Axis and Spindle Test Run
13.1 Requirements
Manual
502
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
13.1.2
Drives: SIMODRIVE
Relevant terminals
Applies to the following SIMODRIVE drives:
●
SIMODRIVE 611 universal/universal E
●
SIMODRIVE POSMO SI, CD/CA
The following terminals must be connected:
I/RF module
Terminal
Description
63
Pulse enable
64
Drive enable
48
DC-link start
Drive Module
Terminal
Description
663
Pulse enable
Signal TRUE: +24 V (e.g. from terminal 9)
References:
/FBU/ Function Manual SIMODRIVE 611 universal
/POS3/ User Manual - SIMODRIVE SI/CD/CA
13.1.3
NC/PLC interface signals
Relevant NC/PLC interface signals
The following NC/PLC interface signals must be set:
DB number
Byte.Bit
Value
Description
31, ...
0
<> 0%
Feedrate/spindle override
31, ...
1.3
FALSE
Axis/spindle disable
31, ...
1.4
FALSE
Follow-up mode
31, ...
1.5
TRUE
Position measuring system 1
1)
31, ...
1.6
TRUE
Position measuring system 2
1)
31, ...
1.7
TRUE
Override active
31, ...
2.1
TRUE
Controller enable
31, ...
2.2
FALSE
Distance-to-go/Spindle reset
31, ...
4.3
FALSE
Feed stop/spindle stop
31, ...
4.4
FALSE
Traversing-key lock
31, ...
4.6
3)
Traversing key -
31, ...
4.7
3)
Traversing key +
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...