Alarm and message texts
12.3 User text files
Manual
496
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Note
If the text file MYPLC_GR.COM is created on an external PC and then read in through the
serial interface (e.g. with PCIN), the following lines must be contained at the beginning of the
file:
%_N_MYPLC_GR_COM
;$Path=/_N_MB_DIR
MYPLC_GR.COM: user-spec. File for internal German PLC alarm texts
%_N_MYPLC_GR_COM
;$Path=/_N_MB_DIR
700000 0 0 "DB2.DBX180.0 set"
700001 0 0 "Lubrication pressure missing"
....
MBDDE.INI:
[Textfiles]
UserPLC= <Installationspfad>\dh\mb.dir\myplc_
NOTICE
Any modifications to alarm texts come only into effect after the appropriate user interface
has been rebooted.
When creating text files, make sure that the date and time are correctly set on the PCU.
Otherwise, the user texts may not appear on screen.