the legs attached to the bottom of the terminal 1 Turn telephone over button side down 2 Adjust legs to desired height refer to Figure 5 55 Adjust...

Страница 324: ...or by cutting the sticker from the sheet and placing the sticker in the Directory Card holder Sticker 3 12 button and 24 button telephones The LN LND sticker is applied directly to the button by peel...

Страница 325: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 5 65 Figure 5 57 Sticker Braille L KIT Sheet 2...

Страница 326: ...button side down 2 Adjust legs to desired height refer to Figure 5 55 Adjust Height of DT300 DT700 Series Terminal 3 Turn telephone over button side up 4 11 Removing or Installing the Tilt Legs on the...

Страница 327: ...downward refer to Figure 5 60 Remove Tilt Legs from Multiline Terminal 4 Lift and remove the Tilt Legs 4 11 2 Install Tilt Legs 1 Place the telephone on a flat surface button side down 2 Lay the adju...

Страница 328: ...rminal 3 Push the Tilt Legs upward until they snap into place 4 Lift both ends of Tilt Legs until they come together refer to Figure 5 62 Connecting the Tilt Legs on page 5 68 5 Snap legs together and...

Страница 329: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 5 69 5 63 Adjust Height of Multline Terminal Figure 5 63 Adjust Height of Multline Terminal...

Страница 330: ...unit must be used if adapters are installed on the Multiline Terminal 4 12 1 Wall Mounting a Multiline Terminal using the Base Plate 4 12 1 1 Adjusting the Hanger Hook 1 Remove the hook from the unit...

Страница 331: ...Cord 2 Ensure the Tilt Legs are in the flat unused position 3 Plug the line cord into the Multiline Terminal as illustrated in Figure 5 67 Plugging in Line Cord 4 Align the two holes on the back of t...

Страница 332: ...are line cord behind the Multiline Terminal 4 12 1 3 Removing the Multiline Terminal from the Wall Mounted Base Plate To remove the Multiline Terminal push up on the telephone until it comes loose Fig...

Страница 333: ...he base and hang the cover over the screws on the switch box as illustrated in Figure 5 70 Wall Mounting Base on Switch Box 2 Hang the Multiline Terminal on the base Because of strength variation in s...

Страница 334: ...nals Sophisticated ITL 320C 1 Value ITL 8LD 1 ITL 12D 1 ITL 12CG 3 ITL 12DG 3 ITL 24D 1 ITL 32D 1 Economy ITL 2E 1 ITL 6DE 1 ITL 8LDE 1 Value DTL 8LD 1 DTL 12D 1 DTL 24D 1 DTL 32D 1 Economy DTL 2E 1 D...

Страница 335: ...ITL 24D 1 ITL 32D 1 Economy ITL 2E 1 ITL 6DE 1 ITL 8LDE 1 Value DTL 8LD 1 DTL 12D 1 DTL 24D 1 DTL 32D 1 Economy DTL 2E 1 DTL 6DE 1 Table 5 17 Connectivity of Options DT400 DT800 Terminal Options IP T...

Страница 336: ...terminal Supports Red and Green LED colors 5 2 1 1 Installing the 8LK L UNIT 1 Remove both plastic panels from the front of the multiline terminal 2 Turn multiline terminal upside down Only one 8LK L...

Страница 337: ...uttons side up position 5 Fit the projections on the side of the 8LK L UNIT into the guide holes on the side of the multiline terminal 6 Secure the 8LK L UNIT with the two screws provided 7 Turn the m...

Страница 338: ...10 Attach the side panel to the side of the 8LK L UNIT 11 Return the multiline terminal to the buttons side up position 12 Complete the installation by reattaching both plastic panels to the front of...

Страница 339: ...the DTL multiline terminal 2 Pry the side panel from the multiline terminal Figure 5 76 8LKD LD L UNIT Figure 5 77 Remove Side Panel from Multiline Terminal To prevent possible damage to the 8LKD LD L...

Страница 340: ...tons side up position 5 Remove the soft keys and line key kit from the telephone 6 Gently lift the small black bar on the ribbon cable connector refer to Figure 5 78 Ribbon Cable Connector 7 Plug ribb...

Страница 341: ...the 8LKD LD L UNIT into the guide holes on top of the multiline terminal 10 Slide the 8LKD LD L UNIT toward the keypad buttons until snug refer to Figure 5 80 8LKD LD L UNIT Installed Figure 5 79 Rib...

Страница 342: ...er to Figure 5 87 Install Screw on page 5 86 14 Return the multiline terminal to the buttons side up position 15 Connect the line cord LAN cable and the AC DC adapter to the DTL multiline terminal 5 2...

Страница 343: ...the ITL multiline terminal 2 Pry the side panel from the multiline terminal Figure 5 82 8LKI LD L UNIT Figure 5 83 Remove Side Panel from Multiline Terminal To prevent possible damage to the 8LKI LD L...

Страница 344: ...l to the buttons side up position 5 Remove the soft keys and line key kit from the telephone 6 Gently lift the small black bar to open the ribbon cable connector 7 Plug ribbon cable on back of 8LKI LD...

Страница 345: ...to the guide holes on top of the multiline terminal refer to Figure 5 85 Ribbon Cable Installed 10 Slide the 8LKI LD L UNIT toward the keypad buttons until snug refer to Figure 5 86 8LKI LD L UNIT Ins...

Страница 346: ...dant Console has 60 programmable line keys and is available in black or white The unit features 60 programmable Direct Station Selection DSS keys refer to system user guides Supported on ITL ITZ or DT...

Страница 347: ...to 32 different extensions with DSS Consoles can be set up A single extension can have up to four 60 button DSS Consoles 32 is the maximum allowed per system Each DSS console fitted to a TDM port wil...

Страница 348: ...tiline terminal 4 Turn the multiline terminal button side up 5 Fit the projections of the supplied bracket into the side of the multiline terminal 6 Attach the bracket with three supplied screws Figur...

Страница 349: ...00 DT800 only 8 Using the guides slide the DCL 60 1 onto the installed bracket refer to Figure 5 91 Press Serial Cable into Groove 9 Secure the DCL 60 1 DCZ 60 2 CONSOLE to the bracket with the two sc...

Страница 350: ...0 only 12 Set the height of the tilt leg on the multiline terminal to the desired height 13 Set the height of the tilt leg on the DCL 60 1 DCZ 60 2 CONSOLE to match the tilt leg on the multiline termi...

Страница 351: ...th plastic panels to the front of the multiline terminal 5 2 5 LCD BL L BK UNIT LCD BL L WH UNIT The LCD BL L UNIT is an optional LCD unit for modular terminals and supports the backlit LCD feature DT...

Страница 352: ...DT400 Series only 5 2 7 PANEL L UNIT Optional plastic color side panels that allow users to customize the ITL DTL terminals The following colors are available for the Base all VLCD Value LCD and SLCD...

Страница 353: ...ional adapters are used the multiline terminal must be installed on the wall using the WM L UNIT 1 Plug line cord in the wall receptacle Leave about eight inches of cord and bundle the rest 2 Feed the...

Страница 354: ...Issue 1 2 UNIVERGE SV9100 5 94 Installing DT Series Digital and IP Multiline Terminals refer to Figure 5 100 Cutouts for WM L UNIT Figure 5 100 Cutouts for WM L UNIT Cutouts Cutouts...

Страница 355: ...o place refer to Figure 5 101 WM L UNIT Installed 5 2 9 Release the WM L UNIT 1 To release the telephone from the WM L UNIT press the release button and push the telephone up refer to Figure 5 102 WM...

Страница 356: ...used the multiline terminal must be installed on the wall plate using the WM L UNIT 1 Plug line cord in the wall plate receptacle Leave about eight inches of cord and bundle the rest 2 Feed the line...

Страница 357: ...Issue 1 2 System Hardware Manual 5 97 5 Push up on the WM L UNIT until it snaps into place refer to Figure 5 105 WM L UNIT Installed Figure 5 104 Cutouts for WM L UNIT Figure 5 105 WM L UNIT Installed...

Страница 358: ...nt Multiline Terminal Wall on Wall Plate Because of strength variation in switch boxes this method is not recommended 7 Push excess line cord behind the Multiline Terminal 5 2 11 Removing the Multilin...

Страница 359: ...s to the bottom of the terminal 5 2 12 1 Mount DCL 60 1 DCZ 60 2 CONSOLE on Wall using DSS WM L UNIT Use the template shown in Figure 5 108 Wall Mount Spacing Guide DSS WM L UNIT for required spacing...

Страница 360: ...UNIT 1 Locate the screw holes on the base and hang the cover over the screws on the wall plate as illustrated in Figure 5 110 Attach DSS WM L UNIT to Wall Plate Because of variation in wall plates thi...

Страница 361: ...of cord and bundle the rest 3 Plug the opposite end of the line cord into the DCL 60 1 DCZ 60 2 CONSOLE as illustrated in Figure 5 112 Plugging Cable into DCL 60 1 DCZ 60 2 CONSOLE Figure 5 111 Plug C...

Страница 362: ...handsets are also an ideal solution to filter unwanted audio transmissions from environments with ambient background noise 6 2 ITL DTL PTT Handset The Push to Talk PTT handset has a single pole singl...

Страница 363: ...stress associated with holding the handset between the ear and and shoulder The user immediately hears a dial tone upon taking the handset off hook eliminating the need to click on off hook icons in a...

Страница 364: ...g The UTR 1 1 USB handset can be mounted on the wall using a wall plate or two screws Align the two holes on the back of the UTR 1 1 and slide down onto the wall plate or screws Because of strength va...

Страница 365: ...ch device simultaneously This maximum can be affected by the installation environment The BCH and a Bluetooth headset BTH cannot be used at the same time When using a Bluetooth headset in place of the...

Страница 366: ...installed near a metal concrete wall or any other structure that could affect radio transmission a communication failure might occur Keep the Bluetooth cradle at least 9 8 feet 3 meters apart from an...

Страница 367: ...107 7 3 Controls and Indicators Controls and indicators can be found in Figure 5 118 Bluetooth Cradle Controls and Indicators or Figure 5 119 Bluetooth Handset Controls and Indicators on page 5 108 Fi...

Страница 368: ...Issue 1 2 UNIVERGE SV9100 5 108 Installing DT Series Digital and IP Multiline Terminals Figure 5 119 Bluetooth Handset Controls and Indicators...

Страница 369: ...ne cord and handset cord from the multiline terminal Only one BCH L BK UNIT can be attached to the DTL multiline terminal 3 Lower the tilt leg to the first position refer to Figure 5 120 Separate Tilt...

Страница 370: ...rd from terminal body Leave cord connected to the cradle unit 9 Push the latch to the right to unlock the cradle unit Then push the cradle unit forward to separate it from the terminal body see Figure...

Страница 371: ...tooth Cradle into the guide holes on the side of the terminal and pull toward you Figure 5 123 Attach Bluetooth Cradle to the Multiline Terminal until the unit snaps into place 12 Attach the side pane...

Страница 372: ...bottom of the multiline terminal 15 Insert the lower claws of the Bottom Unit see Figure 5 126 Installing the Bottom Unit into precut holes on the multiline terminal 16 Align connector on inside of bo...

Страница 373: ...nnecting cable and close the cover 18 Cut or trim the supplied coupled device for the tilt legs handset option 19 Insert the stopper coupled device into the right and left tilt legs see Figure 5 128 I...

Страница 374: ...numbered keypad in the up position 24 Connect the Line cord and the AC adapter 25 Place the Bluetooth handset in the cradle Before you use the handset for the first time or reuse the handset after it...

Страница 375: ...can withstand the weight of the telephone and the load from pulling the telephone during operation 1 Attach two wood screws to the wall Keep a clearance of about 0 08 2mm between each wood screw and...

Страница 376: ...move the Bluetooth hanger from the cradle With a screwdriver pry from the bottom and lift the handset hanger from the cradle 3 Rotate the hanger top to bottom Slide it downward in the hollow until it...

Страница 377: ...er the tilt leg to the first position refer to Figure 5 120 Separate Tilt Leg from Leg Support 6 Hook the wall mount holes C and D on the back of the terminal on wood screws c and d installed Figure 5...

Страница 378: ...ow the handset is used If the battery voltage diminishes quickly after the battery has been charged for a long time replace with a new Li ion battery 1 Remove cover from back of handset 2 Remove exist...

Страница 379: ...rminal upside down 2 Unplug the line cord and handset cord from the multiline terminal Only one BHA L UNIT can be attached to the DTL multiline terminal 3 Lower the tilt leg to the first position refe...

Страница 380: ...L UNIT into precut holes on the multiline terminal 6 Align connector on inside of BHA L UNIT and push down until unit snaps into place 7 Set tilt legs to desired position 8 Return the multiline termin...

Страница 381: ...L UNIT is connected to an Aspire X Press menu keys 5 Optional Devices 1 Bluetooth If the BHA L UNIT is connected to a PBX other than Aspire X Press menu keys 3 Setup 5 Optional Devices 1 Bluetooth 8 1...

Страница 382: ...elect the device in the Delete screen 8 1 2 6 Visibility Setting Set whether to make information about the BHA L UNIT visible to other Bluetooth devices default 1 Disable After pairing a Bluetooth dev...

Страница 383: ...1 2 7 BT Information You can view the following kinds of information about the BHA L UNIT Firmware and hardware versions Bluetooth module information and standard Installed profile versions Device add...

Страница 384: ...ne Telephones and other similar devices from an ESI channel This adapter can be connected to any ESI port 1 Connect one end of the RJ 11 to the ESI port on the chassis and one end to the ESI jack on t...

Страница 385: ...the SLT Adapter 3 Lift the cover off the adapter Figure 5 147 Connecting the SLT Adapter Figure 5 148 Removing the Cover 3 4 Modular Terminal Connections Single Line Telephone Connections SLTII 1 U AD...

Страница 386: ...ls 4 Using the two screws provided with the SLT Adapter attach the back cover to the desired location 5 Replace the front cover and the two screws removed in Step 2 6 Plug the two modular line cords b...

Страница 387: ...lephone that is adapted for digital NEC PBX Private Branch Exchange It is designed for use in the office environment Figure 5 150 Dterm Cordless DECT DTL 8R 1 m A Handset and wired phone cannot be use...

Страница 388: ...ERGE SV9100 complies with FCC and IC part 15 General Base Unit Figure 5 151 System Overview RoHs Yes Frequency 1 9G 1880 1900 MHz Audio Process Digital ADPCM Operating Temperature 0 50 C 32 F to 122 F...

Страница 389: ...e is corrosive and can cause damage to the eyes or skin It may be toxic if swallowed q Exercise care in handling the battery in order not to short the battery with conducting materials such as rings b...

Страница 390: ...d liquid cleaners or aerosol cleaners Use a dry cloth for cleaning q Do not use this product near water for example near a sink or in a wet area q Do not place this product on an unstable cart stand o...

Страница 391: ...ity or the leak q To reduce the risk of fire or injury to persons by the battery read and follow these instructions m Use only the appropriate type and size battery pack specified in the manual m Exer...

Страница 392: ...Digital and IP Multiline Terminals Changes or modifications to this product not expressly approved by NEC Unified Solutions or operation of this product in any way other than as detailed by this manu...

Страница 393: ...to see what appliances may be causing the problem In addition we recommend that the base not be plugged into a circuit that also powers a major appliance because of the potential of interference In th...

Страница 394: ...ar a standard 230 Vac outlet and telephone line jack The base unit can also be mounted on a standard wall plate using the wall mount adapter Keep the base unit and handset away from sources of electri...

Страница 395: ...he Line In on the Dterm Cordless DECT 2 Connect a qualified NEC digital multiline terminal to the Dterm Cordless DECT Figure 5 152 Connecting Telephone Cords to the Telephone Jack Figure 5 153 Connect...

Страница 396: ...he AC adapter furnished with this telephone may be equipped with a polarized line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way If you are una...

Страница 397: ...ch the wall mount stand to the base unit 1 Slide the wall mount stand into the notches at the top of the base unit Rotate the wall mount stand down and snap it into place 2 Plug the AC adapter into th...

Страница 398: ...of the short telephone cord locally supplied in the LINE jack on the base unit Plug one end of the NEC digital multiline terminal into the PHONE jack Place the telephone cords inside the molded channe...

Страница 399: ...e unit on the posts of the wall plate and push down until it is firmly seated Because of variation in wall plates this method is not recommended 7 Plug the AC adapter into a standard 230 Vac wall outl...

Страница 400: ...ight of the base unit m Use 10 screws with anchoring devices suitable for the wall material where the base unit will be placed To mount the telephone 1 Insert two mounting screws 3 15 16 inches apart...

Страница 401: ...of the short telephone cord into a telephone wall jack 7 Plug the AC adapter into a standard 230 Vac wall outlet Refer to Figure 5 159 Plugging the AC Adapter into the AC Wall Outlet on page 5 139 Do...

Страница 402: ...g screws into the wall m Make sure the wall material can support the weight of the charging unit m Use 10 screws with anchoring devices suitable for the wall material where the charging unit will be p...

Страница 403: ...er to Figure 5 165 Placing the Charging Unit on the Wall 10 12 Attaching and Removing the Belt Clip A belt clip can be used to attach the handset to a belt or pocket for convenient portability 1 Slide...

Страница 404: ...time 10 13 Installing the Handset Battery Pack Before installing batteries refer to Dterm Cordless DECT Owner s Manual Specifications and Battery Safety It is important to follow safety regulations w...

Страница 405: ...handset 10 14 Charging Batteries The rechargeable battery pack must be fully charged before using the Dterm Cordless DECT for the first time Charge the battery pack without interruption for five to e...

Страница 406: ...d powering on the handset 11 1 Connecting the Base Station If your network connection does not provide Power Over Ethernet you will need to order a base station AC adapter and a standard Ethernet to P...

Страница 407: ...and connects to the network the Yellow LED light remains steady on refer to Table 5 19 Base Station LED States and Meanings on page 5 147 Table 5 19 Base Station LED States and Meanings LED Status St...

Страница 408: ...ion Dimensions 2 Insert the appropriate anchors for the wall material 3 Insert the mounting screws into the anchors leaving about 1 4 inch of space between the screw head and the wall 4 Connect the Et...

Страница 409: ...ual 5 149 11 3 Handset and Charger Figure 5 174 ML440 Handset Front View on page 5 149 provides a front view of the handset Figure 5 175 ML440 Handset Charger on page 5 150 provides a to view of the c...

Страница 410: ...rging the Battery 1 Install the handset battery as shown Figure 5 176 ML440 Handset Battery Installation Remove the battery cover from the back of the handset Insert the bottom of the battery into the...

Страница 411: ...et 4 Place the spare battery if available in the back section of the charger the BATTERY STATUS LED should turn on Pull the battery latch back slightly to fit the battery in the slot Figure 5 177 ML44...

Страница 412: ...Issue 1 2 UNIVERGE SV9100 5 152 Installing DT Series Digital and IP Multiline Terminals...

Страница 413: ...maximum per system External Speaker eight maximum with PGD 2 U10 ADPs with amplifier one on the GCD CP10 no amplifier External Music Source external MOH 96 maximum per system External Recording Syste...

Страница 414: ...ble connections should be made first For the module to ID correctly after setting the jumpers set the circuit type to 0 for the module port in Program 10 03 01 prior to connecting the line cord to the...

Страница 415: ...2 Using a screwdriver break out the plastic piece covering the cable hole 3 Set the S3 S6 jumpers to the proper settings for the function to be used refer to Table 6 2 PGD 2 U10 ADP S3 S6 Jumper Sett...

Страница 416: ...l Paging Speaker On when in use Short Open External Ringer On when in use Short Short External Music on Hold Recording System On steady Channel 2 S5 S6 Function LED Indication Open Open Door Box On wh...

Страница 417: ...ximately 1 4 8 mm of bare wire is exposed 5 Insert the cable into the proper CN4 or CN5 location while holding down the lock button holding down this lock button is easiest with a flat head screwdrive...

Страница 418: ...Issue 1 2 UNIVERGE SV9100 6 6 Installing SV9100 Optional Equipment Figure 6 5 PGD 2 U10 ADP Connection Diagram...

Страница 419: ...Replace the cover and tighten the screw to hold the cover in place 8 If required for the function being used insert the RCA connectors into the CN2 Channel 1 and CN3 Channel 2 connectors on the back...

Страница 420: ...sed leads to the jack 11 Install bridging clips as required For the module to ID correctly set the circuit type to 0 for the port in Program 10 03 01 prior to connecting the line cord 12 Plug a modula...

Страница 421: ...r location 14 The back of the PGD 2 U10 ADP has two key hole type openings Place the PGD 2 U10 ADP over the two screws and slide it down or over depending on the positioning to lock it in place Figure...

Страница 422: ...eysets If an extension user activates it BGM plays whenever the user s extension is idle 1 Connecting to the GCD CP10 Connect an RCA line from the CN8 or CN9 connector on the GCD CP10 to the appropria...

Страница 423: ...r the Door Box used The relays on the PGD 2 U10 ADPs are numbered 5 8 The relay closes when the Door Box external page zone is called The maximum applied voltage is 24vDC at 0 5A for each contact 1 Ma...

Страница 424: ...in the proper polarity The maximum distance between the PGDAD and the DX4NA door box is approx 70m for 0 4mm cable and approx 110m for 0 5mm cable 10 Replace the front half of the Door Box and reattac...

Страница 425: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 6 13 Figure 6 11 Setting the PGD 2 U10 ADP for a Door Box...

Страница 426: ...Issue 1 2 UNIVERGE SV9100 6 14 Installing SV9100 Optional Equipment Figure 6 12 Installing a Door Box...

Страница 427: ...e GCD CP10 cannot be used for talkback 5 2 Installing an External Page System 1 Connecting to the GCD CP10 Connect an RCA line from the CN8 or CN9 connector on the GCD CP10 to the appropriate location...

Страница 428: ...erminate the unused leads to the jack 5 Install bridging clips as required 6 Plug a modular line cord from the mod jack to the CN1 connector on the PGD 2 U10 ADP 7 Connect the two conductor station ca...

Страница 429: ...ox external page circuit provides a dry relay contact Program Note Program 10 21 01 sets the relay switch on the GCD CP10 If set to 2 External Speaker service code 703 1 pages and the relay closes The...

Страница 430: ...e PGD 2 U10 ADP Make sure the jumper in the PGD 2 U10 ADP for the channel is set correctly Refer to Figure 6 4 PGD 2 U10 ADP Jumper Settings on page 6 4 2 If a line cord was not previously connected t...

Страница 431: ...to the CTL control relay jack By using Department Calling you can arrange multiple tape recorders into a pool When an extension user dials the Department Group pilot number they reach the first avail...

Страница 432: ...For each module run one pair 24 AWG station cable from the cross connect block to a modular jack Ground the unused pair 4 Terminate the extension leads to GRN RED of the modular jack Terminate the un...

Страница 433: ...ircuit had previously been defined for another type of circuit unplug the PGD 2 U10 ADP and plug it back in to reset the circuit type 10 05 01 General Purpose Relay Setup Define which relay circuits 5...

Страница 434: ...07 01 Conversation Record Circuits Assign the number of conversation record circuits 14 09 01 ACI Conversation Recording Destination for Trunks ACI Recording Destination Extension Number Use this opti...

Страница 435: ...grams 14 09 and 15 12 the destination in Program 15 12 will be followed 15 12 02 Conversation Recording Destination for Extensions ACI Automatic Recording for Incoming Call Determine whether an extens...

Страница 436: ...is placed on Hold the MOH relay is activated This allows an external relay sensor power supply to turn on the MOH source This arrangement allows the MOH source e g a tape deck to run only when a call...

Страница 437: ...ED of the modular jack Terminate the unused leads to the jack 5 Install bridging clips as required 6 Plug a modular line cord from the mod jack to the CN1 connector on the PGD 2 U10 ADP 7 Connect an R...

Страница 438: ...Issue 1 2 UNIVERGE SV9100 6 26 Installing SV9100 Optional Equipment Figure 6 17 PGD 2 U10 ADP Connections...

Страница 439: ...2 Configure PRG12 01 03 to define the Night Mode the system will use when the switch is closed 3 Configure PRG12 01 04 to define the Sensor Circuit to be used as the switching relay SECTION 10 TELEPH...

Страница 440: ...h at the lower right corner of the telephone to lift the faceplate up Each corner has a plastic locking pin which releases as the faceplate is lifted up 10 1 2 Replacing the Faceplate 1 Place the face...

Страница 441: ...t be unplugged from the system External power is not required for the adapter Telephones with any adapters installed require an optional wall mount unit WM L to be wall mounted The bracket does not ac...

Страница 442: ...enter feed can be used This adapter cannot be used with the H 323 telephones When center feed is used unplug the adapter from the ethernet switch before changing the SW1 setting on the back of the ada...

Страница 443: ...or IP adapter to the correct position Figure 6 21 In Line Power Adapter Switch Settings Center Feed Hub System SW1 Setting IEEE802 3af STD System 1 Cisco Discovery Protocol System 1 NEC BlueFire 200...

Страница 444: ...pter can be positioned either closer to the keyset or switch it does not matter 4 Connect a cross over LAN cable to the LAN connector on the ILPA R adapter Plug the opposite end into the switch which...

Страница 445: ...the keyset should be unplugged from the system Be sure the connected audio device provides a standard AUX level input The use of monitoring recording or listening devices to eavesdrop monitor retriev...

Страница 446: ...recorder or to enable disable the record start warning tones refer to Table 6 3 ADA L Unit Switch Settings Figure 6 23 ADA L UNIT Table 6 3 ADA L Unit Switch Settings Switch Description Settings SW1 S...

Страница 447: ...Leg from Leg Support Dip Switches DSW DSW 1 Output Hook Signal to External Device On Output Off No Output Default DSW 2 Record Confirmation Tone On Tone On Off Tone Off Default DSW 3 and DSW 4 Use T1...

Страница 448: ...terface refer to Figure 6 25 Bottom Option Interface Knockout 7 Using the exposed Bottom Option Interface as a guide install the ADA L UNIT in the bottom of the DTL ITL multiline terminal Push down un...

Страница 449: ...t the the ADA L Unit Out jack to the cassette recorder MIC jack Refer to Figure 6 27 ADA L OUT Jack Connection Figure 6 27 ADA L OUT Jack Connection The mini plug connection cord should not use an att...

Страница 450: ...e extension number for the analog device which allows both devices to be used at the same time this can be removed in system programming if you wish One terminal can have an APR L UNIT adapter The max...

Страница 451: ...ion of the switches The dip switches DSW allow a technician to configure the unit for specific settings Set the dip switches on the APR adapter to the required position 1 Leave the SW1 switch at its f...

Страница 452: ...ion refer to Figure 6 30 Separate Tilt Leg from Leg Support 4 Push the two stopper tabs through the slots to separate the tilt leg from the leg support 5 Lay the tilt leg and the leg support flat to e...

Страница 453: ...o be recognized correctly before plugging in the keyset make sure the extension number to be used for the adapter is undefined in Program 10 03 01 10 Plug the line cord back into the keyset 11 Using t...

Страница 454: ...use the same extension number as the telephone to which it is attached remove the terminal type in this option With this setup when the analog device is in use it busies out the terminal as there is n...

Страница 455: ...When power is restored the IP telephone restarts and connects to the network unless a conversation is in progress on PSTN The PSTN call must be completed by going on hook before the connection to the...

Страница 456: ...ndset cord from the keyset Only one PSA L UNIT can be attached to the DTL ITL multiline terminal 3 Lower the tilt leg to the first position refer to Figure 6 36 Separate Tilt Leg from Leg Support on p...

Страница 457: ...e tilt leg and the leg support flat 6 Press the two tabs locking the legs to the multiline terminal and pull the legs toward you lifting to remove 7 Disconnect serial connection cord from terminal bod...

Страница 458: ...cradle unit forward to separate from the terminal body 9 Fit the projections on the side of the PSA L UNIT into the guide holes on the side of the terminal and pull toward you until the PSA L UNIT sna...

Страница 459: ...o the Multiline Terminal on page 6 46 from the PSA L UNIT to the terminal body 12 Open the Dip Switch Cover refer to Figure 6 35 PSA L UNIT Connections on page 6 44 Set the dip switch on the PSA L ada...

Страница 460: ...page 6 44 16 Reinstall the legs pushing upwards until both locks snap into place 17 Return tilt leg to desired position 18 Return the multiline terminal to the numbered keypad in the up position 19 C...

Страница 461: ...he numbered keypad panel 22 Install the new keypad panel supplied with the PSA L UNIT 23 Reinstall both plastic panels to the front of the multiline terminal refer to Figure 6 46 Install Plastic Panel...

Страница 462: ...Adapter 1 Placing Calls When the PSTN line is activated either manually by the switch or due to a power failure use the dial pad buttons 0 9 to place an outside call Use the Vol or to increase or decr...

Страница 463: ...calls no other terminal functions are available 4 When Power is Restored The IP keyset restarts and reconnects to the network LAN However if you are on a PSTN call when the power is restored your conv...

Страница 464: ...and handset cord from the multiline terminal Only one GBA L UNIT can be attached to the DTL ITL multiline terminal 3 Lower the tilt leg to the first position refer to Figure 6 48 Separate Tilt Leg fro...

Страница 465: ...rate the tilt leg from the leg support 5 Lay the tilt leg and the leg support flat 6 Press the two tabs locking the legs to the multiline terminal and pull the legs toward you lifting to remove Figure...

Страница 466: ...and gently press the cable into the grooved cutout refer to Figure 6 50 Attach the LAN Cable 8 Plug in the DC power cable and gently press the cable into the grooved cutout refer to Figure 6 51 Attac...

Страница 467: ...and bracket then align with tab holes refer to Figure 6 52 Align Bracket with Terminal 10 Pass the LAN and DC power cables through the bracket refer to Figure 6 53 Pass Cabling Through Bracket Figure...

Страница 468: ...racket forward until a click is heard refer to Figure 6 54 Secure Bracket to Terminal 12 Secure base of GBA L UNIT to bracket assembly refer to Figure 6 55 Secure GBA L UNIT Base to Bracket Assembly F...

Страница 469: ...l 6 57 13 Install the NEC provided Cat 5 Ethernet cable refer to Figure 6 56 IP Phone X Connection 14 Install the NEC provided Cat 5 Ethernet cable refer to Figure 6 57 PC X Connection Figure 6 56 IP...

Страница 470: ...onal Equipment 15 Install the NEC provided power cable refer to Figure 6 58 DC Power Connection 16 Connect the Core then plug in the Network connection cable refer to Figure 6 59 LAN Connection Figure...

Страница 471: ...optional external AC adapter refer to Figure 6 60 AC to DC In Connection The AC Adapter AC L UNIT must be ordered separately 18 Cable installation for the GBA L UNIT complete refer to Figure 6 61 GBA...

Страница 472: ...art outlines the connectivity available to the GBA L UNIT 11 6 3 LED Display The following provides a list of each LED and associated operation and status indications Refer to Figure 6 63 GBA L UNIT L...

Страница 473: ...4COTA Blade provides 2 Power Failure Transfer circuits The CN3 and CN5 connectors each provide connection to four analog trunk ports which are polarity sensitive tip to tip ring to ring The power fai...

Страница 474: ...un one pair 24 AWG station cable from the cross connect block to a modular jack 4 Terminate the extension leads to GRN RED of the modular jack Terminate the unused leads to the jack Refer to Figure 6...

Страница 475: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 6 63 Figure 6 64 Power Failure Connector CN3 Shown on GCD 4COTA Blade...

Страница 476: ...Issue 1 2 UNIVERGE SV9100 6 64 Installing SV9100 Optional Equipment...

Страница 477: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...