Hardware Descriptions
2.2 MCI2 board for 840Di sl
Manual
50
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
NOTICE
The PROFIBUS DP (X101) and MPI/DP bus (X102) interfaces are isolated both from
one another and from the PCU.
Backup voltage connection (X3)
Interface description of the backup voltage connection (X3):
●
Connection: 2-pin plug connector
●
Pin assignment
Table 2-4
Pin assignment: Backup voltage connection (X3)
Pin
Description
Type 1)
Function
1
BATT-
VI
Backup voltage minus
2
BATT+
VI
Backup voltage plus
1) VI: Voltage input
Diagnostic LEDs (DP1/DP2)
The diagnostics LEDs "DP 1" und "DP 2" are only used to display the internal status of the
MCI board. A diagnosis with regard to the PROFIBUS DP communication of the interfaces is
not possible via the LEDs.
2.2.3
Replace module
License key
If the MCI board is to be inserted as a replacement (either only the MCI board or together
with the PCU), you will need a new license key.
Consult the central hotline. You will need the:
●
HW series number of the old MCI board
●
HW series number of the new MCI board
The HW series number of the MCI board is to be found on the rating plate of the module
(see Fig. ).
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...