840Di-specific data and functions
18.2 Expanded message frame configuration/evaluation of internal drive variables
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
591
3'$IRUH[SDQGHGPHVVDJHIUDPH
3'$6WDQGDUG
PHVVDJHIUDPH
3'$$GGLWLRQDO
GULYHGDWD
%LW %LW
%LW %LW
%LW %LW
%LW %LW
,QGH[Q \
,QGH[Q [
,QGH[Q
,QGH[Q [
6\VWHPYDULDEOH9$B'3B$&7B7(/>QD@
3'$[
3'$[
3'$\
3'$
3'$[
3'$[
3'$\
3'$
Figure 18-2 Mapping principle: PDA on system variable $VA_DP_ACT_TEL
NOTICE
The responsibility for possibly necessary format conversions or correct interpretation of the
physical unit and significance of a system variable used in part programs or synchronized
actions lies exclusively with the user. Due to system restrictions, it is not possible for the
NC to perform a consistency check.
18.2.2
Requirements
The following conditions must be fulfilled for the transfer of additional drive variables:
●
Drive
The drive must support SIEMENS message frame 116 or free message frame
configuration.
●
DP master/SIMATIC STEP 7
No additional requirements
●
SINUMERIK 840Di sl NC
–
The option must be avaliable:
"Evaluation of internal drive variables",
Order No. (MLFB): 6FC5 251-0AB17-0BA0
–
The NC machine data should be set:
MD36730 $MA_DRIVE_SIGNAL_TRACKING[n] (acquisition of additional drive actual
values)
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...