UNIVERGE SV9100
Issue 1.2
System Hardware Manual
6 - 15
S
ECTION
5
E
XTERNAL
P
AGING
5.1
External Page
Two external page zone/door box circuits are provided by each PGD(2)-U10
ADP installed. Each Door Box/external page circuit provides a dry relay
contact. The GCD-CP10 also provides a connection for external paging and a
relay. The external page on the GCD-CP10 is speaker number 9 - the relay is
number 0. The external page speakers provided by the PGD(2)-U10 ADPs are
1-8 – the relays on the PGD(2)-U10 ADPs are numbered 1~8.
The PGD(2)-U10 ADP can be used for talkback with External Page, as can a
CO trunk port with the proper external page equipment (ex: Valcom) – set
Program 31-06-03 to “0” for talkback. However, the external page circuit on
the GCD-CP10 cannot be used for talkback.
5.2
Installing an External Page System
1.
Connecting to the GCD-CP10:
Connect an RCA line from the CN8 or CN9 connector on the GCD-CP10
to the appropriate location on the extension cross-connect block.
2.
Connect the two-conductor station cable from the cross-connect block to
the external relay/external page.
3.
Install bridging clips as required.
OR
1.
Connecting to the PGD(2)-U10 ADP:
Make sure the jumper in the PGD(2)-U10 ADP for the channel is set
correctly. (Refer to Figure 6-4
PGD(2)-U10 ADP Jumper Settings
on
page 6-4).
2.
If a line cord was not previously connected to the PGD(2)-U10 ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a
modular jack. Ground the unused pair.
A PGD(2)-U10 ADP circuit used for External Paging
cannot also be used for an analog Door Box.
Содержание Univerge SV9100
Страница 1: ...System Hardware Manual Issue 1 2 January 2015...
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 40: ...Issue 1 2 UNIVERGE SV9100 1 16 Introduction to SV9100...
Страница 44: ...Issue 1 2 UNIVERGE SV9100 2 4 SV9100 System Specifications Figure 2 1 SV9100 System Block Diagram...
Страница 100: ...Issue 1 2 UNIVERGE SV9100 3 28 Installing the SV9100 Chassis Figure 3 36 Anchor Bolt from Wall 9 5 Chassis...
Страница 105: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 3 33 Figure 3 42 Brackets Small Batt Box...
Страница 154: ...Issue 1 2 UNIVERGE SV9100 3 82 Installing the SV9100 Chassis...
Страница 185: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 31 Figure 4 8 Connecting a IPLA Daughter Board to a Network PC...
Страница 199: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 45 Figure 4 12 Installing the GPZ 4LCA Daughter Board...
Страница 239: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 85 Figure 4 24 Control Signal Connection...
Страница 259: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 105 NOTES...
Страница 260: ...Issue 1 2 UNIVERGE SV9100 4 106 Installing the SV9100 Blades...
Страница 325: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 5 65 Figure 5 57 Sticker Braille L KIT Sheet 2...
Страница 412: ...Issue 1 2 UNIVERGE SV9100 5 152 Installing DT Series Digital and IP Multiline Terminals...
Страница 418: ...Issue 1 2 UNIVERGE SV9100 6 6 Installing SV9100 Optional Equipment Figure 6 5 PGD 2 U10 ADP Connection Diagram...
Страница 425: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 6 13 Figure 6 11 Setting the PGD 2 U10 ADP for a Door Box...
Страница 426: ...Issue 1 2 UNIVERGE SV9100 6 14 Installing SV9100 Optional Equipment Figure 6 12 Installing a Door Box...
Страница 438: ...Issue 1 2 UNIVERGE SV9100 6 26 Installing SV9100 Optional Equipment Figure 6 17 PGD 2 U10 ADP Connections...
Страница 475: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 6 63 Figure 6 64 Power Failure Connector CN3 Shown on GCD 4COTA Blade...
Страница 476: ...Issue 1 2 UNIVERGE SV9100 6 64 Installing SV9100 Optional Equipment...
Страница 477: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...