PLC commissioning
6.3 Creating a SIMATIC S7 project
Manual
168
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Dialog
Dialog: MPI/DP Properties
Tab: General
Name: <Designation of 2nd DP interface>
Group: Interface
Type: PROFIBUS
Button: "Properties..."
Dialog: Properties - PROFIBUS interface MPI/DP
Tab: Parameter
address: <Address>
Button: "New..."
Dialog: Properties - New Subnet PROFIBUS
Tab: Network settings
Data transfer rate: <Data transfer rate>
Profile: DP
OK
Tab: Mode
Radio button: <Mode>
OK
OK
NOTICE
If the interface X102 is not networked with PROFIBUS, then it must at least be networked
with MPI, in order to enable the internal communication via SOFTMC. See Subsection
"Parameterizing the MPI interface (X102) (optional)" (Page 169)