Ethernet communication
7.7 HT 2
Manual
224
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Signals from HT 2
acknowledg
ment
display
switch
E
D
C
B
A
1) Refer to Chapter: Rotary coding switch (Override)
- unassigned signals
Note
Unassigned signals are transferred from HT 8 with 0.
Output image
The address specification of the output image EB takes place in the FB 1 function module,
parameters: "HHUOut".
Table 7-9
Assignment of the signals in the output image
Signals to HT 2
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
AB m + 0
1)
-
-
-
-
-
-
-
AB m + 1
Requireme
nt. Write
display-line
-
-
-
-
-
Selection
Display-like
1 - 4
Bit 1
Selection
Display-like
1 - 4
Bit 0
AB m + 2
LED8
LED14
LED7
LED5
LED4
LED3
LED13
LED2
AB m + 3
LED15
LED12
LED20
LED19
LED18
LED17
LED10
LED9
1. Character of the selected line (outermost right character)
AB m + 4
2. Character of the selected line
AB m + 5
AB m + ...
. . . . . . .
15. Character of the selected line
AB m + 18
16. Character of the selected line (outermost left character)
AB m + 19
1) The output mode of the HT 2 display is adjusted via the output signal. The output signal must always be set to the value
1.
- unassigned signals
Note
The LED belonging to the output signal on HT 2 illuminates when the output signal has the value 1.
Unused output signals are to be set to 0.
NOTICE
Output signal AB m + 0, Bit 7
The output mode of the HT 2 display is adjusted via the output signal. The output signal
must always be set to the value 1.
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...